Rigol DHO914

Manuale d'usu di l'oscilloscopiu digitale RIGOL DHO914

Model: DHO914

1. Introduzione

This manual provides essential instructions for the safe and efficient use of the RIGOL DHO914 Digital Oscilloscope. The DHO914 is a 4-channel oscilloscope featuring a 125 MHz bandwidth, 1.25 GSa/s sampling rate, 12-bit analog-to-digital converter, 50 Mpts memory depth, and a 7-inch 1024x600 pixel touchscreen display. Please read this manual thoroughly before operating the device.

2. Informazioni di sicurezza

Observe the following safety precautions to prevent injury and avoid damage to the instrument or any products connected to it. This device is designed for use by qualified personnel only.

  • Fonte di energia: Use only the power cable supplied with the instrument and ensure it is connected to a grounded power outlet.
  • Ventilazione: Assicurà una ventilazione adatta. Ùn bluccà micca l'aperture di ventilazione.
  • Ambiente: Operate the instrument in a dry environment, away from moisture, dust, and direct sunlight.
  • Sonde: Aduprate solu sonde classificate per u vulumetage and current being measured. Ensure probes are properly connected before making measurements.
  • Pulizia: Scollegate l'alimentazione prima di pulisce. Aduprate un panu dolce èamp pannu; ùn aduprate micca detergenti abrasivi o solventi.
  • Service : Ùn pruvate micca di fà a riparazione di u strumentu da per voi. Affidate tutta a manutenzione à u persunale di assistenza qualificatu.

3. Setup

3.1 Unpacking è Inspection

Carefully unpack the oscilloscope and check for any signs of damage during transit. Retain the packaging materials for future transport or storage.

3.2 Ciò chì hè in a scatula

Contents of the RIGOL DHO914 Oscilloscope box, including the main unit, power adapter, USB cable, ground wire, passive probes, and warranty card.

Figura 3.2.1: Contents of the RIGOL DHO914 Oscilloscope box. The image displays two packaging boxes, the main oscilloscope unit, an EU power adapter, a USB A-B cable, a ground wire, four passive probes (150MHz), and a warranty card with calibration certificate.

The standard package for the RIGOL DHO914 includes:

  • Main Unit (RIGOL DHO914 Digital Oscilloscope)
  • Power Cable (EU Power Adapter)
  • USB Cable (USB A-B Cable)
  • Filu di Terra
  • Passive Probes (4 units, 150MHz)
  • Warranty Card & Calibration Certificate

3.3 Product Overview

Front, back, side, and button views of the RIGOL DHO914 Digital Oscilloscope, showing its physical dimensions and interfaces.

Figura 3.3.1: RIGOL DHO914 Physical Overview. This image illustrates the front panel with its 7-inch display and control buttons, the rear panel with various ports, a side view showing its slim profile, and a detailed view of the control buttons. Dimensions are indicated as 265.36mm length, 77.38mm width, and 161.75mm height, with a weight of 1.78kg.

The DHO914 features a compact design with a 7-inch high-definition touchscreen. The front panel includes the display, control knobs, and buttons for various functions. The rear panel provides connectivity options such as USB Device&Host, LAN, and HDMI ports. The device measures approximately 26.53 cm (Length) x 7.74 cm (Width) x 16.17 cm (Height) and weighs 1.78 kg.

3.4 Cunnessione iniziale

  1. Connect the power cable to the oscilloscope's power input and then to a grounded AC power outlet.
  2. Appughjà u buttone di putenza situatu nantu à u pannellu frontale per accende u dispusitivu.
  3. Connect the passive probes to the analog input channels (CH1, CH2, CH3, CH4) as needed for your measurements. Ensure the probe compensation is correctly adjusted for accurate readings.
  4. Optionally, connect USB devices, LAN cables, or an HDMI display to the respective ports for extended functionality.

4. Operating Instructions

4.1 Funzionamentu di basa

Upon powering on, the oscilloscope will display the main measurement interface. The 7-inch touchscreen allows for intuitive navigation and parameter adjustment. Alternatively, use the physical buttons and knobs for precise control.

Fronte view of the RIGOL DHO914 Digital Oscilloscope highlighting its 125 MHz bandwidth, 12-bit resolution, 1.25 GSa/s sampling rate, 50 Mpts storage depth, USB, LAN, HDMI interfaces, and 7-inch 1024x600 HD touch display.

Figura 4.1.1: RIGOL DHO914 Main Features. This image shows the oscilloscope's front panel with key specifications overlaid, including 125 MHz bandwidth, 12-bit resolution, 1.25 GSa/s sampling rate, 50 Mpts storage depth, and available interfaces (USB, LAN, HDMI), all controlled via a 7-inch 1024x600 HD touch display.

4.2 Caratteristiche è funzioni principali

  • Alta risoluzione: The 12-bit hardware resolution ensures precise signal capture, even for small signals, due to its ultra-low background noise.
  • Bandwidth and Channels: Features 125 MHz analog bandwidth across 4 analog channels. An optional 16 digital channels are available for mixed-signal analysis.
  • Sampling Rate and Memory: Offers a real-time sampling rate of up to 1.25 GSa/s and a deep memory of 50 Mpts, allowing for detailed capture of long signal sequences.
  • Frequenza di cattura di forma d'onda: The Ultra Aqua mode provides a waveform capture rate of up to 1,000,000 wfm/s, increasing the probability of capturing infrequent events.
  • Schermu è Interfaccia: The 7-inch 1024x600 HD touchscreen supports 256-level grayscale real-time brightness, enhancing waveform visualization. The new Flex button provides an intuitive user experience.
  • Integrated Analysis Functions: The oscilloscope integrates various analysis tools, including an arbitrary waveform/function generator, birdon trace analysis, histogram, and digital signal analysis.
  • Connettività: Standard USB Device&Host, LAN, and HDMI ports facilitate data transfer, remote control, and external display connections.
  • Waveform Search and Navigation: Utilize the built-in search and navigation functions to quickly identify anomalies within captured waveforms.

5. Mantenimentu

5.1 Pulizia

To clean the instrument, disconnect it from the power source. Use a soft cloth dampened with a mild detergent solution. Do not use abrasive cleaners, solvents, or harsh chemicals, as these may damage the casing or display. Ensure no liquid enters the instrument.

5.2 Storage

When not in use for extended periods, store the oscilloscope in a dry, dust-free environment, preferably in its original packaging or a protective case. Avoid extreme temperatures and humidity.

6. Risoluzione di prublemi

Questa sezione furnisce suluzioni à i prublemi cumuni. Per i prublemi chì ùn sò micca elencati quì, cuntattate l'assistenza clienti.

PrublemuCausa PossibileSoluzione
U strumentu ùn s'accende micca.Power cable not connected, power outlet faulty, power button not pressed.Check power cable connection. Verify power outlet functionality. Press the power button firmly.
Nisuna forma d'onda hè visualizata.Probe not connected, signal source off, vertical scale too high/low, trigger settings incorrect.Ensure probes are connected to the signal source and oscilloscope. Verify signal source is active. Adjust vertical scale (V/div) and horizontal scale (s/div). Check trigger level and mode.
Waveform is unstable or noisy.Poor probe connection, ground loop, external interference, incorrect probe compensation.Ensure secure probe connections. Use proper grounding techniques. Minimize external electromagnetic interference. Perform probe compensation adjustment.
U touchscreen ùn risponde micca.Problema tempurale di u software, schermu sporcu.Restart the instrument. Clean the screen with a soft, dry cloth. If the issue persists, use physical controls or contact support.

7. Specificazioni

The following table outlines the key technical specifications for the RIGOL DHO914 Digital Oscilloscope.

Technical specifications table for the RIGOL DHO914 Digital Oscilloscope, listing bandwidth, channels, sample rate, memory depth, waveform capture rate, vertical resolution, minimum vertical sensitivity, minimum timebase, decode types, and built-in signal generator status.

Figura 7.1.1: RIGOL DHO914 Technical Data. This image presents a table detailing the oscilloscope's specifications: Bandwidth: 125 MHz, No. Channels: 4A+16D Logic Analyzer, Sample Rate: 1.25G Sa/s, Memory Depth: 50 Mpts, Waveform capture rate: 1,000,000 wfms/s, Vertical Resolution: 12 bit, Min. Vertical Sensitivity: 500uV/div, Min. Timebase: 2 ns/div, Decode Types: RS232/I2C/SPI/CAN/LIN, Built-in Signal Generator: Not supported.

ParametruSpecificazione
larghezza di banda125 MHz
Numero di canali4 Analog + 16 Digital (Logic Analyzer)
Sample Rate1.25 GSa/s
Prufundità di memoria50 Mpts
Frequenza di cattura di forme d'onda1,000,000 wfms/s (Ultra Aqua mode)
Risoluzione Verticale12-bit
Min. Vertical Sensitivity500 µV/div
Min. Timebase2 ns/div
Decode TypesRS232, I2C, SPI, CAN, LIN
Generatore di signali integratuÙn hè micca supportatu
Mostra7-inch (1024x600) HD Touchscreen
ConnettivitàUSB Device&Host, LAN, HDMI
Dimensioni (L x W x H)26.53 x 7.74 x 16.17 cm (10.5 x 3.0 x 6.4 inch)
Pesu1.78 kg (3.9 lbs)
Fonte d'energiaWired-electric

8. Garanzia è Support

8.1 Garanzia infurmazione

The RIGOL DHO914 Digital Oscilloscope comes with a standard 3 anni di garanzia from the date of purchase. This warranty covers defects in materials and workmanship under normal use. Please refer to the included Warranty Card for detailed terms and conditions.

8.2 Assistenza Clienti

For technical assistance, troubleshooting beyond this manual, or warranty claims, please contact RIGOL customer support. You can find contact information on the official RIGOL website or through your local distributor. Ensure you have your product model number (DHO914) and serial number ready when contacting support.

9. Applicazioni tipichi

The RIGOL DHO914 Digital Oscilloscope is suitable for a wide range of applications due to its high performance and versatile features.

Collage of application scenarios for the RIGOL DHO914 Digital Oscilloscope, including embedded development, factory production lines, instrument maintenance, education and research, and automotive manufacturing.

Figura 9.1.1: RIGOL DHO914 Application Scenarios. This image displays various environments where the oscilloscope can be utilized, such as embedded development, factory production lines, instrument maintenance, educational and research settings, and automotive manufacturing.

  • Embedded Development: For debugging and testing embedded systems.
  • Factory Production Line: Quality control and signal integrity checks in manufacturing.
  • Manutenzione di l'instrumentu: Diagnostics and repair of electronic equipment.
  • Education and Research: Ideal for laboratory experiments and academic studies.
  • Automotive Manufacturing: Analyzing signals in automotive electronic systems.

© 2023 RIGOL. All rights reserved. Information in this document is subject to change without notice.

Documenti cunnessi - DHO 914

Preview MHO98 Digital Oscilloscope User Guide
Comprehensive user guide for the RIGOL MHO98 Digital Oscilloscope, covering safety, setup, operation, and advanced measurement features.
Preview Guida rapida di l'osciloscopiu digitale RIGOL DHO900 Series
Get started quickly with the RIGOL DHO900 Series Digital Oscilloscope. This guide covers essential safety information, product overview, setup, basic operations, and remote control for models DHO914, DHO914S, DHO924, and DHO924S.
Preview Guida rapida di l'osciloscopiu digitale RIGOL DHO900 Series
Questa guida rapida furnisce l'infurmazioni essenziali per l'osciloscopiu digitale RIGOL DHO900 Series, chì coprenu i requisiti di sicurezza, l'ispezione generale, u pruduttu.view, preparazione per l'usu, gesti di u schermu tattile è metudi di impostazione di i parametri.
Preview Guida rapida di l'osciloscopiu digitale RIGOL DHO900 Series
Guida rapida per l'osciloscopiu digitale RIGOL DHO900 Series, chì copre i requisiti di sicurezza, u pruduttu sopraview, preparazione per l'usu è operazioni basiche.
Preview Scheda tecnica di l'oscilloscopiu digitale RIGOL MHO98 - Apparecchiatura di prova ad alte prestazioni
Scheda tecnica dettagliata per l'osciloscopiu digitale RIGOL MHO98 Special Edition, cù una larghezza di banda di 1 GHz, 4 GSa/ssample rate, 12-bit resolution, 500 Mpts memory, and a 7-inch touch screen. Includes specifications, features, applications, and accessories.
Preview Guida di prugrammazione di l'osciloscopiu digitale di a serie RIGOL DHO800/DHO900
Questa guida di prugrammazione furnisce infurmazioni dettagliate nantu à i cumandamenti SCPI per cuntrullà l'osciloscopi digitali di e serie RIGOL DHO800 è DHO900 via interfacce USB è LAN.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.