1. Introduzione
This manual provides essential instructions for the safe and effective use of the Testo 0560 8312 830-T1 IR Thermometer. This device is designed for non-contact measurement of surface temperatures in various industrial and trade applications. It features 12:1 optics and a dual laser for precise targeting, allowing for accurate temperature readings even on smaller objects from a safe distance.
2. Informazioni di sicurezza
Please read this section carefully before operating the device to ensure safe and proper use.
- Do not point the laser directly into eyes or at other people.
- Ùn aduprate micca u dispusitivu in atmosfere esplosive.
- Protect the device from extreme temperatures, impacts, and strong vibrations.
- Mantene u dispusitivu pulito è seccu.
- Aduprate l'apparecchiu solu per u so scopu previstu cum'è descrittu in questu manuale.
- A riparazione deve esse fatta solu da u persunale autorizatu.
3. Produttu Finituview
The Testo 830-T1 IR Thermometer is a handheld device designed for quick and accurate non-contact temperature measurements.

Figure 1: Testo 830-T1 Infrared Thermometer with included battery.

Figura 2: Fronte view of the Testo 830-T1, showing the display, measurement trigger, and control buttons.
3.1 Cumpunenti
- Sensore infrarossu: Located at the front of the device, used for non-contact temperature measurement.
- Puntatori Laser Doppiu: Two laser dots indicate the measurement spot size.
- Display: Shows temperature readings, measurement units, battery status, and other indicators.
- Trigger di misurazione: Activates the measurement and laser.
- Buttuni di cuntrollu: For navigating menus, adjusting settings (e.g., emissivity, units), and accessing functions like MIN/MAX.
- Compartimentu di batterie: Located in the handle for battery installation.
4. Setup
4.1 Installazione di batterie
- Truvate u coperchiu di u compartimentu di a batteria nantu à u manicu di u termometru.
- Aprite a tappa.
- Insert two AAA batteries, ensuring correct polarity (+/-). The device requires 2 AAA batteries, which are included.
- Chiudere in modu sicuru u coperchiu di u compartimentu di a batteria.
4.2 Initial Power-On and Unit Selection
Upon first use or after battery replacement, the device will power on. You may need to select your preferred temperature unit (Celsius or Fahrenheit).
- To change units: Typically, this involves pressing and holding a specific button (often the 'Mode' or 'Set' button, or an arrow button) while the device is off, then powering it on, or accessing a menu option. Refer to the on-screen prompts or the official Testo documentation for the exact procedure for your specific device firmware, as methods can vary.
5. Operating Instructions
5.1 Piglià una Misurazione
- Puntate u sensore infrarossu versu l'ughjettu di destinazione.
- Press and hold the measurement trigger. The dual laser pointers will activate, indicating the measurement spot.
- A lettura di a temperatura apparirà nantu à u display.
- Release the trigger to hold the last measured value (HOLD function).

Figure 3: The Testo 830-T1 in use, measuring the surface temperature of a radiator.
5.2 Understanding 12:1 Optics and Dual Laser
The 12:1 optics mean that at a distance of 12 inches, the measurement spot diameter is 1 inch. The dual laser pointers converge at the center of this measurement spot, helping you accurately identify the area being measured. This is particularly useful for measuring smaller objects or from a greater distance.
5.3 Funzione MIN/MAX
The device can display the minimum and maximum temperatures recorded during a continuous measurement. This function is useful for monitoring temperature fluctuations over a period.
- To activate MIN/MAX: Press the appropriate button (refer to your device's specific button layout, often an arrow or 'Mode' button) while taking a measurement. The display will cycle through current, minimum, and maximum values.
5.4 Ajustamentu di l'emissività
Emissivity is a measure of an object's ability to emit infrared energy. Different materials have different emissivities. For accurate readings, adjust the emissivity setting on your thermometer to match the material being measured. Common emissivity values:
- 0.95 (default for many devices): Most organic materials, painted surfaces, water, plastic.
- 0.85-0.90: Concrete, brick, rough wood.
- 0.60-0.70: Polished metals (can vary significantly).
Consult an emissivity table for specific materials. Incorrect emissivity settings will lead to inaccurate temperature readings.
6. Mantenimentu
6.1 Pulizia
To ensure optimal performance and longevity, keep the device clean.
- Wipe the device exterior with a clean, damp tela. Ùn aduprate micca detergenti abrasivi o solventi.
- Carefully clean the infrared lens with a soft, lint-free cloth or a lens cleaning wipe. Avoid scratching the lens.
6.2 Sustituzione di batterie
When the battery indicator on the display shows low power, replace the batteries promptly to avoid interruption of operation. Follow the battery installation steps in Section 4.1.
6.3 Storage
Store the thermometer in a dry, dust-free environment within the recommended temperature range (refer to specifications). If storing for extended periods, remove the batteries to prevent leakage.
7. Risoluzione di prublemi
If you encounter issues with your Testo 830-T1, refer to the following common problems and solutions:
- L'apparechju ùn s'accende micca:
- Verificate se e batterie sò inserite currettamente cù a polarità adatta.
- Sustituisce e batterie cù novi.
- Letture imprecise:
- Ensure the infrared lens is clean.
- Verify the emissivity setting matches the target material.
- Ensure the measurement distance is appropriate for the target size (12:1 optics).
- Evitate di misurà attraversu u vetru o superfici assai riflettenti.
- Laser micca visibile:
- Verificate u livellu di a bateria.
- Ensure the measurement trigger is pressed.
If problems persist, contact Testo customer support for assistance.
8. Specificazioni
| Feature | Detail |
|---|---|
| Numero di mudellu | 0560 8312 |
| Marca | Testu |
| Ottica | 12: 1 |
| Laser | Dual Laser Spot Marking |
| Funzione speciale | Misurazione senza cuntattu |
| Tipu di visualizazione | Digitale |
| Fonte d'energia | 2 batterie AAA (incluse) |
| Dimensioni di u produttu | 2.95 x 1.5 x 7.48 inch |
| Pesu di l'articulu | 0.04 once |
| Materiale Esternu | Plastica |
| Cumpunenti inclusi | Testo T2 Infrared Thermometer |
| Specificazione Met | CE, FCC, ISO 9001 |
| Tecnulugia di cunnessione | USB (Note: Functionality may require specific software/cables, not detailed here) |
9. Garanzia è Support
For warranty information, technical support, or service inquiries, please contact Testo SE & Co. directly. Details regarding specific warranty periods and terms are typically provided with the product packaging or on the manufacturer's official websitu.
Produttore: Testo SE & Co.
Per piacè conservate a vostra prova di compra per rivendicazioni di garanzia.