The Bogen Multi-Zone Page Controller BG-UTI312 is engineered for multi-zone paging in one-way audio applications, specifically designed for self-amplified speaker systems. Each output is capable of providing audio for up to 150 self-amplified speakers. This unit is compatible with all standard analog port types and offers extensive configuration options for various paging needs. This manual provides essential information for the proper installation, operation, and maintenance of your BG-UTI312 unit.

Installazione è installazione

The BG-UTI312 comes with a pre-installed ZX3 module, providing three zones of paging capability. The system is expandable up to 12 zones by adding additional modules. Installation involves connecting the unit to your existing telephone system and self-ampparlanti lificati.

  • Espansione di zona: The unit is expandable up to 12 zones.
  • Interfacce telefoniche: Supports loop start trunk, ground start trunk, station access (analog ring-up), page port contact closure activation, and page port voice activation.
  • Cunfigurazione: Features a simple 2-switch interface setup for initial configuration.
  • Cuntatti Ausiliari: Programmable activation of AUX contacts is available.
  • Zone Contacts: Includes a C-form contact per zone for flexible integration.
  • Alimentazione elettrica: Utilizes a 24V DC, 1A internal power supply.
  • Speaker Capacity: Provides audio drive for up to 150 one-way self-amplified speakers per zone.
  • Terminal Strips: Pluggable terminal strips facilitate easy wiring and maintenance.
Front panel of the Bogen BG-UTI312 Multi-Zone Page Controller showing various inputs, outputs, and controls.

Image 1: This image displays the front panel of the Bogen BG-UTI312, highlighting the music inputs, limiter/threshold controls, interface type selectors, power indicators, and zone connections (1-3, 4-6, 7-9, 10-12).

Istruzzioni di funziunamentu

The BG-UTI312 offers a range of operational features for comprehensive paging and background music management.

  • Output Limiter: An adjustable output limiter with threshold control and an active indicator helps prevent audio distortion.
  • Musica di fondu: Two background music busses are available, selectable per zone. The unit features two high-impedance transformer-isolated background music inputs with stereo combining inputs for these busses.
  • Paging Zone Groups: Up to 24 programmable paging zone groups can be configured, including:
    • All-Call paging zone group.
    • Auto Select paging zone group.
    • Override paging (activated via loop start trunk or page port contact closure).
    • Night Ringer (90V and contact closure activation) with a dedicated zone group.
    • Two Tone Triggers (tone and duration selectable, closure activated) with individual zone groups. Tone options include tone burst, chime, double chime, or slow whoop.
    • Code Calling with a dedicated zone group.
  • Dialing: Supports 2 to 5 digit dialing with a flexible dialing plan for zone and zone group numbers.
  • Toni: Includes Pre-Announce Tone, Confirmation Tone, and a Setup Tone to assist in volume setting.
  • Prugrammazione: DTMF programming is used for configuration. DTMF Block helps suppress DTMF tones over the paging system.

Mantenimentu

The Bogen BG-UTI312 is designed for reliable operation with minimal maintenance.

  • Memoria: Setup data is stored in non-volatile memory, eliminating the need for a backup battery.
  • Pulizia: Keep the unit clean and free from dust. Use a soft, dry cloth for cleaning. Avoid liquid cleaners.
  • Ventilazione: Assicuratevi una ventilazione adatta intornu à l'unità per impedisce u surriscaldamentu. Ùn bluccate micca l'aperture di ventilazione.
  • Cunnessioni: Periodically check all connections to ensure they are secure. The pluggable terminal strips allow for easy inspection and re-connection.

Risoluzione di prublemi

If you encounter issues with your Bogen BG-UTI312, consider the following general troubleshooting steps. The microcontroller-based operation provides stable performance, but basic checks can resolve common problems.

  • Nisun putere: Verify the power connection and check the fuse rating (1A/125V). Ensure the 24V DC power supply is functioning correctly.
  • No Paging Audio: Check all audio input and output connections. Confirm that the correct zone is selected and that the output limiter is not set too low. Verify telephone interface connections.
  • Audio distortu: Adjust the output limiter threshold. Ensure input levels are not overdriving the system.
  • Incorrect Zone Paging: Review your dialing plan and zone group configurations. Ensure the correct digits are being dialed for the desired zone or group.
  • Background Music Issues: Check background music input connections and ensure the correct bus is selected for the zone. Verify input levels.

For persistent issues, consult a qualified technician or contact Bogen technical support.

Specificazioni

Dimensioni di u produttu19 x 7 x 6.5 inch
Pesu di l'articulu0.01 once
U fabricatoreBogen
Numero di mudelluBG-UTI312
Alimentazione elettrica24V DC, 1A (internal)
Capacità di zona3 to 12 zones (expandable with modules)
Speaker CapacityUp to 150 one-way self-amplified speakers per zone
Paging Zone GroupsFinu à 24 programmabili
MemoriaNon-volatile for setup data
Alternativa view of the Bogen BG-UTI312 Multi-Zone Page Controller.

Image 2: This image provides another perspective of the Bogen BG-UTI312, showing the overall chassis and the arrangement of its various connection points and controls.

Infurmazioni di Garanzia

The Bogen Multi-Zone Page Controller BG-UTI312 comes with a 2 anni di garanzia. Please retain your proof of purchase for warranty claims. For detailed terms and conditions, refer to the official warranty documentation provided with your product or visit the Bogen websitu.

Supportu

For technical assistance, product inquiries, or service requests, please contact Bogen customer support. Refer to the contact information provided on the Bogen official website or in the packaging materials for the most current support channels.

Documenti cunnessi - BG-UTI312

Preview Manuale d'installazione è d'usu di u cuntrollore di zona Bogen UTI312 è di l'interfaccia telefonica universale
Manuale d'installazione è d'usu per u cuntrollore di zona Bogen UTI312 cù interfaccia telefonica universale, chì detalla e so caratteristiche, a cunfigurazione è e linee guida operative per i sistemi di paging è di segnalazione multi-zona.
Preview Bogen TPU Series Telephone Paging Amplifiers: Installation and Use Manual
Comprehensive installation and use manual for Bogen TPU35B, TPU60B, TPU100B, and TPU250 telephone paging amplifiers, covering setup, wiring, operation, and specifications.
Preview Pannellu di cuntrollu principale Bogen MCP35A: Manuale d'installazione è d'usu
Stu manuale furnisce l'installazione dettagliata, u funziunamentu è e specifiche tecniche per u pannellu di cuntrollu principale Bogen MCP35A, un sistema versatile per a cumunicazione bidirezionale è a distribuzione di prugrammi in diversi ambienti.
Preview Altoparlante à tromba rientrante Bogen IH8A - Specifiche di u produttu è installazione
Dettagli cumpleti nantu à l'altoparlante à tromba rientrante Bogen IH8A, cumprese e so caratteristiche, specifiche tecniche, guida di montaggio è installazione è informazioni di garanzia limitata.
Preview Guida di cunfigurazione di u modulu interfonicu VoIP Bogen Nyquist (NQ-GA10P, NQ-GA10PV)
Guida di cunfigurazione dettagliata per i moduli interfonichi VoIP Nyquist NQ-GA10P è NQ-GA10PV di Bogen. Copre a cunfigurazione, i paràmetri di rete, l'aghjurnamenti di u firmware è u funziunamentu autonomu per i sistemi di distribuzione audio è di paging IP.
Preview Bogen VAR1 Voice-Activated Relay: Technical Specifications and Operation
Detailed specifications, installation, operation, and warranty information for the Bogen VAR1 Voice-Activated Relay, a DPDT relay device for audio signal activation and muting.