MAPER-LOGO

MAPER Wiver High Performance Wireless Condition Monitoring Sensor

MAPER-Wiver-High-Performanc-Wireless-Condition-Monitoring-Sensor-PRODUCT

About MAPER
MAPER is a leading manufacturer of industrial condition monitoring solutions. Since 2015, we have focused on developing innovative wireless sensors and monitoring systems that help maintain asset reliability and optimize industrial operations. Our headquarters in Mexico City houses our R&D center and main manufacturing facility, where we design and produce the full range of MAPER monitoring solutions, including the Wiver sensor family and associated systems.

L'infurmazione di a cumpagnia
WIVER TECNOLOGIA INDUSTRIAL S.A. DE C.V.
LIBERTAD 118, PEDREGAL DEL CARRASCO, COYOACAN, 04700 CIUDAD DE MEXICO, MEXICO

Overview

WIVER is a high-performance wireless condition monitoring sensor. Coupled with MAPER’s Asset and Process Health Platform, it can provide smart insights on asset health by measuring tri-axial vibration and temperature. Its multiple configuration options allow condition monitoring of diverse machines, including highly intermittent assets which are difficult to diagnose with competing products. Multiple WIVERs can be automatically synchronized for simultaneous measurement of a given asset. MAPER offers multiple versions: WIVER standard (optimized for the most common assets in industry) and WIVER FS for highly intermittent machines. Each of these can also be configured according to the operation ambient rating: standard, HT (high temperature – up to 100°C continuous operation) and Ex for explosive atmospheres.

  • Easy installation in 15’.
  • NFC allows single-touch configuration using a cell phone.1
  • Multiple mounting options (adhesive base, mounting fins, screw mount, etc.)2
  • Highly configurable for diverse machine types
  • Periodic acceleration and velocity RMS value measurement
  • Periodic spectrum measurement
  • Magnetometer3 for diagnosing electrical faults.
  • Wireless synchronization
  • Long wireless range
  • Long battery life and easy battery replacement
  • Regular alkaline AA batteries for ease of procurement
  • Accurate timestamping allows event correlation with plant processes
  • Internal health monitoring4 tracks the sensor’s own condition.

MAPER-Wiver-High-Performanc-Wireless-Condition-Monitoring-Sensor (2)

  1.  2023Q2
  2. Contact MAPER Applications for more details.
  3. 2023Q2
  4. Contact MAPER Applications for more details.

Caratteristiche tecniche

Parametru Cundizione di prova Min Tipu Max Unità
Vibration – Wiver HF
Gamma ± 2 ± 16 g
Sampling frequency (fS) 0.2 26.67 kHz
Maximum spectral frequency (fMAX) 0.1 13.33 kHz
Spectral resolution (Df) 0.015 Hz
Sensitivity variation over temperature 0.013 0.025 % / ° C
Errore di sensibilità @ 50Hz -2 0 2 %
A precisione di frequenza -0.03 0.03 %
Larghezza di banda (-3 dB) Horizontal, Vertical, Axial 6300 Hz
Rumore 70 μg Hz-1/2
Spectral lines nisuna sovrapposizione 100 13333
Finestra Hann, Hamming, Flat-Top, Rectangular, B-H
Overlap 0 100 %
RMS report period 5 2 15 minuti
Spectral report period 5 2 6 ore
Temperature
Accuratezza6 -10 °C à 60 °C -3 3 °C
elsewhere -3.5 3.5 °C
Battery and power consumption
Tipu di batterie non-Ex version 2x AA (LR6) alkaline, 1.5V7
Ex versione 2x Energizer L91 (AA Lithium)8
 

Durata9

Applicazione #110 – non-Ex 36 mesi
Applicazione #211 – non-Ex 18 mesi
Application #1 – Ex 30 mesi
Application #2 – Ex 15 mesi
Environmental and mechanical
Temperature di funziunamentu -30 10012 °C
Classificazione IP IP68
Taglia Diamitru 50 mm
  • Low-RPM configuration, compatible with fMAX <= 200Hz. Standard configuration: f >= 1Hz for all fMAX. Contact MAPER for details. 6 Subject to mounting condition.
  • MAPER recommends Energizer E91 Max or Duracell MN1500.
  • Use only recommended battery make and model.
  • Duration is highly dependent on machine intermittency, measurement configuration (periodicity, type and length of measurement, synchronization configuration), proximity to MAPER Gateway, network load, RF environment, and other environmental conditions such as ambient temperature. MAPER defines duration based on standard applications.
  • Application #1: machine which runs 24/7, 4 synchronized Wiver sensors on the same machine, configured for rms measurements every 20’ and 1 spectrum every 4hs. Contact MAPER Applications for more details.
  • Application #2: machine which runs intermittently, 4 unsynchronized Wiver sensors on the same machine, configured for rms measurements every 15’ and 1 spectrum every 3hs. Contact MAPER Applications for more details.
  • Value for WIVER HT. For standard operating environment configuration, max ambient temperature is 60°C. Do not confuse ambient temperature with base temperature.
Lunghezza13 115 mm
Pesu14 341 g
Materiale di basa Inossidabile
Materiale di cunchiglia PP, translucid gray
Wireless
Gamma15 70 M
Operating frequency (TX and RX) 915 925 MHz
EIRP 50 mW
 

 

Protocollu di cumunicazione

  • Physical Layer: IEEE802.15.4-2015 O-QPSK PHY (DSSS modulation)
  • Modulazione: O-QPSK
  • Channel Bandwidth: 850kHz @ -6dB (ANSI C63.10-2020 11.8.1 Opt 1)
  • Spaziu di i canali: 2 MHz
  • Power Spectral Density: < -6 dBm/3kHz (ANSI C63.10-2020 11.10.3)
 

NFC

  • Dynamic NFC Tag type 5 (passive)
  • Protocol: ISO/IEC 15693
  • Frequenza Operativa: 13.56 MHz
  • Communication Range: Up to 1.5 cm
  • Data Rate: Up to 53 Kbit/s
Orologio in tempu reale
Timestamp precisione -3 3 s

Measurement characteristics

  • The Wiver provides comprehensive vibration and temperature monitoring capabilities. For vibration analysis, the sensor captures measurements across a wide dynamic range from ±2g to ±16g with sampling rates up to 26.67 kHz. This enables detailed spectral analysis up to 13.33 kHz, with resolution as fine as 0.01 Hz for precise component identification.
  • The device ensures measurement reliability through multiple technical features. Temperature stability is maintained with sensitivity variation under 0.025%/°C, while measurement accuracy is guaranteed by ±2% sensitivity error and   ±0.03% frequency accuracy. The tri-axial sensor provides a 6300 Hz bandwidth on all axes, with a low noise floor of 70 μg Hz-1/2 ensuring clean signal capture.
  • Analysis flexibility is achieved through configurable parameters. Users can select from multiple windowing options including Hann, Hamming, Flat-Top, Rectangular, and Blackman-Harris. Spectral resolution is adjustable up to 13,333 lines with customizable overlap from 0-100%. The reporting schedule can be tailored to application needs, with RMS values available every 2-15 minutes and spectral data every 2-6 hours.
  • Mounted on machine with standard base.
  • With 2x AA batteries, base (mounted on machine) not included.
  • Range is highly dependent on location and RF environment (eg. clearance to metallic objects, presence of walls/ceilings) and installation of the MAPER Gateway.

Temperature monitoring covers the full industrial range from -30°C to 100°C. Measurement accuracy is optimized for standard operating conditions (-10°C to 60°C) at ±3°C, with ±3.5°C accuracy maintained across the extended range. This ensures reliable temperature tracking across all operating conditions.

Radio Physical Layer Specifications

The Wiver sensor utilizes the IEEE 802.15.4-2015 O-QPSK PHY layer with Direct Sequence Spread Spectrum (DSSS) modulation. This configuration provides robust wireless communication in industrial environments:

  • The Offset Quadrature Phase-Shift Keying (O-QPSK) modulation, combined with DSSS, offers excellent interference resistance and efficient spectrum usage
  • 2MHz channel spacing allows for 5 non-overlapping channels in the 915-925 MHz band, centered at  916…924MHz
  • Channel bandwidth of 850kHz at -6dB provides sufficient data throughput while maintaining spectral efficiency
  • Maximum EIRP of 50mW enables reliable communication range while meeting regulatory requirements
  • Power spectral density below -6 dBm/3kHz ensures minimal interference with adjacent channels and other systems

This implementation enables reliable sensor data transmission even in challenging RF environments while maintaining power efficiency for extended battery life.

NFC Interface Specifications
The device incorporates a Dynamic NFC Tag Type 5 implementing ISO/IEC 15693 for device configuration and maintenance:

Specificazioni:

  • Dinamica Tag Type 5 with passive operation
  • ISO/IEC 15693 protocol support
  • Frequenza operativa: 13.56 MHz
  • Communication range: Up to 1.5 cm
  • Data transfer rate: Up to 53 Kbit/s

This interface enables simple device configuration using NFC-capable smartphones or tablets. The passive operation requires no battery power for configuration tasks.

Explosive atmosphere certification details

The WIVER-Ex sensors are certified for explosive atmospheres. They comply with following standards:

  • IEC60079-0: ed. 6.0 (2011-06)
  • IEC60079-11: ed. 6.0 (2011-06)
  • IEC60079-26: ed. 6.0 (2011-06)
  • Certificate issuer: Bureau Veritas
  • Certificate number: BVA 23.0002X (Certificate upon request, contact MAPER for more information)

The WIVER-Ex sensors are rated as follows:

  • Ex ia I Ma
  • Ex ia IIC T4 Ga
  • Ex ia IIIC T150°C Da  -20°C ≤ Ta ≤ 60°C

Marcatura
The WIVER-Ex sensors are marked as follows:

MAPER-Wiver-High-Performanc-Wireless-Condition-Monitoring-Sensor (1)The WIVER-Ex sensors may be installed in the following zones

Zona gruppu Classe di temperatura
Minieri I
0, 1, 2 IIA, IIB, IIC T4
20, 21, 22 IIIA, IIIB, IIIC T150 ° C

Température ambiante : -20°C à 60°C

  • Notes for gas applications
  • The WIVER-Ex may be installed in the following zones:
  • – Zone 0: explosive gas atmosphere is present continuously or for long periods or frequently.
  • – Zone 1: explosive gas atmosphere is likely to occur periodically or occasionally in normal operation.
  • – Zone 2: explosive gas atmosphere is not likely to occur in normal operation but, if it does occur, it will exist for a short period only.

for the following gas groups:

  • Gas group IIA: Atmospheres containing propane, or gases and vapors of equivalent hazard.
  • Gas group IIB: Includes group IIA gases plus atmospheres containing ethylene, or gases and vapors of equivalent hazard.
  • Gas group IIC: Includes group IIB gases plus atmospheres containing acetylene or hydrogen, or gases and vapors  of equivalent hazard.

having a temperature classification of:

  • T1: 450°C
  • T2: 300°C
  • T3: 200°C
  • T4: 135°C

Notes for dust applications

  • WIVER-Ex may be installed in the following zones:
  • Zone 20: explosive dust atmosphere is present continuously or for long periods or frequently.
  • Zone 21: explosive dust atmosphere is likely to occur periodically or occasionally in normal operation.
  • Zone 22: explosive dust atmosphere is not likely to occur in normal operation but, if it does occur, it will exist for  a short period only.  for the following dust groups:
  • Dust group IIIA: Atmospheres containing combustible flyings.
  • Dust group IIIB: Includes group IIIA dusts plus atmospheres containing non-conductive dust.
  • Dust group IIIC: Includes group IIIC dusts plus atmospheres containing conductive dust.
  • The maximum Surface Temperature for Dust Application is 150°C.

Installazione è mantenimentu

  • L'installazione deve esse realizata in cunfurmità cù l'ultime emissioni di i seguenti standard:
  • IEC 60079-14: Explosive atmospheres – Electrical installations design, selection and erection.
  • IEC 60079-10-1: Explosive atmospheres – Classification of areas. Explosive gas atmospheres.
  • IEC 60079-10-2: Explosive atmospheres – Classification of areas. Explosive dust atmospheres.
  • The installation, maintenance and operation of this equipment must be carried out by qualified personnel only.
  • U dispusitivu ùn deve esse mudificatu.
  • To avoid accumulation of electrostatic charge, clean only with a damp tela.
  • Only approved batteries must be used: Energizer model L91
  • A visual inspection is recommended every 6 months, to verify the integrity and the marking and integrity of the device.

STATU FCC

Stu dispusitivu hè conforme à a Parte 15 di e regule FCC. U funziunamentu hè sottumessu à i seguenti dui cundizioni:

  1. Stu dispusitivu ùn pò causari interferenza dannusu, è
  2.  Stu dispusitivu deve accettà ogni interferenza ricevuta, cumpresi l'interferenza chì pò causà operazione indesiderata.

Cambiamenti o mudificazioni à sta unità chì ùn sò micca appruvati espressamente da a parte rispunsevuli di u cumplimentu puderanu annullà l'autorità di l'utilizatore per operà l'equipaggiu.

NOTA: Stu equipamentu hè statu pruvatu è truvatu cum'è i limiti per un dispositivu digitale di Classe B, in cunfurmità cù a Parte 15 di e Regule FCC. Questi limiti sò pensati per furnisce una prutezzione raghjone contr'à l'interferenza dannosa in una stallazione residenziale. Stu equipamentu genera usi è pò irradià energia di freccia radio è, se ùn hè micca stallatu è utilizatu in cunfurmità cù l'istruzzioni, pò causà interferenza dannosa à e cumunicazioni radio. Tuttavia, ùn ci hè micca guarantisci chì l'interferenza ùn accade micca in una stallazione particulare. Se l'apparecchiatura provoca interferenza dannosa à a ricezione di a radio o di a televisione, chì pò esse determinata spegnendu è accendendu l'equipaggiu, l'utilizatore hè incuraghjitu à pruvà à corregge l'interferenza cù una o più di e seguenti misure:

  • Riorientate o rilocate l'antenna di ricezione.
  • Aumente a separazione trà l'equipaggiu è u ricevitore.
  • Cunnette l'equipaggiu in una presa in un circuitu diversu da quellu à quale hè cunnessu u ricevitore.
  • Cunsultate u rivenditore o un tecnicu espertu di radio/TV per aiutu.

Stu dispositivu è a so antenna (e) ùn deve micca esse situatu o funziunamentu in cunghjunzione cù qualsiasi altra antenna o trasmettitore.

Dichjarazione di l'esposizione à a radiazione

U dispusitivu hè statu valutatu per risponde à i requisiti generali di esposizione RF in cundizione di esposizione portatile senza restrizioni.

Cuntattu

Domande Frequenti

What battery type should I use for the WIVER sensor?

We recommend using 2x AA alkaline batteries, specifically Energizer E91 Max or Duracell MN1500, or 2x Energizer L91 (AA Lithium) for best performance.

What is the operating temperature range of the WIVER sensor?

The WIVER sensor can operate in temperatures ranging from -30°C to 100°C.