The ICM Controls ICM856 is a motor hard start kit designed to enhance the starting performance of single-phase Permanent Split Capacitor (PSC) motors. Utilizing Positive Temperature Coefficient (PTC) technology, this device provides a significant increase in starting torque, up to 500%, facilitating reliable motor startup in various applications. It is suitable for PSC motors ranging from 1/2 hp to 10 hp.

ICM Controls ICM856 Motor Hard Start Kit

Figura 1: ICM Controls ICM856 Motor Hard Start Kit. This image displays the cylindrical hard start kit, primarily black with a blue label visible on the lower portion. The label shows 'CM85' and text indicating it's a 'Relay and Start Capacitor' for PSC units from 1/2 through 10 HP. Wires with connectors extend from the top of the unit.

2. Informazioni di sicurezza

ATTENZIONE: Electrical shock hazard. Installation and servicing should only be performed by qualified personnel. Disconnect all power to the unit before installing or servicing this device. Failure to follow these instructions may result in serious injury or death.

  • Always ensure power is disconnected at the main breaker before beginning any work.
  • Verificà voltage and current ratings are compatible with the motor and electrical system.
  • Portate l'equipaggiu di prutezzione individuale (PPE) adattatu, cumpresi occhiali di sicurezza è guanti isolanti.
  • Ùn aggirate micca i dispositi di sicurità.

3. Specificazioni

FeatureDetail
MudelluICM 856
Numeru di mudellu di l'articulu9801883
ApplicazioneSingle-Phase PSC Motors
Gamma di cavalli1/2 hp to 10 hp
Multiplicatore di coppiaFinu à 500%
TecnulugiaCoefficiente di Temperatura Pusitiva (PTC)
Dimensioni6 x 2 x 2 inch
Pesu7.04 once
U fabricatoreICM Controls

4. Istruzzioni di stallazione

  1. Disconnection d'energia: Ensure all power to the motor and associated equipment is completely disconnected at the main electrical panel. Verify with a voltagè testatore.
  2. Locate Motor Run Capacitor: Identify the existing run capacitor on the motor. The ICM856 is designed to work in parallel with this component.
  3. cablaggio: Connect the two wires from the ICM856 in parallel with the motor's run capacitor. This typically involves connecting one wire from the ICM856 to each of the two terminals of the run capacitor. Refer to the motor's wiring diagram for specific connections.
  4. Dispositivu sicuru: Mount the ICM856 securely within the motor's electrical compartment, ensuring it does not interfere with moving parts or other electrical components.
  5. Verificate e cunnessione: Double-check all wiring connections for tightness and correct polarity.
  6. Ripristina l'energia: Once installation is complete and verified, restore power to the unit.
  7. Operazione di prova: Observe the motor's startup. It should start more quickly and smoothly.

Nota: The ICM856 is intended for use only on PSC units. Do not remove any original start components unless specifically instructed by the motor manufacturer.

5. Operazione

The ICM856 operates automatically upon motor startup. When the motor attempts to start, the PTC device within the ICM856 provides an additional surge of current to the motor's start winding, significantly boosting the initial torque. As the motor reaches operating speed, the PTC device's resistance increases rapidly, effectively removing itself from the circuit, allowing the motor to run efficiently on its run capacitor. This process is seamless and requires no user intervention after installation.

6. Mantenimentu

The ICM856 is a solid-state device and generally requires no routine maintenance. However, periodic inspection of the wiring connections is recommended to ensure they remain secure and free from corrosion.

  • Annually inspect all wiring for signs of wear, fraying, or loose connections.
  • Ensure the device is free from excessive dust, dirt, or moisture accumulation.
  • If the motor exhibits starting issues after installation, first check the ICM856's connections before troubleshooting other motor components.

7. Risoluzione di prublemi

  • Motor Fails to Start:
    • Verify all power connections are secure and correct.
    • Ensure the motor's run capacitor is functioning correctly.
    • Verificate u voltage supply à u mutore.
    • Confirm the ICM856 is correctly wired in parallel with the run capacitor.
  • Motor Starts Slowly or with Difficulty:
    • Re-check all wiring connections.
    • Ensure the ICM856 is compatible with the motor's horsepower rating (1/2 hp to 10 hp).
    • Inspect the motor itself for mechanical issues or excessive load.
  • U surriscaldamentu di u dispusitivu:
    • This is unlikely for a PTC device in normal operation. If overheating occurs, immediately disconnect power and consult a qualified technician. This could indicate incorrect wiring or a fault in the motor or device.

For persistent issues, consult a qualified HVAC or electrical technician.

8. Garanzia è Support

For specific warranty information and technical support regarding your ICM Controls ICM856 Motor Hard Start Kit, please refer to the documentation provided with your purchase or consult the manufacturer's official websitu.

Produttore: ICM Controls

Documenti cunnessi - ICM 856

Preview ICM325A Single Phase Universal Head Pressure Control Installation Guide
Installation, operation, and application guide for the ICM325A Single Phase Universal Head Pressure Control. Features NFC technology for programming via the ICM Omni App, dual sensor inputs, heat pump bypass, and universal voltage.
Preview ICM401A 3-Phase Monitor: Phase Loss & Reversal Protection Installation Guide
Detailed installation guide and specifications for the ICM401A 3-phase line voltage monitor by ICM Controls. Learn about its operation, troubleshooting, and safety precautions for phase loss and reversal protection.
Preview Monitor trifase ICM402: Caratteristiche, Specifiche è Cablaggio
Infurmazioni dettagliate nantu à u Monitor Trifase ICM402, cumprese e so caratteristiche, specifiche tecniche è schemi di cablaggio. Stu dispusitivu prutege contr'à a perdita di fase, l'inversione di fase è u squilibriu di fase, ideale per i compressori.
Preview ICM325A Single Phase Universal Head Pressure Control Installation and Operation Guide
Detailed guide for installing, operating, and troubleshooting the ICM325A Single Phase Universal Head Pressure Control by ICM Controls. Features NFC connectivity, universal voltage, and variable fan speed control for HVAC systems.
Preview ICM493-60A Programmable Single-Phase Voltage Monitor with Surge Protection Installation Guide
Installation, operation, and application guide for the ICM493-60A programmable single-phase voltage monitor with surge protection by ICM Controls. Includes specifications, wiring diagrams, and setup instructions.
Preview ICM493 Programmable Single-Phase Voltage Monitor with Surge Protection Installation Guide
Detailed guide for installing, operating, and applying the ICM493 Programmable Single-Phase Voltage Monitor with Surge Protection. Covers safety, installation steps, calibration, specifications, and button functions for HVAC and industrial applications.