Enersys 0809-0012

Enersys (Hawker) Cyclon 0809-0012 X-Cell 6 Volt/5 Amp Hour Sealed Lead Acid Battery User Manual

Model: 0809-0012 | Brand: Enersys

1. Introduzione

This manual provides essential information for the safe and effective use of your Enersys (Hawker) Cyclon 0809-0012 X-Cell 6 Volt/5 Amp Hour Sealed Lead Acid Battery. This 6-volt, 5 Ah pure lead sealed lead-acid battery is designed for general applications such as emergency lighting, UPS systems, and various electronic equipment. Please read this manual thoroughly before installation and operation.

Enersys Cyclon 0809-0012 X-Cell 6V 5Ah Sealed Lead Acid Battery

Figure 1: Enersys Cyclon 0809-0012 X-Cell 6V 5Ah Sealed Lead Acid Battery, front view.

2. Caratteristiche di u produttu

The Enersys Cyclon 0809-0012 battery offers several key advantages:

3. Cunfigurazione è installazione

Follow these guidelines for proper setup and installation:

  1. Ispezione: Prima di l'installazione, verificate visivamente a batteria per eventuali segni di danni.
  2. Orientazione: The battery can be installed in any orientation except inverted (terminals facing downwards).
  3. Cunnessioni: Ensure all connections are clean, tight, and correctly polarized. Connect the positive (+) terminal of the battery to the positive terminal of the load/charger, and the negative (-) terminal to the negative terminal. Incorrect polarity can damage the battery and connected equipment.
  4. Ventilazione: While minimal gassing occurs, ensure adequate ventilation in the installation area.
  5. Cundizioni Ambientali: Install the battery in a cool, dry place, away from direct sunlight, heat sources, and flammable materials.
Close-up of battery positive terminal

Figura 2: Primu pianu view of a battery terminal, showing the connection point.

Close-up of battery negative terminal

Figure 3: Another close-up view of a battery terminal, illustrating the robust design.

4. Operazione

This sealed lead-acid battery is designed for reliable power delivery. For optimal performance and longevity, adhere to the following operational guidelines:

5. Mantenimentu

The Enersys Cyclon battery is a low-maintenance unit. However, proper care ensures maximum service life:

Battery recycling symbol and nonspillable label

Figure 4: Label indicating the battery is nonspillable and must be recycled.

6. Risoluzione di prublemi

Sè avete prublemi cù a vostra batteria, cunsiderate i seguenti passi cumuni di risoluzione di i prublemi:

For persistent issues, consult a qualified technician or contact Enersys customer support.

7. Specificazioni

Key technical specifications for the Enersys Cyclon 0809-0012 battery:

SpecificazioneValore
Numero di mudellu0809-0012
MarcaEnersys
Voltage6.00 Volts
Capacità batterie5 Amp Ore
A cumpusizioni di a batteriaAcid di piombu sigillatu
Dimensioni di u produttu5.48 x 2.12 x 3.02 inch
Pesu di l'articulu2.16 liri
UPC740737205131
ASINB0002ILK7W
Top view of Enersys Cyclon battery with label showing model number and specifications

Figura 5: Top view of the battery, displaying the product label with model number and key specifications.

8. Informazioni di sicurezza

Per piacè osservate e seguenti precauzioni di sicurezza:

9. Garanzia è Supportu

For specific warranty details and customer support, please refer to the documentation provided at the time of purchase or contact Enersys directly through their official website or customer service channels. Ensure you have your model number (0809-0012) and purchase information available when seeking support.

Documenti cunnessi - 0809-0012

Preview Specifiche tecniche di a batteria militare EnerSys ArmaSafe Plus 12FV120
Scheda tecnica per a batteria di qualità militare EnerSys ArmaSafe Plus 12FV120, cù una capacità di 126 Ah, 1225A CCA è una larga gamma di temperature di funziunamentu. Include specifiche, caratteristiche, vantaghji è informazioni di cunfurmità.
Preview HAWKER Perfect Plus Baterie: Uživatelská Příručka pro Trakční Baterie PzS/PzB
Komplexní uživatelská příručka pro trakční baterie HAWKER Perfect Plus™ typu PzS/PzB. Obsahuje informace o bezpečnosti, provozu, nabíjení, údržbě, skladování a volitelném příslušenství pro průmyslová vozidla.
Preview Ironclad Flooded Lead-Acid Batteries Owner's Manual
Comprehensive owner's manual for EnerSys Ironclad Flooded Lead-Acid Batteries, covering safe handling, installation, operation, maintenance, and troubleshooting.
Preview Manuale d'usu di e batterie certificate EnerSys Perfect Plus è Water Less ATEX UKEX
This user manual provides comprehensive information on the safe handling, operation, maintenance, and installation of EnerSys Perfect Plus and Water Less ATEX UKEX certified batteries. It covers technical specifications, safety precautions, charging, discharging, and optional accessories like the Aquamatic water filling system and electrolyte circulation system.
Preview PowerSafe® SBS® EON® Installation, Operation and Maintenance Manual
Comprehensive guide for the installation, operation, and maintenance of EnerSys PowerSafe SBS EON batteries, featuring TPPL technology for enhanced performance and longevity.
Preview Caricatore di batteria modulare Hawker Lifetech® - Istruzioni per l'usu
Istruzzioni cumplete per l'usu di i caricabatterie modulari Hawker Lifetech®, chì coprenu a sicurezza, l'usu cunsigliatu, i cunnessione elettriche, u funziunamentu è i codici di guastu. Cuncepitu per batterie industriali à piombu-acidu, AGM è à gel.