Dickson TM320

Dickson TM320 Temperature and Humidity Data Logger

Manuale d'istruzzioni

1. Introduzione

The Dickson TM320 is a versatile data logger designed to accurately monitor and record temperature and humidity levels. Featuring a large display for real-time readings, audio/visual alarms, and convenient data transfer options via USB and flash card, it provides essential environmental monitoring for various applications. Its user-friendly design ensures ease of use and reliable performance.

  • USB Enabled Download: Easily transfer recorded data to a computer.
  • Flash Memory Data Transfer Capability: Utilize flash cards for convenient data retrieval.
  • Jumbo Display: Clear and easy-to-read real-time measurements.
  • Facile à aduprà: Intuitive interface for straightforward operation.

2. Informazioni di sicurezza

Please read all safety instructions before operating the device. Failure to do so may result in damage to the device or personal injury.

  • Do not expose the device to extreme temperatures outside its specified operating range.
  • Avoid direct contact with water or high humidity environments beyond the non-condensing range.
  • Aduprate solu e fonti d'alimentazione è l'accessori specificati.
  • Ùn pruvate micca à apre o riparà l'apparechju da per voi. Affidate tutta a manutenzione à persunale qualificatu.
  • Mantene fora di a portata di i zitelli.

3. Cuntenutu di u pacchettu

Verificate chì tutti l'articuli sò presenti in u pacchettu:

  • Dickson TM320 Data Logger
  • Manuale d'istruzzioni (stu documentu)
  • USB Cable (may be sold separately)
  • SD Card (may be sold separately)
  • Batteries (may be pre-installed or included)

4. Produttu Finituview

Fronte view of Dickson TM320 Data Logger with display showing '0.0' and battery indicator.

Figura 4.1: Fronte View. Shows the large digital display, 'DICKSON' branding, and three control buttons: MIN/MAX, ALARM, and SAVE.

Latu view of Dickson TM320 Data Logger showing USB port, sensor input, and ventilation slots.

Figura 4.2: Side View cù i Porti. Illustrates the mini-USB port for data transfer and external sensor input jacks, along with ventilation for internal sensors.

Torna view of Dickson TM320 Data Logger showing battery compartment and mounting holes.

Figura 4.3: Torna View. Displays the battery compartment cover and keyhole slots for wall mounting.

Top view of Dickson TM320 Data Logger showing the SD card slot.

Figura 4.4: Top View. Shows the slot for inserting an SD card for data storage and transfer.

5. Setup

5.1. Installazione di batterie

  1. Truvate u compartimentu di a batteria nant'à u spinu di u dispusitivu (vede a Figura 4.3).
  2. Trascinate u coperchio di a bateria aperta.
  3. Insert the required batteries (typically AA or AAA, check compartment for type) ensuring correct polarity (+/-).
  4. Chiudete a tappa di a bateria in modu sicuru.

5.2. Accensione iniziale

The device should power on automatically once batteries are installed. The display will illuminate, showing current readings or a startup sequence.

5.3. Muntà u dispusitivu

The TM320 can be placed on a flat surface or mounted on a wall:

  • Situazione di a superficia: Ensure the device is placed on a stable, level surface away from direct heat sources or extreme drafts.
  • Montatura à u muru: Use appropriate screws (not included) with the keyhole slots on the back of the device (refer to Figure 4.3) to secure it to a wall. Ensure it is mounted in a location representative of the environment you wish to monitor.

6. Operazione

6.1. Capisce u Display

The jumbo display provides real-time information:

  • Lettura attuale: Shows the live temperature or humidity value.
  • Unità: Indicates Fahrenheit (F) or Celsius (C) for temperature, and %RH for humidity.
  • Indicatore di batteria: Mostra a durata di a bateria restante.
  • CH (Canale): Indicates which channel is currently displayed (e.g., CH 1 for temperature, CH 2 for humidity).

6.2. Funzioni di u buttone

  • Buttone MIN/MAX: Press to cycle through minimum, maximum, and current readings for both temperature and humidity. Hold to reset min/max values.
  • Pulsante ALARM: Press to view current alarm settings. Hold to enter alarm setting mode (refer to section 6.4).
  • Pulsante SAVE: Press to manually save a data point.

6.3. Logging di dati

The TM320 automatically logs data at a pre-set interval. Data can be viewed on the display or downloaded to a computer.

6.4. Piazzà Alarmi

The device features audio/visual alarms for out-of-range conditions.

  1. Appughjà è tene premutu ALLARME button until the alarm setting mode is activated.
  2. Aduprà u MIN / MAX button to navigate between temperature and humidity alarm settings (high/low).
  3. Aduprà u SAVE button to adjust the alarm threshold values.
  4. Press ALLARME torna per cunfirmà è sorte da a modalità di impostazione.

6.5. Scaricamentu di dati (USB)

  1. Connect the TM320 to your computer using a compatible USB cable (refer to Figure 4.2 for port location).
  2. The device should be recognized as a removable storage device or require specific Dickson software (refer to manufacturer's website for software).
  3. Follow the software instructions to download and analyze the logged data.

6.6. Data Transfer (Flash Card)

If your model supports flash card data recovery:

  1. Insert a compatible SD card into the SD card slot (refer to Figure 4.4).
  2. The device may automatically transfer data or require a specific button press (consult software/manual for details).
  3. Remove the SD card and insert it into a computer's card reader to access the data.

7. Mantenimentu

7.1. Pulizia

Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure no liquid enters the sensor vents or ports.

7.2. Sustituzione di batterie

Replace batteries when the low battery indicator appears on the display. Follow the battery installation steps in Section 5.1.

7.3. Storage

When not in use for extended periods, remove the batteries and store the device in a cool, dry place, away from direct sunlight and extreme temperatures.

8. Risoluzione di prublemi

PrublemuCausa PossibileSoluzione
U dispusitivu ùn accende micca.Batterie morte o installate in modu incorrectu.Verificate a polarità di a batteria; rimpiazzatela cù batterie nove.
No data is being logged.Device not powered on; memory full; logging paused.Ensure device is on; download data to clear memory; check software settings for logging status.
Display shows 'Err' or abnormal readings.Sensor malfunction; out of range conditions.Move device to a stable environment; contact support if error persists.
Cannot download data via USB.Incorrect cable; driver issue; software not installed.Ensure correct USB cable; install necessary drivers/software from Dickson websitu.
L'alarma ùn sona micca.Alarm disabled; volume too low; thresholds set incorrectly.Check alarm settings (Section 6.4); ensure alarm is enabled and thresholds are appropriate.

9. Specificazioni

FeatureDetail
Numero di mudelluTM320
Gamma di temperatura-4 à 158 °F (-20 à 70 °C)
Intervallu di Umidità0-95% RH (senza condensazione)
U fabricatoreDickson Unigage Inc.
Dimensioni di u produttu19.56 x 16.51 x 8.89 cm (7.7 x 6.5 x 3.5 inch)
Pesu di u produttu385.55 g (0.85 lbs)
Trasferimentu di datiUSB, Flash Card (SD)
MostraLCD Jumbo

10. Garanzia è Support

This product is covered by a manufacturer's warranty. For specific warranty terms and conditions, please refer to the documentation included with your purchase or visit the official Dickson website. For technical support, troubleshooting assistance, or to inquire about replacement parts, please contact Dickson customer service through their official channels.

Dickson Official Websitu: www.dicksonlogger.com

Documenti cunnessi - TM320

Preview Guida di avvio rapidu di u registratore di dati à schermu tattile Dickson TSB/TWE/TWP
Una guida rapida per u registratore di dati touchscreen Dickson TSB/TWE/TWP, chì copre a cunfigurazione, a cunnessione via Ethernet o Wi-Fi, è l'integrazione cù a piattaforma DicksonOne.
Preview Registratore di prucessu DICKSON HT350: Guida di l'utente è cunfigurazione
Guida cumpleta per a cunfigurazione, l'usu è a risoluzione di i prublemi di u DICKSON Process Logger HT350, cumprese l'installazione di u software, a registrazione di dati è l'infurmazioni di garanzia.
Preview Dickson SP125, SP175, TP125 Environmental Data Logger Manual
Comprehensive user manual for Dickson SP125, SP175, and TP125 environmental data loggers. Covers features, specifications, calibration, DicksonWare software, and operation for accurate data recording and monitoring.
Preview DBL Data Logger Quick Start Guide - Dickson
Quick start guide for the Dickson DBL Data Logger, covering setup, configuration with DicksonWare 2.0, logging, data download, and firmware information.
Preview TSB Touchscreen Data Logger Manual - Dickson
User manual for the Dickson TSB Touchscreen Data Logger, detailing setup, data download via USB, screenshot saving, and configuration of device settings like alarms, graph display, and screen lock.
Preview Dickson DWE Internet-Connected Data Logger Quick-Start Guide
This quick-start guide provides setup and connection instructions for the Dickson DWE internet-connected data logger, enabling users to get started with Ethernet or Wi-Fi connectivity and register their device on the DicksonOne platform for online data viewing and alarm configuration.