EVENT-LIGHTING-LOGO

EVENT LIGHTING APRO4-IP DMX Controller

EVENT-LIGHTING-APRO4-IP-DMX-Controller-PRODUCT-IMAGE

Per a vostra sicurità, leghjite attentamente stu manuale d'utilizatore prima di l'usu.
Event Lighting si riserva u dirittu di rivisà u manuale in ogni mumentu. L'infurmazioni è e specificazioni in stu manuale sò sottumessi à cambià senza avvisu. Event Lighting ùn assume alcuna responsabilità o rispunsabilità per eventuali errori o omissioni. Per piacè cunsultate Event Lighting per qualsiasi chiarificazione o infurmazione nantu à questu articulu.

CARATTERISTICHE

  • DMX 512, RDM, Artnet and sACN support
  • Configurazione remota via interna webpagina
  • Update firmware on Webpagina
  • DMX output isolation
  • RJ45 Ethernet B input with POE(DC12V 2A)
  • Display LCD
  • Gigabit network, 100/1000mbps port speed
  • Classificazione IP65

PANNELLU FINITUVIEW

EVENT-LIGHTING-APRO4-IP-DMX-Controller-IMAGE (1)EVENT-LIGHTING-APRO4-IP-DMX-Controller-IMAGE (2)

  1. Ethernet port RJ45
  2. Ethernet port RJ45
  3. Power in/out True1
  4. 2xDMX5pin connectors
  5. 2xDMX5pin connectors
  6. Porta fusible
  7. LCD Display protection cover

MENUS
Below is controller Menus map

PrincipaleMenu Sottomenu 1 Sottomenu 2 Valore/Opzione Default
Rete Modu IP DHCP Staticu
Staticu
Indirizzu IP 2.xx.xx.xx 2.xx.xx.xx
Maschera di Subnet 255.0.0.0 255.0.0.0
Port DMX Protocolu Artnet Artnet
sACN
Start Net 000-127 000
Start Universe 000-255 000
Portu 1 Modu Off On
On
NET 000-127 000
Universu 000-255 000
Portu 2 Modu Off On
On
NET 000-127 000
Universu 000-255 001
Portu 3 Modu Off On
On
NET 000-127 000
Universu 000-255 002
Portu 4 Modu Off On
On
NET 000-128 000
Universu 000-255 003
Disattivà
Settings Tariffa DMX 20 Hz 30 Hz
25 Hz
30 Hz
35 Hz
40 Hz
RDM Disattivà Disattivà
Attivà
Mustrà On Sempre 1 min
30 sec
1 min
5 min
Perdita di signale Mantene DMX Mantene DMX
Stop Output
Modu Merge PH PH
LTP
Reset di fabbrica Innò Innò

WEB cunfigurazione

NET device network IP mode can set to DHCP mode or Static mode.

Modu DHCP

  • When APRO4‐IP is set to DHCP mode, you need to set the computer to DHCP also. And use a router for linking computer and APRO4‐IP device. The controller will show IP address like below: EVENT-LIGHTING-APRO4-IP-DMX-Controller-IMAGE (3)
  • Enter IP address in your web browser, then you can login webpage to configure the parameter of controller. EVENT-LIGHTING-APRO4-IP-DMX-Controller-IMAGE (4)

Inserite password: admin

Modu staticu

  • When APRO4‐IP device is set to Static mode, you need to set computer to be Static mode also. APRO4‐IP device will show IP address as below: EVENT-LIGHTING-APRO4-IP-DMX-Controller-IMAGE (5)
  • Then set the IP address of computer is in the same IP range manually. For example: IP address must start with 2 according to APRO4‐IP address. And netmask is same with 255.0.0.0. EVENT-LIGHTING-APRO4-IP-DMX-Controller-IMAGE (6)
  • Input static IP address of APRO4‐IP device in your browser, then you can login to configure the parameter of device.

Inserite password: admin EVENT-LIGHTING-APRO4-IP-DMX-Controller-IMAGE (7)

  • When log on NET Config web, the first page show the information about APRO4‐IP. EVENT-LIGHTING-APRO4-IP-DMX-Controller-IMAGE (8)
  • Following  is  for  Network  setting,  you  can  set  IP  mode  to  be  Static  or  DHCP,  IP  Address,and Subnet Mask. After setting, click Save button . EVENT-LIGHTING-APRO4-IP-DMX-Controller-IMAGE (8)
  • For DMX Port page , it is used for DMX Port setting. You can select Protocol to be Artnet or sACN, and set each port as input or output. EVENT-LIGHTING-APRO4-IP-DMX-Controller-IMAGE (10)
  • On the page of Setting , you can set DMX Rate, RDM , Display On and Signal Loss. After setting, click Save to store the setting.
  • DMX  Rate:  You  can  set  20Hz,  25Hz,  30Hz,  35Hz,  40Hz,  30Hz  is default setting.
  • RDM: You can set RDM to be Disable or Enable.
  • There is 4 options for Display On mode: Always, 30Sec, 1Min, 5Min.
  • Perdita di signale: Can set as Hold DMX or Stop Output. EVENT-LIGHTING-APRO4-IP-DMX-Controller-IMAGE (11)
  • You can return to factory setting by click Factory Reset button. EVENT-LIGHTING-APRO4-IP-DMX-Controller-IMAGE (12)
  • On Update page, you can update software of fixture by selecting the update software file of APRO4‐IP.
  • On the last page, you can reset password. EVENT-LIGHTING-APRO4-IP-DMX-Controller-IMAGE (13)

SPECIFICATION

  • Potenza in: AC 100‐240V,50/60Hz
  • Cunsumu di energia: AC240V 50HZ 0.05A
  • Taglia: 215.3×150.5x42mm 4.2W
  • Pesu: 1.43 kg
  • POE 802.3af
  • IP65

DIMENSIONI

EVENT-LIGHTING-APRO4-IP-DMX-Controller-IMAGE (14)

Garanzia

Per piacè riferite à u vostru rivenditore lucali o cuntattate Event Lighting. www.event‐lighting.com.au

Domande Frequenti

How do I reset the APRO4-IP device to factory settings?

To perform a factory reset on the APRO4-IP device, access the Factory Reset option in the Main Menu under Settings. Confirm the reset to restore the device to its default configuration.

What is the default IP address for the APRO4-IP device?

The default IP address for the APRO4-IP device is set to DHCP mode. If you switch to Static mode, you can set a specific IP address within the range provided in the user manual.

Documenti / Risorse

EVENT LIGHTING APRO4-IP DMX Controller [pdfManuale d'usu
APRO4-IP, APRO4-IP DMX Controller, DMX Controller, Controller

Referenze

Lascia un cumentu

U vostru indirizzu email ùn serà micca publicatu. I campi obbligatori sò marcati *