GOCHIFIX F32021204606

Manuale d'usu di l'oscilloscopiu, multimetru è generatore di forme d'onda GOCHIFIX 3-in-1

Modelu: F32021204606

1. Introduzione

The GOCHIFIX F32021204606 is a versatile 3-in-1 handheld device integrating a portable oscilloscope, a digital multimeter, and a waveform generator. Designed for a wide range of applications including car repair, appliance repair, electronic repair, and educational research, this instrument offers high-speed sampling, accurate measurements, and convenient data storage in a compact and portable design.

2. Caratteristiche di u produttu

  • Funzionalità 3-in-1: Combines a 12MHz analog bandwidth oscilloscope, a 6000-count digital multimeter, and a signal source.
  • One-Key Switching: Quickly switch between modes (Oscilloscope, Multimeter, Signal Generator) by pressing the 'AUTO' button for 2 seconds.
  • High-Speed Oscilloscope: Features a 50Msps sampling rate for accurate signal analysis within a 12MHz bandwidth. Waveform amplitude up to 200V/div, max measurement 1600Vpp.
  • Generatore di forme d'onda: Capable of outputting Sine, Triangle, and Square waveforms for debugging and signal analysis.
  • 6000-Count Multimeter: Provides higher resolution for more accurate measurement results compared to 4000-count devices.
  • Cuncepimentu di risparmiu energeticu: Equipped with a replaceable 18650 lithium battery and Type-C charging interface. Features automatic sleep after 15 minutes of inactivity for extended battery life (over 8 hours continuous use).
  • Enhanced Knob Dial: Direct switching to oscilloscope mode for AC and DC voltage measurements by rotating the knob.
  • Storage di dati: Stores up to 100 sets of data and 10 waveforms, with real-time and stored data displayed on the same screen.
  • Disegnu Portable: Compact dimensions (6.3 x 3.3 x 1.3 inches) and lightweight (0.44 lbs) for easy portability.

3. Cuntenutu di u pacchettu

Verificate attentamente u pacchettu à a ricezione per assicurà chì tutti l'articuli sianu presenti è senza danni:

  • 1 x GOCHIFIX 3-in-1 Oscilloscope Multimeter Waveform Generator
  • 1 x Coppia di cavi di prova
  • 1 x Cavo di ricarica Type-C
  • 1 x Manuale d'utilizatore
  • 1 x Borsa Portable
  • 1 x Scatola di imballaggio
Product Accessories: Oscilloscope, Test Leads, Type-C Cable, User Manual, Portable Bag, Packing Box
Figure 3.1: Included Product Accessories

4. Specificazioni

ParametruValore
MarcaGOCHIFIX
MudelluF32021204606
Dimensioni di u produttu6.3 x 3.3 x 1.3 inch (160 x 84 x 33 mm)
Pesu0.44 lbs (7.04 ounces / 200g)
Size Display2.4 inches Color Screen
Larghezza di banda di l'oscilloscopiu12 MHz (Analog)
Sampling Rate50 Msps
Canali digitale2
Conteggi di multimetri6000 cunti
Output generatore di forma d'ondaSine Wave (100Hz-100KHz), Triangle Wave (100Hz-50KHz), Square Wave (100Hz-20KHz)
Tipu di batterie18650 Lithium Ion (Replaceable, Included)
Interfaccia di caricaTipu-C
Storage di dati100 sets of data, 10 waveforms
CertificazioneCE
Mini & Portable design with dimensions 6.3 inches height, 3.3 inches width, 1.3 inches depth, and 0.44 lbs weight.
Figura 4.1: Dimensioni è purtabilità di u dispusitivu

5. Dispositivu Finituview è cuntrolli

Familiarize yourself with the device's layout and controls before operation.

Product Parameters and Controls: 2.4 inch Color Screen Display, Multi-Function Keys (F1-F4), Backlight and Signal Source Settings, Data Locking and Storage, Frequency/Duty Cycle, AC/DC Micro-amp, AC/DC mA, AC/DC 10A, Switches and Charging, Capacitor, Resistance/Diode/On-Off Test, DC/AC Voltage, DC/AC Millivolt Voltage, Multimeter Status, Oscilloscope Status, Signal Source Status.
Figura 5.1: Pannellu frontale sopraview è Funzioni chjave
Detailed German instruction diagram for Oscilloscope Multimeter controls, Signal Source operation, Multimeter operations, Data Storage, and Fuse Replacement.
Figure 5.2: Control Diagram and Key Operations

Funzioni chjave:

  • Pulsante AUTO: Short press for automatic waveform capture in oscilloscope mode. Press and hold for 2 seconds to switch between Oscilloscope, Multimeter, and Signal Generator modes.
  • Buttoni F1-F4: Multi-function keys whose specific function depends on the active mode (e.g., adjusting time base, voltage amplitude, trigger settings, waveform type, frequency, duty cycle, output voltagè).
  • Buttone di l'icona di a lampadina: Controls backlight and signal source settings.
  • Pulsante SAVE: Short press to save current data or waveform. Press and hold for 2 seconds to enter data retrieval mode.
  • Manopola rotativa: Selects measurement functions (OFF, V~, mV, Ω, Cx, Hz/%, mA, µA, 10A, OSC VDCX).
  • Terminali di input: MAX 10A FUSE, MAX 600mA FUSE, COM, CAT II 1000V.

6. Setup

6.1. Installazione è carica di a batteria

  1. The device comes with a replaceable 18650 Lithium Ion battery. Ensure it is correctly installed according to the polarity markings.
  2. To charge the device, connect the provided Type-C cable to the charging port on the side of the device and to a suitable USB power adapter (not included).
  3. The charging port is protected by a rubber cover. Ensure it is properly sealed when not charging to prevent dust and moisture ingress.
Built-in 1500mAh rechargeable battery with Type-C charging port.
Figura 6.1: Porta di carica di tipu C

6.2. Cunnessione di i cavi di prova

  1. For most measurements, connect the black test lead to the 'COM' (common) input jack.
  2. Connect the red test lead to the appropriate input jack based on the desired measurement:
    • Per voltage (V~, mV), resistance (Ω), capacitance (Cx), frequency (Hz/%), diode, and continuity tests, connect to the 'CAT II 1000V' jack.
    • For current measurements up to 600mA (mA, µA), connect to the 'MAX 600mA FUSE' jack.
    • For current measurements up to 10A (10A), connect to the 'MAX 10A FUSE' jack.
  3. Always ensure test leads are securely connected before taking measurements.

7. Operating Instructions

7.1. Accensione/Spegnimentu è Cambiamentu di Modu

  1. To power on the device, rotate the knob from 'OFF' to any measurement function.
  2. To switch between Oscilloscope, Multimeter, and Signal Generator modes, press and hold the 'AUTO' button for 2 seconds. The display will indicate the active mode.
  3. To power off, rotate the knob to the 'OFF' position. The device also has an automatic sleep function after 15 minutes of no operation.

7.2. Oscilloscope Mode Operation

In Oscilloscope mode, the device displays real-time waveforms, allowing for visual analysis of electrical signals.

  1. Entrata in u modu Oscilloscopiu: Rotate the knob to 'OSC VDCX' or press and hold 'AUTO' for 2 seconds until 'Oscilloscope Status' is displayed.
  2. Cattura automatica: Short press the 'AUTO' button to automatically adjust the time base and voltage amplitude for a stable waveform display.
  3. Regolazioni manuali:
    • Use F1 (TIME) to adjust the time base (horizontal scale).
    • Use F2 (VOLT) to adjust the voltage amplitude (vertical scale).
    • Use F3 (TRIG) to access trigger settings for stable waveform capture.
  4. Forma d'onda Amplattitudine: The device supports waveform amplitudes up to 200V/div, with a maximum measurement of 1600Vpp.
3-in-1 Handheld Oscilloscope overview, showing modes (Oscilloscope, Multimeter, Signal Generator) and one-button switch mode.
Figure 7.1: Oscilloscope Mode Display

7.3. Multimeter Mode Operation

A funzione multimetru permette una misurazione precisa di diversi parametri elettrici.

  1. Entrata in u modu Multimetru: Rotate the knob to the desired measurement function (V~, mV, Ω, Cx, Hz/%, mA, µA, 10A) or press and hold 'AUTO' for 2 seconds until 'Multimeter Status' is displayed.
  2. Selezzione di funzione: Rotate the knob to select the specific measurement function (e.g., DC/AC Voltage, Resistance, Capacitance, Current).
  3. Selezzione di gamma: Press F1 and F2 simultaneously to switch between manual and automatic ranging.
  4. Impurtante: Always ensure correct input and output polarities when connecting test leads to the circuit under test to obtain accurate measurement results and prevent damage to the device or circuit.
Multifunctional Test capabilities including DC/AC Voltage, Current, Resistance, Capacitance, Frequency, Duty Cycle, Diode, and Continuity.
Figure 7.2: Multimeter Measurement Functions

7.4. Waveform Generator Mode Operation

The waveform generator can output various signals for testing and debugging.

  1. Entering Waveform Generator Mode: Press and hold 'AUTO' for 2 seconds until 'Signal Source Status' is displayed.
  2. Selezzione di a forma d'onda: Use F1 (WAVE) to select the desired waveform type: Sine, Triangle, or Square.
  3. Ajustamentu di frequenza: Use F2 (FREQ) to adjust the output frequency.
  4. Duty Cycle Adjustment: Use F3 (DUTY) to adjust the duty cycle (for square and triangle waves).
  5. Uscita Voltage Ajuste: Use F4 (VOLT) to adjust the output voltage amplatitudine.
  6. Output On/Off: Use the light bulb icon button to toggle the signal source output ON or OFF.
Waveform Generator output display showing wave type, frequency, duty cycle, voltage, and output status.
Figure 7.3: Waveform Generator Interface

7.5. Data Storage and Retrieval

The device allows you to save and review measurement data and waveforms.

  1. Salvà dati: Press the 'SAVE' button to store the current measurement data or waveform. The device can store up to 100 sets of data and 10 waveforms.
  2. Retrieving Data: Press and hold the 'SAVE' button for 2 seconds to enter data retrieval mode. Use the F1-F4 buttons to navigate through the stored data and waveforms.
Data Storage feature, showing saving 100 sets of data and 10 waveforms by pressing the SAVE button.
Figure 7.4: Data Storage Functionality

8. Mantenimentu

8.1. Pulizia

Per mantene e prestazioni è l'aspettu di u dispusitivu:

  • Asciugà u dispusitivu cù un soft, damp tela. Ùn aduprate micca detergenti abrasivi o solventi.
  • Ensure no liquids enter the device, especially through the input jacks or charging port.

8.2. Cura di batterie

  • The device uses a replaceable 18650 Lithium Ion battery. If the battery needs replacement, ensure you use a battery of the same type and specifications.
  • Charge the battery regularly, even if the device is not in use, to prolong its lifespan.
  • Avoid exposing the device or battery to extreme temperatures.

8.3. Sostituzione di fusible

WARNING: Risk of electric shock. Ensure the device is powered off and disconnected from any power source or circuit before attempting to replace fuses.

  1. If a fuse blows, the corresponding current measurement function will cease to work.
  2. To replace a fuse, carefully open the battery compartment or the designated fuse access panel (refer to the device's physical markings if available).
  3. Replace the blown fuse with a new one of the correct type and rating:
    • For the mA/µA range: 600mA/250V fuse.
    • For the 10A range: 10A/250V fuse.
  4. Close the compartment or panel securely after replacement.

8.4. Storage

  • When not in use for extended periods, store the device in its portable bag in a cool, dry place, away from direct sunlight and extreme temperatures.
  • Assicuratevi chì u dispusitivu sia spento prima di almacenallu.

9. Risoluzione di prublemi

If you encounter issues with your GOCHIFIX 3-in-1 device, consider the following basic troubleshooting steps:

  • U dispositivu ùn si accende micca: Check if the battery is charged. Ensure the battery is correctly installed.
  • Letture imprecise: Verify that the test leads are correctly connected to the appropriate input jacks and the rotary knob is set to the correct function. Ensure the circuit under test is properly connected.
  • Nisuna misurazione di corrente: Check if the corresponding fuse (600mA or 10A) has blown and replace it if necessary (refer to Section 8.3).
  • Unstable oscilloscope waveform: Try using the 'AUTO' button for automatic adjustment. Adjust the time base (F1) and voltage amplitude (F2) manually. Check trigger settings (F3).
  • Signal Generator not outputting: Ensure the signal source output is turned ON (light bulb icon button). Check waveform, frequency, duty cycle, and voltage paràmetri.

Se i prublemi persistenu, cuntattate l'assistenza clienti per più assistenza.

10. Cunsiglii d'utilizatori

  • Always double-check your connections and settings before taking any measurements, especially when dealing with live circuits.
  • Utilize the automatic sleep function to conserve battery life during periods of inactivity.
  • Pigliate avanzutage of the data storage feature to record and review important measurements or waveforms for later analysis.
  • Keep the device and its accessories clean and stored in the provided portable bag to protect them from damage.

11. Garanzia è Support

This GOCHIFIX product is designed for reliability and performance. For any questions, technical assistance, or support inquiries, please refer to the contact information provided by your retailer or the official GOCHIFIX support channels. Please retain your proof of purchase for warranty claims.

Documenti cunnessi - F32021204606

Preview GOCHIFIX LG0112 Livellu Laser Manuale d'uso
Manuale d'usu cumpletu per u livellu laser GOCHIFIX LG0112. Include note di sicurezza, dettagli di u pruduttuview, istruzioni operative per l'autolivellamentu, i modi manuali è à impulsi, dettagli di l'accessori, specifiche è informazioni di garanzia.