1. Introduzione

The LAUNCH CNC605A Injector Cleaner & Tester is an advanced electromechanical product designed for cleaning and testing fuel injectors. Utilizing ultrasonic cleaning technology and precise fuel pressure control, this equipment simulates engine working conditions to effectively clean and test GDI, EFI, and SFI injectors. It also supports on-vehicle cleaning of injectors and the fuel supply system.

LAUNCH CNC605A Injector Cleaner and Tester main unit
Figure 1: LAUNCH CNC605A Injector Cleaner & Tester Main Unit

2. Funzioni chjave

  • Pulizia à ultrasoni putente: Offers complete cleaning to injectors/pump, removing carbon deposits.
  • Stable Testing Pressure: Microcomputer-controlled stable testing pressure with a large adjustable range.
  • Funzionamentu automaticu: Supports automatic cleaning, testing injectors, and real-time monitoring of dynamic values via microcomputer control and LCD display.
  • Automatic Fuel Draining: Features automatic fuel draining through preset programs for specific test items.
  • Disegnu umanizatu: System pressure can be quickly restored to default values.
  • Interfaccia d'utilizatore: LCD display for operation details and touch button controls.
Diagram showing LAUNCH CNC605A features including ultrasonic cleaning, sealing test, fuel injection quantity test, uniformity and sprayability test, no disassembly needed, and automatic mode.
Figura 2: Overview of CNC605A Features and Capabilities

3. Specificazioni

3.1. Cundizioni di travagliu

  • Temperature : -10 ℃ à + 40 ℃
  • Umidità Relativa: <85%
  • Intensity of Outer Magnetic Field: <400Am
  • Sicurezza: No naked flame within 2m of the equipment.

3.2. Specifiche tecniche

ParametruValore
Nome di marcaLAUNCH
Nome di mudelluCNC605A
Tipu d'articuluAnalizzatore di u mutore
Alimentazione di l'unità principaleAC220V ~ 50/60Hz
Putenza di u pulitore à ultrasoni60 W
Pressione di Carburante0.1-10 bar
Ingressu d'aria5-8 bar
Gamma RPM100-9900 rpm (Step: 100 rpm)
PW Range0.5-25.0 ms (Step: 0.1 ms)
Gamma di timer1-30 min
Capacità di u tank~ 3L
Pesu di l'articulu20 kg
Altezza di l'articulu41.5 inch
Larghezza di l'articulu21.5 inch
Lunghezza di l'articulu58.4 inch
Certificazione di Test EsterniCE
MaterialePLACTIS
Versione SoftwareU PIÙ NOVU
Versione di hardwareU PIÙ NOVU
Batterie incluse?Innò
Actualizazione di u SoftwareInnò
Image showing various accessories and adapters included with the CNC605A injector cleaner and tester.
Figure 3: Included Accessories and Adapters

4. Setup

Before operating the LAUNCH CNC605A, ensure the following setup steps are completed:

  1. Unpacking: Carefully remove the main unit and all accessories from the packaging. Inspect for any damage.
  2. Placement: Place the unit on a stable, level surface in a well-ventilated area, away from any naked flames or sources of ignition.
  3. Cunnessione di putenza: Connect the main unit to an AC220V~50/60Hz power supply. Ensure the voltage currisponde à i requisiti di l'unità.
  4. Cunnessione di furnimentu d'aria: Connect an air supply providing 5-8 bar pressure to the designated air inlet port.
  5. Injector Preparation: Before placing injectors into the ultrasonic bathtub, clean their exterior thoroughly with a suitable cleaning liquid to remove dirt.
Close-up of the CNC605A control panel and injector setup, showing injectors mounted for testing.
Figure 4: Injector Setup on the Main Unit

5. Operazione

The CNC605A offers various functions for comprehensive injector cleaning and testing. Follow these general steps for operation:

5.1. General Operating Procedure

  1. Pulizia iniziale: After external cleaning, place the injectors into the ultrasonic bathtub. Ensure the cleaning fluid does not exceed the connection port of the pulse line.
  2. Pulizia ultrasonica: Activate the ultrasonic system. This process dislodges carbon build-up and other particles from inside the injectors.
  3. Mounting Injectors: Fix the cleaned injectors onto the main machine's test bench.
  4. Test Liquid Addition: Add the appropriate test liquid to the glass tubes, ensuring it reaches at least half the tube's height.
  5. Performing Tests: Select and perform the desired tests from the available functions.
  6. Retesting: After cleaning cycles, return the injectors to the flow bench for retesting of all functions to verify performance improvement.

5.2. Specific Test Functions

  • Pulizia ultrasonica: Removes carbon deposition from injectors.
  • Uniformity / Sprayability Test: Checks the uniformity of injection amount and monitors spray patterns using backlight.
  • Test di fuga: Evaluates injector sealing and dribbling conditions under system pressure.
  • Injecting Volume Test: Measures the injecting amount over 15 seconds of constant injection.
  • Auto. Test: Runs a preset program of tests for injectors.
  • On-vehicle Cleaning: Performs cleaning to remove carbon deposition directly on the vehicle.
  • Paràmetru: Allows configuration of system parameters, including language.
  • Richiede: Provides access to equipment usage information.
  • infurmazione: Displays hardware and software version details.

6. Mantenimentu

Proper maintenance ensures the longevity and optimal performance of your CNC605A Injector Cleaner & Tester.

  • Pulizia regulare: Keep the exterior of the machine clean. Wipe down surfaces with a soft, damp tela.
  • Cleaning Fluid Management: After ultrasonic cleaning, the remaining cleaning fluid can be recycled for future use. Dispose of spent fluids according to local regulations.
  • Test Liquid Management: Regularly check the level and condition of the test liquid. Replace or replenish as needed.
  • Injector Cleaning: Always clean the outside of injectors before placing them in the ultrasonic bathtub to prevent contamination of the cleaning fluid.
  • Conservazione: When not in use, store the unit in a clean, dry environment within the specified temperature range.

7. Risoluzione di prublemi

This section addresses common issues you might encounter with your CNC605A unit.

Issue: Unit does not power on.
  • Ensure the power cable is securely connected to both the unit and a functional AC220V~50/60Hz power outlet.
  • Verify that the power switch on the unit is in the "ON" position.
  • Check the power source for proper voltage and functionality.
Issue: Ultrasonic cleaning is ineffective.
  • Ensure the ultrasonic bathtub is filled with the correct cleaning liquid to the appropriate level.
  • Verify that the injectors were externally cleaned before being placed in the bathtub.
  • Check the ultrasonic power setting.
Issue: Inaccurate test results.
  • Ensure the test liquid is clean and at the correct level in the glass tubes.
  • Verify that the air inlet pressure is within the specified range (5-8 bar).
  • Check for proper sealing of injectors on the test bench to prevent leaks during testing.
  • Recalibrate the unit if necessary (refer to advanced settings or contact support).
Issue: Display language needs to be changed.
  • Navigate to the "Setting" menu on the LCD display to adjust the system language.

8. Cunsiglii d'utilizatori

  • Voltage Compatibilità: The unit operates on AC220V. If your region uses 110V, a suitable voltage converter will be required to ensure proper operation and prevent damage.
  • Impostazioni di lingua: The display language can be changed via the 'Setting' menu. Check for available language options to suit your preference.

9. Garanzia è Support

The LAUNCH CNC605A Injector Cleaner & Tester comes with a commitment to quality and customer support.

  • Assistenza tecnica per a vita: LAUNCH provides lifetime technical support for this product.
  • Sostituzione gratuita: The product may be eligible for free replacement for 365 days from the date of purchase. Please refer to your purchase agreement for specific terms and conditions.
  • For any technical assistance, troubleshooting beyond this manual, or warranty claims, please contact your authorized LAUNCH dealer or customer service.

Documenti cunnessi - CNC605A

Preview Manuale d'usu di u tester di batteria Bluetooth LAUNCH BST360
Manuale d'usu per u tester di batteria Bluetooth LAUNCH BST360, chì detalla e so caratteristiche per a salute di a batteria, u sistema di carica è l'avviu di i testi di u sistema, inseme cù l'infurmazioni di cunnessione è di garanzia.
Preview Manuale di a scatula di batterie LAUNCH X-431 GDS: Guida di test di batterie automobilistiche
Manuale d'usu cumpletu per a LAUNCH X-431 GDS Batterybox, chì detalla e procedure di prova di e batterie automobilistiche, e precauzioni operative è e specifiche tecniche per usu prufessiunale.
Preview Manuale d'usu di LAUNCH Creader Professional CRP123
Stu manuale d'usu furnisce struzzioni cumplete per u strumentu di diagnostica automobilistica LAUNCH Creader Professional CRP123, chì copre e so caratteristiche, u funziunamentu, e procedure di diagnostica, l'impostazioni, l'aghjurnamenti è a risoluzione di i prublemi.
Preview Guida di avviamentu rapidu di LAUNCH Creader Professional 123X
Una guida rapida per u LAUNCH Creader Professional 123X, chì detalla a cunfigurazione iniziale, a carica è e procedure diagnostiche di basa.
Preview Manuale d'usu di u strumentu di diagnostica LAUNCH: Funziunalità, Funziunamentu è Manutenzione
Stu manuale d'usu cumpletu per u strumentu di diagnostica LAUNCH (FCC ID: XUJWO0805A) guida l'utilizatori à traversu e so numerose funzioni, cumprese a diagnosi intelligente è lucale di u veiculu, una vasta gamma di funzioni di serviziu cum'è reset è calibrazioni, diagnostica remota, aghjurnamenti di software è supportu per diversi moduli cum'è ADAS è TPMS. Fornisce informazioni essenziali nantu à a cunfigurazione, u funziunamentu è a sicurezza per i prufessiunali di l'automobile è l'utilizatori avanzati di bricolage.
Preview Audi 5th Generation Engine Replacement: Operating Instructions and Anti-Theft Data Synchronization
This document provides detailed operating instructions for replacing an Audi 5th generation engine. It covers the process of reading, loading, and synchronizing anti-theft data using LAUNCH diagnostic tools like PADIII, PAD V, and X431 G3, ensuring proper ECU replacement and coding.