TOCT1-25Z

Generic TOCT1-25Z Din Rail Modular Contactor Instruction Manual

Models: TOCT1-25Z (DC 12V Coil, DC 24V Coil)

1. Introduzione

This manual provides essential information for the safe installation, operation, and maintenance of the Generic TOCT1-25Z Din Rail Modular Contactor. This device is designed for reliable AC power switching in various applications, controlled by a DC 12V or 24V coil.

Please read this manual thoroughly before installation and operation to ensure proper use and to prevent potential hazards.

2. Informazioni di sicurezza

WARNING: Electrical shock hazard. Installation and maintenance should only be performed by qualified personnel. Disconnect all power before working on the contactor or associated circuits.

  • Ensure proper wiring and polarity as indicated on the device.
  • Ùn supere micca u volu specificatutage e valutazioni attuali.
  • Prutegge u dispusitivu da l'umidità, a polvera è e temperature estreme.
  • Always follow local electrical codes and regulations during installation and operation.
  • Never attempt to repair a damaged contactor; replace it with a new one.

3. Caratteristiche di u produttu

  • Precision Electrical Control: Ensures reliable power switching for HVAC systems and industrial equipment with smooth operation.
  • Durable Silver Alloy Contacts: Provides superior conductivity and arc resistance for extended product lifespan.
  • Universal Voltage Compatibilità: Works with 24V/120V/208V systems (main circuit) and DC 12V/24V coil control for flexible installations.
  • Alloghju resistente à l'intemperie: Protects internal components from moisture, dust, and temperature fluctuations.
  • Terminali à cunnessione rapida: Simplified wiring with clearly marked screw terminals for hassle-free maintenance.
  • Funzionamentu silenziu: Operates at less than 15dB, ensuring minimal noise disturbance.

4. Setup è Installazione

The TOCT1-25Z modular contactor is designed for standard 35mm Din Rail mounting. Follow these steps for proper installation:

  1. Muntamentu: Securely attach the contactor to a standard 35mm Din Rail. Ensure it clicks firmly into place.
  2. TOCT1-25Z contactor mounted on a Din Rail

    Image: The TOCT1-25Z modular contactor shown mounted on a standard Din Rail, illustrating its compact design and secure attachment mechanism.

  3. Wiring the Coil (Control Circuit):
    • Identify the coil terminals, typically marked with '+' and '-' for DC voltage.
    • For DC 24V coil models, connect the DC 24V control voltage to the coil terminals.
    • TOCT1-25Z contactor with 24VDC coil wiring diagram

      Imagine: Un primu pianu view of the TOCT1-25Z contactor, highlighting the 24VDC coil input terminals and the internal wiring diagram. A warning about confirming polarity is visible.

    • For DC 12V coil models, connect the DC 12V control voltage to the coil terminals.
    • TOCT1-25Z contactor with 12VDC coil wiring diagram

      Imagine: Un primu pianu view of the TOCT1-25Z contactor, highlighting the 12VDC coil input terminals and the internal wiring diagram. A warning about confirming polarity is visible.

    • Impurtante: Observe correct polarity for DC coils. A warning label on the device indicates "Please confirm polarity before using!".
  4. Wiring the Main Circuit (Load):
    • Connect the AC load circuit to the main power terminals (e.g., 1, 3 for input and 2, 4 for output).
    • Assicuratevi chì tutte e cunnessione sianu strette è sicure per impedisce cuntatti allentati è surriscaldamentu.
    • Verify that the main circuit voltage and current do not exceed the contactor's ratings (e.g., 25A, 250V/500V).
  5. Verificazione finale: Before applying power, double-check all wiring for correctness and security.

5. Operating Instructions

The TOCT1-25Z modular contactor operates by energizing its DC coil, which then closes or opens the main AC contacts to control the connected load.

  • Attivazione: When the specified DC control voltage (12V or 24V) is applied to the coil terminals, the contactor will activate, changing the state of its main contacts (e.g., 2NO contacts will close, 1NO 1NC will have NO close and NC open).
  • Disattivazione: Eliminazione di u cuntrollu voltage from the coil terminals will deactivate the contactor, returning the main contacts to their original state.
  • Indicazione di Status: The contactor features a disconnection display, where an indicator light provides clear visual feedback on its operational status (open or closed).
  • TOCT1-25Z contactor with breaking instructions and indicator light

    Image: The TOCT1-25Z contactor with a visual representation of its "Breaking Instructions," showing how the indicator light clearly displays the disconnection status.

  • Prestazione tranquilla: The contactor is designed for very quiet operation, with noise levels typically less than 15dB, making it suitable for household and noise-sensitive environments.
  • TOCT1-25Z contactor with 'Very Silent Less Than 15dB' text and sleeping baby

    Image: A visual emphasizing the quiet operation of the TOCT1-25Z contactor, stating "VERY SILENT LESS THAN 15DB," suitable for environments requiring minimal noise.

6. Mantenimentu

The TOCT1-25Z modular contactor is designed for long-term, reliable operation with minimal maintenance. However, periodic checks are recommended:

  • Ispezione visuale: Ispettate regularmente u cuntatture per ogni segnu di danni fisichi, scolorimentu o cunnessione allentate.
  • Strettezza di u Terminale: Periodically check that all wiring terminals are securely tightened. Loose connections can lead to overheating and device failure.
  • Pulizia: If necessary, gently clean the exterior of the contactor with a dry, soft cloth. Do not use solvents or abrasive cleaners.
  • Cundizioni Ambientali: Ensure the operating environment remains within the specified temperature and humidity ranges to prevent premature wear.

CAUTION: Always disconnect power to the circuit before performing any inspection or maintenance.

7. Risoluzione di prublemi

Sè u cuntattore ùn funziona micca cum'è previstu, cunsiderate i seguenti prublemi è suluzioni cumuni:

Prublemu Causa Possibile Soluzione
Contactor does not activate when control voltage hè appiicata.
  • Nisun cuntrollu voltage.
  • Un cuntrollu incorrectu voltage (e.g., 12V coil with 24V).
  • Incorrect polarity for DC coil.
  • Loose coil wiring.
  • Bobina dannighjata.
  • Verificà u vulume di cuntrollutage presence and correct level.
  • Ensure correct coil voltage furnitura di partite.
  • Check and correct polarity.
  • Tighten coil connections.
  • Rimpiazzà u cuntatture se a bobina hè dannighjata.
Contactor activates but load does not receive power.
  • No power to main circuit.
  • Loose main circuit wiring.
  • Cuntatti principali dannighjati.
  • Verify power supply to the main circuit.
  • Tighten main circuit connections.
  • Rimpiazzà u cuntatture se i cuntatti sò dannighjati.
Contactor makes unusual noise or hums excessively.
  • Muntatura libera.
  • Foreign object interfering with armature.
  • Coil issue (e.g., incorrect voltage, damage).
  • Ensure contactor is securely mounted on Din Rail.
  • Inspeccione per ostaculi.
  • Verificate u vulume di a bobinatage and inspect for damage.

8. Specificazioni

Numero di mudellu TOCT1-25Z
Marca Generic
Tipu d'elettricità DC (for coil control), AC (for main circuit)
Coil Voltage Opzioni DC 12V, DC 24V
Main Circuit Rating Current (Ie) 25A
Main Circuit Rating Voltage (Ue) 250V / 500V
Nùmeru di Poli 2 (e.g., 2NO or 1NO 1NC configurations)
Tipu di muntatura Din Rail Mount
Livellu di Rumore Operativu Meno di 15 dB
Dimensioni (circa) 0.39 x 0.39 x 0.39 inch (Dimensioni di u pacchettu)
Pesu di l'articulu 3.53 once
Certificazione CE

9. Garanzia è Support

Per infurmazioni nantu à a garanzia è l'assistenza tecnica, vi pregu di cunsultà u rivenditore o u serviziu ufficiale di u fabricatore. websitu. Conservate a vostra ricevuta di compra per qualsiasi reclamu di garanzia.

Sè avete prublemi chì ùn sò micca trattati in questu manuale, cuntattate l'assistenza clienti per assistenza.