Dwyer A3000 Series

Dwyer Photohelic Series A3000 Pressure Switch/Gauge Instruction Manual

Model: A3000 Series

1. Introduzione

The Dwyer Photohelic Series A3000 Pressure Switch/Gauge is a versatile instrument that combines the functions of a precise pressure gauge with highly repeatable pressure switches. Utilizing the proven Magnehelic gauge design, this device accurately measures and controls positive, negative, or differential pressures of air and compatible gases.

It features two phototransistor-actuated, DPDT relays for low/high limit control, allowing for precise system management. Set points are easily adjustable via knobs located on the gauge face. The continuous gauge reading remains unaffected by switch operation, even during power loss, ensuring reliable monitoring.

2. Features

  • Combined Functionality: Operates as both a pressure gauge and a pressure switch.
  • Misurazione precisa: Employs the Magnehelic gauge design for accurate pressure readings.
  • Dual Control Relays: Includes two phototransistor-actuated DPDT relays for low/high limit control.
  • Adjustable Set Points: Easy-to-adjust set point indicators via front-mounted knobs.
  • Continuous Reading: Gauge reading is continuous and independent of switch operation or power status.
  • Optical Limit Switches: Utilizes optical limit switches for enhanced reliability and extended service life.
  • Variable Deadband: Set points can be interlocked to provide a variable deadband, suitable for fan or damper cuntrollu.
  • Custruzione robusta: Features a clear polycarbonate plastic cover and a light shield to protect internal components and ensure clear visibility.

3. Setup è Installazione

Proper installation is crucial for the accurate and reliable operation of your Photohelic Switch/Gauge. Refer to the detailed wiring diagrams and mounting instructions provided with your specific model for complete guidance.

3.1 Muntamentu

The unit is designed for vertical position calibration. Ensure the mounting surface is stable and free from excessive vibration. Secure the gauge using appropriate fasteners through the designated mounting holes.

3.2 Connessioni Pressure

Connect pressure lines to the appropriate ports on the gauge. Ensure all connections are sealed properly to prevent leaks, which can affect measurement accuracy. The gauge is suitable for air and compatible gases.

3.3 Cunnessioni Elettriche

Connect the power supply and control circuits to the DPDT relays as per the electrical schematic. Ensure all wiring complies with local electrical codes and safety standards. The optical limit switches are designed for reliability and precise switching accuracy.

Dwyer Photohelic Series A3000 Pressure Switch/Gauge with clear cover, showing internal components, gauge face, and control knobs.

Figura 1: Dwyer Photohelic Series A3000 Pressure Switch/Gauge. This image displays the device with its clear polycarbonate cover, revealing the internal circuitry, the pressure gauge face calibrated for vertical position, and the two set point adjustment knobs labeled "ZERO". The gauge face indicates a maximum pressure of 25 PSIG.

4. Operazione

4.1 Accensione

Once installed and wired, apply power to the unit. The gauge pointer will indicate the current pressure.

4.2 Ajustamentu Zero

Before operation, ensure the gauge reads zero when no pressure is applied. Use the "ZERO" adjustment screw (typically located on the front cover or near the bottom of the gauge face) to calibrate the pointer to zero.

4.3 Setting Control Points

  1. Identify the two set point knobs on the front of the gauge. These control the low and high limit switches.
  2. Rotate the desired knob to move its corresponding red set point indicator to the required pressure value on the gauge face.
  3. When the actual pressure (indicated by the main pointer) crosses a set point indicator, the associated DPDT relay will actuate, triggering the connected control circuit.
  4. The individual set point deadband is approximately one pointer width, which is less than 1% of the full scale.
  5. For applications requiring a variable deadband, the set points can be interlocked according to specific wiring diagrams.

4.4 Reading the Gauge

The gauge provides a continuous visual indication of the measured pressure. The scale is typically in inches of water column (WC) or pounds per square inch (PSIG), depending on the model. For example, the gauge face shown in Figure 1 indicates a range up to 0.50 inches of water, with markings at .20, .30, .40, and .50.

5. Mantenimentu

The Dwyer Photohelic Switch/Gauge is designed for long-term, reliable operation with minimal maintenance. However, periodic checks are recommended.

  • Pulizia: Keep the exterior of the gauge clean. Use a soft, damp cloth to wipe the clear cover. Avoid abrasive cleaners or solvents.
  • Verificazione di calibrazione: Periodically verify the zero point and accuracy of the gauge using a known pressure source. Recalibrate if necessary.
  • Integrità di cunnessione: Inspect all pressure and electrical connections for tightness and signs of wear or corrosion.
  • Cundizioni Ambientali: Ensure the operating environment remains within the specified temperature and humidity ranges to prevent damage to internal components.

6. Risoluzione di prublemi

If you encounter issues with your Photohelic Switch/Gauge, consider the following common troubleshooting steps:

  • No Gauge Reading:
    • Check pressure connections for leaks or blockages.
    • Verify that pressure is being applied to the correct ports.
  • Incorrect Gauge Reading:
    • Perform a zero adjustment.
    • Check for proper calibration against a known standard.
    • Ensure the gauge is mounted in a vertical position as calibrated.
  • Switches Not Actuating:
    • Verificate l'alimentazione elettrica di l'unità.
    • Check wiring to the DPDT relays.
    • Ensure set points are correctly positioned relative to the current pressure.
    • Inspect optical limit switches for any obstructions or damage.
  • Operazione intermittente:
    • Verificate per e cunnessione elettriche lasse.
    • Assicurà un fornimentu d'energia stabile.
    • Verify environmental conditions are stable and within operating limits.

If problems persist, contact Dwyer technical support for assistance.

7. Specificazioni

ParametruValore
Numero di mudelluA3001AV (Specific model example)
Range di pressioneVarious, from 0-.25" WC up to 30 psi (21 bar); single positive pressure to 6000 psig (413 bar)
Max. Pressione operativaStandard models: 25 psig (1.7 bar); Options: 35 (2.4) or 80 (5.5 bar) psig; 36000S models: 6000 psig (413 bar)
Cambia tipuTwo phototransistor actuated, DPDT relays
Set Point DeadbandLess than 1% of full scale (one pointer width)
Compatibilità MediaAria è gasi cumpatibili
MaterialePlastic (cover)
Pesu di l'articulu4.7 libbre (circa)
U fabricatoreStrumenti Dwyer

8. Garanzia è Support

For warranty information, technical support, or service inquiries, please contact Dwyer Instruments directly. Refer to the official Dwyer websitu o a vostra ducumentazione d'acquistu per i dettagli di cuntattu è i termini di garanzia più recenti.

Dwyer Instruments, Inc.
www.dwyer-inst.com

Documenti cunnessi - Serie A3000

Preview Guida di l'utente di l'interruttore/manometria differenziale fotoelica Dwyer Series A3000
Guida di l'utente per l'interruttore/manometru di pressione differenziale fotoelico Dwyer Series A3000, chì detalla e so specifiche, l'installazione, i cunnessione elettriche è a manutenzione.
Preview Manometru differenziale Dwyer Magnehelic® (HP/MP) - Specifiche è istruzioni
Specifiche tecniche, installazione è istruzioni operative per i manometri differenziali di pressione alta è media Magnehelic® di Dwyer (Bollettinu A-27-HP-MP). Include dettagli di u mudellu, precisione, intervallu di temperatura, montaggio, cunnessione è accessori.
Preview Manometru di pressione differenziale idronicu senza filu Dwyer Series 490W: Guida d'installazione è d'usu
Guida cumpleta per u manometru di pressione differenziale idronicu senza filu Dwyer Series 490W, chì copre e specifiche, l'installazione, u funziunamentu, a risoluzione di i prublemi è a manutenzione. Dispone di trasduttori senza filu per un equilibramentu precisu di u sistema idronicu.
Preview Trasmettitore di pressione differenziale Dwyer Series 616KX - Guida di avvio rapido
Guida di partenza rapida per u Trasmettitore di Pressione Differenziale Dwyer Serie 616KX, chì copre u montaggio, u cablaggio è a calibrazione zero. Include schemi di cablaggio per cunfigurazioni à 2 fili è 3 fili.
Preview Guida di l'utente di u trasmettitore di pressione differenziale Dwyer Series 616KX
Guida di l'utente per u Trasmettitore di Pressione Differenziale Dwyer Serie 616KX, chì detalla l'installazione, e specifiche, i cunnessione elettriche, u funziunamentu, a regulazione di u zero, a cunfigurazione di u signale di uscita, e precauzioni, a manutenzione è l'infurmazioni di garanzia.
Preview Guida di l'utente di u trasmettitore di pressione differenziale Dwyer Series 616KX
Guida di l'utente per u Trasmettitore di Pressione Differenziale Dwyer Serie 616KX, chì copre l'installazione, e specifiche, i cunnessione elettriche, a regulazione di u zero, i cambiamenti di u signale di uscita, e precauzioni è l'infurmazioni di garanzia.