Westgate YM2108-T-W Vacancy and Occupancy Sensor Wall Switch

1. Introduzione

Thank you for choosing the Westgate YM2108-T-W Vacancy and Occupancy Sensor Wall Switch. This device is designed to enhance energy efficiency and convenience by automatically controlling lighting based on room occupancy. It is suitable for various applications, including bathrooms, garages, laundry rooms, and utility areas.

2. Informazioni di sicurezza

ATTENZIONE: To avoid fire, shock, or death; turn off power at circuit breaker or fuse box and test that power is off before wiring! This device requires a neutral wire for proper operation. If you are unsure about any part of these instructions, consult a qualified electrician.

  • Scollegate sempre l'alimentazione prima di l'installazione o di a manutenzione.
  • Assicuratevi chì tutti i cunnessione di i fili sianu sicuri è conformi à i codici elettrici lucali.
  • This product is UL Listed and Title-24 Compliant, ensuring it meets safety and energy efficiency standards.
  • Do not use with loads exceeding the specified ratings.

3. Produttu Finituview

The Westgate YM2108-T-W is a versatile wall switch that can function as either a vacancy sensor or an occupancy sensor, providing flexible lighting control. Its decorative style blends seamlessly with most interiors.

Westgate YM2108-T-W Vacancy and Occupancy Sensor Wall Switch

Figura 1: Fronte view of the Westgate YM2108-T-W Vacancy and Occupancy Sensor Wall Switch. The switch is white with a clear sensor lens at the top and a solid white lower section, mounted within a standard white wall plate.

Funzioni chjave:

  • Automatically turns lights on or off based on motion detection.
  • Functions as both an occupancy (auto-on/auto-off) and vacancy (manual-on/auto-off) sensor.
  • Replaces standard single-pole or 3-way switches.
  • Adjustable time delay from 1 minute to 30 minutes.
  • Adjustable light level sensitivity.
  • Compatible with incandescent, fluorescent, low voltage, electronic, and magnetic loads, including bathroom fans.
  • UL Listed and Title-24 Compliant.

4. Setup è Installazione

Before beginning installation, ensure power is OFF at the circuit breaker. This sensor requires a neutral wire connection. If your existing switch box does not have a neutral wire, consult a qualified electrician.

  1. Spegne l'alimentazione: Truvate l'interruttore automaticu chì cuntrolla l'interruttore chì state rimpiazzendu è spegnetelu. Verificate chì l'alimentazione sia spenta aduprendu un vol.tagè testatore.
  2. Eliminate u vechju interruttore: Carefully remove the existing wall plate and unscrew the old switch from the wall box. Disconnect the wires from the old switch, noting their connections.
  3. Identificà i fili: Identify the Line (hot), Load, Neutral, and Ground wires in the wall box. The Westgate YM2108-T-W typically has five wires: Line, Load, Neutral, Ground, and a Traveler wire for 3-way applications.
  4. Cunnessioni di filu: Connect the wires from the wall box to the corresponding wires on the Westgate sensor using wire nuts.
    • Cunnette u Linea wire to the sensor's Line wire.
    • Cunnette u Carica wire to the sensor's Load wire.
    • Cunnette u Neutrali wire to the sensor's Neutral wire.
    • Cunnette u Terra wire to the sensor's Ground wire.
    • For 3-way applications, connect the Viaggiatore wire to the sensor's Traveler wire and to the corresponding traveler wire on the other 3-way switch. For single-pole applications, cap off the traveler wire.
  5. Montà u sensoru: Carefully push the wired sensor into the wall box and secure it with the provided screws.
  6. Installa a placa murale: Attaccate a nova piastra murale.
  7. Ripristina l'energia: Riavvitate a corrente à l'interruttore automaticu.

5. Operating Instructions

The Westgate YM2108-T-W sensor offers flexible operation modes and adjustable settings.

Modi operativi:

  • Occupancy Mode (Auto-ON/Auto-OFF): In this mode, the lights will automatically turn ON when motion is detected and turn OFF after the set time delay when no motion is detected.
  • Vacancy Mode (Manual-ON/Auto-OFF): In this mode, the lights must be manually turned ON by pressing the switch. They will then automatically turn OFF after the set time delay when no motion is detected. This mode is Title 24 compliant.

The mode can typically be selected via a small switch or setting on the device itself, often accessible by removing the wall plate or a small cover.

Impostazioni aghjustabili:

  • Ritardo di tempu: Adjust the time the lights remain ON after the last detected motion. This can typically be set from 1 minute to 30 minutes. Locate the adjustment dial or switch on the sensor and set it to your desired duration.
  • Light Level Sensitivity (Photocell): This setting determines at what ambient light level the sensor will allow the lights to turn on (primarily in Occupancy mode). If the room is already bright enough, the sensor can be set to prevent lights from turning on. Adjust this setting to suit your environment.

6. Mantenimentu

The Westgate YM2108-T-W sensor is designed for minimal maintenance. To ensure optimal performance and longevity:

  • Pulizia: Periodically wipe the sensor lens and outer surface with a soft, dry cloth. Do not use abrasive cleaners, solvents, or excessive moisture, as these can damage the device.
  • Ispezione: Occasionally inspect the wall plate and sensor for any signs of damage or loose connections.

No user-serviceable parts are inside. Refer all servicing to qualified personnel.

7. Risoluzione di prublemi

If you experience issues with your Westgate YM2108-T-W sensor, refer to the following common problems and solutions:

PrublemuCausa PossibileSoluzione
Lights do not turn ON automatically.
  • Incorrect operating mode (Vacancy mode selected).
  • Light level sensitivity set too high (photocell prevents activation).
  • Nisuna alimentazione à l'interruttore.
  • Errore di cablaggio.
  • Sensore ostruitu o fora di portata.
  • Switch to Occupancy mode if auto-ON is desired.
  • Adjust light level sensitivity setting.
  • Verificate l'interruttore automaticu è i cunnessione di i fili.
  • Verify all wires are connected correctly, especially Line and Neutral.
  • Ensure sensor is not blocked and motion is within detection range.
I luci ùn si spenghjenu micca.
  • Muvimentu custante rilevatu.
  • U ritardu di tempu hè statu impostu troppu longu.
  • Wiring error (e.g., Load wire connected incorrectly).
  • Sensore difettu.
  • Ensure no continuous motion is within the sensor's view.
  • Ajustà u ritardu di tempu à una durata più corta.
  • Verify Load wire connection.
  • If issues persist after checking other points, contact support.
Sensor is unresponsive.
  • Nisun putere.
  • Connessioni di cablaggio solte.
  • Incorrect wiring (e.g., missing neutral).
  • Verificate u circuit breaker.
  • Turn off power and re-secure all wire nuts.
  • Ensure neutral wire is correctly connected.

8. Specificazioni

AttributuDetail
MarcaWestgate
Numero di mudelluYM2108-T-W
U fabricatoreWestgate Manufaturing
Fonte d'energiaCorded Electric
Tipu di muntaturaMuntu à u muru
CuloreBiancu
Dimensioni di u pacchettu4.7 x 2.9 x 2.3 inch
Pesu di l'articulu5.6 once
Descrizzione di batterieBatteria micca inclusa
CunfurmitàUL Listed, Title-24 Compliant

9. Garanzia è Support

For warranty information and technical support regarding your Westgate YM2108-T-W Vacancy and Occupancy Sensor Wall Switch, please contact Westgate Manufaturing directly. Retain your proof of purchase for warranty claims.

Per più assistenza, pudete visità u Westgate Store on Amazon.