Eltako NLZ61NP-UC

Manuale d'istruzzioni di u relè temporizzatore Eltako NLZ61NP-UC

Model: NLZ61NP-UC

1. Introduzione

This manual provides detailed instructions for the installation, operation, and maintenance of the Eltako NLZ61NP-UC Timer Relay. This device is designed for building installation and control technology applications, offering precise timing functions for various electrical circuits.

2. Istruzzioni di sicurità

Osservate sempre e seguenti precauzioni di sicurezza:

  • Installation and maintenance must only be performed by a qualified electrician.
  • Disconnect power to the circuit before installation, wiring, or maintenance.
  • Ensure all connections are secure and correctly wired according to the diagram.
  • Ùn supere micca u volu specificatutage è e valutazioni attuali di u dispusitivu.
  • Prutegge u dispusitivu da l'umidità, a polvera è e temperature estreme.
  • Stu dispusitivu hè pensatu solu per l'usu interni.

3. Produttu Finituview

The Eltako NLZ61NP-UC is a compact timer relay designed for series installation. It features adjustable delay functions and robust terminal connections.

Eltako NLZ61NP-UC Timer Relay

Figura 1: Eltako NLZ61NP-UC Timer Relay. This image displays the blue, octagonal-shaped timer relay with its various terminals and adjustment potentiometers. Visible labels include 'CE', 'Eltako NLZ61NP-UC', 'A1-A2 8-230V~', 'L-N 230V~', 'RV', 'AV', '12min', 'μ 10A/250V~', and connection points for L, N, and 3.

Cumpunenti chjave:

  • A1-A2 Terminals: Cuntrollu voltage input (8-230V~).
  • L-N Terminals: Power supply input (230V~).
  • 3 Terminal: Switched output (max. 10A/250V~).
  • RV Potentiometer: Adjustable delay on release timer (0-12 minutes).
  • AV Potentiometer: Adjustable delay on activation timer (0-12 minutes).

4. Setup è Installazione

The NLZ61NP-UC is designed for series installation within an electrical distribution board or similar enclosure.

Passi di stallazione:

  1. Disconnection d'energia: Ensure the main power supply to the installation area is completely disconnected before beginning any work.
  2. Muntamentu: Mount the timer relay securely in the desired location, typically on a DIN rail within a suitable enclosure.
  3. Wiring Power Supply (L-N): Connect the live (L) and neutral (N) wires of the 230V~ power supply to the corresponding L and N terminals on the device.
  4. Wiring Control Voltage (A1-A2): Cunnette vi lu cuntrollu voltage (8-230V~) to the A1 and A2 terminals. This voltage triggers the timing functions.
  5. Wiring Output (3): Connect the load to be switched to the '3' terminal. The other side of the load should be connected to the neutral (N) or live (L) depending on the circuit design. Ensure the load's current and voltage requirements do not exceed 10A/250V~.
  6. Verificate e cunnessione: Double-check all wiring for correctness and security to prevent short circuits or malfunctions.
  7. Ripristina l'energia: Once all connections are verified, restore power to the circuit.

5. Operating Instructions

The Eltako NLZ61NP-UC features two adjustable timing functions: delay on release (RV) and delay on activation (AV).

Setting the Timer Functions:

  • RV (Delay on Release): Use the RV potentiometer to set the desired delay time after the control voltage (A1-A2) is removed. The output will remain active for the set duration before switching off. The range is 0 to 12 minutes.
  • AV (Delay on Activation): Use the AV potentiometer to set the desired delay time after the control voltage (A1-A2) is applied. The output will activate after the set duration. The range is 0 to 12 minutes.
  • Aghjustamentu: Rotate the respective potentiometer (RV or AV) to align the indicator with the desired time value on the scale (0, 2, 4, 8, 12 minutes).

The specific behavior of the relay (e.g., which delay function is active or if both can be combined) depends on the internal configuration and application. Refer to the detailed wiring diagram provided with the product for specific operational modes.

6. Mantenimentu

The Eltako NLZ61NP-UC Timer Relay is designed for long-term, maintenance-free operation under normal conditions.

  • Pulizia: Sè necessariu, asciugate delicatamente l'esternu di u dispusitivu cù un pannu asciuttu è dolce. Ùn aduprate micca detergenti abrasivi o solventi.
  • Ispezione: Periodically inspect the wiring connections for any signs of loosening or damage. Ensure the device is free from dust and debris.
  • Nisuna parte riparabile da l'utilizatori: The device contains no user-serviceable parts. Do not attempt to open or repair the unit.

7. Risoluzione di prublemi

If the timer relay does not function as expected, consider the following common issues:

Prublemu Causa Possibile Soluzione
U dispusitivu ùn risponde micca No power supply (L-N) or control voltage (A1-A2). Incorrect wiring. Check power supply and control voltage. Verify all wiring connections according to the diagram.
Output not switching Load exceeding current/voltage rating. Incorrect timing setting. Faulty load. Ensure load is within specifications. Adjust RV/AV potentiometers. Test the load independently.
Tempu incorrectu Potentiometer set incorrectly. Re-adjust the RV or AV potentiometer to the desired time.

If problems persist, contact a qualified electrician or Eltako customer support.

8. Specificazioni

Feature Detail
Marca Eltako
Numero di mudellu NLZ61NP-UC (also 2000614, 61100704)
Cuntrollu Voltage (A1-A2) 8-230V~
Voltage (LN) 230V~
Rated Current (Output 3) 10 A
Valutatu Voltage (Output 3) 250 Volts
Timing Range (RV, AV) 0-12 minuti
Materiale Plastica
Dimensioni (pacchettu) 8.9 x 6.5 x 2.2 cm
Pesu di l'articulu 40 grammi
Tipu di muntatura Series installation
Modu di funziunamentu ON-OFF-ON (Rotary switch type)

9. Garanzia è Support

For warranty information and technical support, please refer to the documentation provided with your purchase or contact Eltako customer service directly. Keep your proof of purchase for warranty claims.

Documenti cunnessi - NLZ61NP-UC

Preview Specifiche tecniche è dettagli di u produttu di i relè temporizzati è di i timer multifunzione Eltakoview
Cumprendu sopraview and technical specifications for Eltako MFZ series multifunction time relays, time relays, and timers, including models MFZ12DDX, MFZ12NP, MFZ12DX, MFZ61DX, MFZ12PMD-UC, A2Z12-UC, AVZ12DX-UC, EAW12DX-UC, PTN12-230V, RVZ12DX-UC, TGI12DX-UC, and S2U12DDX-UC. Features, functions, and technical data.
Preview Eltako SU12DBT/1+1-UC: Timer Bluetooth à 2 canali cù display è cuntrollu di l'app
Esplora l'Eltako SU12DBT/1+1-UC, un timer versatile à 2 canali cù display, Bluetooth è integrazione ELTAKO Connect-App. Dispone di cuntattu 16A/250V AC, funzione astro è montaggio su guida DIN per un cuntrollu elettricu efficiente.
Preview Eltako S2U12DDX-UC Digital Timer with Display: User Manual and Technical Specifications
Comprehensive guide to the Eltako S2U12DDX-UC digital timer, covering installation, programming, features like astro function, summer/winter time changeover, and technical data. Includes wiring diagrams and program examples.
Preview Eltako SU62PF-BT/UC Timer Bluetooth à 1 canale cù l'applicazione ELTAKO Connect
Scuprite l'Eltako SU62PF-BT/UC, un timer versatile à 1 canale cù cuntattu senza putenziale è Bluetooth. Cuntrullatelu facilmente via l'app ELTAKO Connect per una pianificazione avanzata, funzioni astro è assai di più. Ideale per l'illuminazione è l'applicazioni generali di cummutazione.
Preview Eltako Multifunction Time Switches, Time Switches, and Timers
Cumprendu sopraview and technical data for Eltako's range of multifunction time switches, time relays, and timers, including digital and analogue models with features like Bluetooth connectivity and app control. Detailed specifications, functions, and selection tables.
Preview Eltako Produkte und Preise 2012: Schaltgeräte, Netzteile & Stromzähler für Gebäudeautomation
Der Eltako Produktkatalog 2012 bietet eine umfassende Übersicht über Schaltgeräte, Netzteile und elektronische Stromzähler für die Gebäudeinstallation und Steuerungstechnik. Entdecken Sie innovative Lösungen wie Stromstoßschalter, Dimmschalter, Zeitschalter, Relais und mehr, entwickelt mit Fokus auf Energieeffizienz und Langlebigkeit.