Dwyer WMT2-B-C-11-1

Dwyer WMT2-B-C-11-1 Multi-Jet Water Meter with Pulsed Output User Manual

1. Produttu Finituview

The Dwyer Series WMT2 Multi-Jet Water Meter is engineered for commercial and industrial applications requiring accurate water flow measurement. Its multi-jet design ensures reliable performance and accuracy across a broad range of flow rates, including low-flow conditions. The meter is built for durability and minimal maintenance, even in challenging environments. It features a magnetically driven, hermetically sealed register that prevents leaks and fogging, completely isolating it from the water flow. A reed switch, activated by a magnet on the dial, generates a pulsed output directly proportional to the flow rate. This output is suitable for remote monitoring of flow rate or totalization and can be integrated with PLCs, counters, data loggers, and SCADA systems.

Dwyer WMT2-B-C-11-1 Multi-Jet Water Meter with Pulsed Output

Image 1.1: The Dwyer WMT2-B-C-11-1 Multi-Jet Water Meter, showing its brass body, blue casing, and the meter face with a pulsed output connection.

2. Informazioni di sicurezza

WARNING: This product is NOT FOR POTABLE WATER USE. The brass construction contains lead in excess of low-lead limits. Do not use this meter in applications where water will be consumed by humans or animals.

Always ensure proper installation by qualified personnel to prevent leaks and ensure accurate operation. Adhere to all local codes and regulations regarding plumbing and electrical connections.

3. Caratteristiche di u produttu

  • Cuncepimentu Multi-Jet: Provides high accuracy and wide flow range capabilities.
  • Pulsed Output: Equipped with a reed switch for remote monitoring and integration with control systems.
  • Registru ermeticamente sigillatu: Magnetically driven, preventing leaks and fogging for clear readings.
  • Custruzzione durabile: Designed for long service life in commercial and industrial settings.
  • Brass Body: Robust construction for demanding applications.

4. Specificazioni

SpecificazioneValore
MudelluWMT2-B-C-11-1
Dimensione di l'accoppiamentu1" BSPT
Rate Massimu di flussu7 m³/h
Rate nominale di flussuda 0.25 a 3.5 m³/h
Transitional Flow Rate0.07 m³/h
Pulsu Pulsu1 gallon per pulse
Temperature Massima104 ° F (40 ° C)
Pressione massima232 psi (16 bar)
Cunnessioni ElettricheColor-coded lead wires, 4.5' (1.5 m) long
Pesu di l'articulu13.52 liri
U fabricatoreDwyer Instruments, Inc.

5. Setup è Installazione

Installation of the Dwyer WMT2-B-C-11-1 water meter should be performed by a qualified professional in accordance with all applicable local and national plumbing and electrical codes.

  1. Selezzione di u locu: Choose a location that is easily accessible for reading and maintenance, protected from freezing temperatures, and where the meter can be installed horizontally with the flow arrow pointing in the direction of water flow.
  2. Pipe Preparation: Ensure the piping is clean and free of debris before installation. Use appropriate pipe thread sealant on the 1" BSPT couplings.
  3. Installazione meccanica: Install the meter into the pipeline, ensuring a tight, leak-free connection. The meter should be installed in a straight run of pipe, ideally with at least 10 pipe diameters of straight pipe upstream and 5 pipe diameters downstream for optimal accuracy.
  4. Cunnessione elettrica: Connect the color-coded lead wires from the pulsed output to your remote monitoring system (PLC, counter, data logger, SCADA). Refer to your system's documentation for specific wiring requirements. Ensure all electrical connections are secure and properly insulated.
  5. Verifica di Fuga: After installation, slowly open the water supply to the meter and check for any leaks at the connections.

6. Operating Instructions

Once installed and the water supply is restored, the Dwyer WMT2-B-C-11-1 meter will begin measuring water flow. The meter's register displays the totalized volume of water that has passed through it. The pulsed output provides an electrical signal (1 pulse per gallon) that can be used by external devices for remote monitoring and data logging.

  • Reading the Meter: The main display on the meter face shows the total accumulated volume. Smaller dials may indicate fractional units for more precise readings.
  • Pulsed Output: The reed switch generates a pulse for every gallon of water that flows through the meter. Connect the lead wires to a compatible device (e.g., PLC, counter) to record these pulses and calculate flow rate or total volume remotely.
  • Direzzione di u flussu: Ensure water flows in the direction indicated by the arrow on the meter body for accurate measurement.

7. Mantenimentu

The Dwyer WMT2-B-C-11-1 Multi-Jet Water Meter is designed for relatively maintenance-free operation. However, periodic checks are recommended to ensure continued accuracy and performance:

  • Ispezione visuale: Regularly inspect the meter for any signs of physical damage, leaks, or corrosion.
  • Chiarezza di u Registru: Ensure the hermetically sealed register remains clear and free of fogging, allowing for easy reading.
  • Integrità di cunnessione: Verify that all plumbing and electrical connections remain secure and free of corrosion.
  • Pulizia: If the exterior of the meter becomes dirty, wipe it with a damp tela. Ùn aduprate micca chimichi duri o detergenti abrasivi.

No internal user-serviceable parts are present. Do not attempt to disassemble the meter, as this will void the warranty and may damage the device.

8. Risoluzione di prublemi

If you encounter issues with your Dwyer WMT2-B-C-11-1 water meter, consider the following troubleshooting steps:

  • No Flow Reading:
    • Check if water is actually flowing through the pipe.
    • Verify the meter is installed with the flow arrow in the correct direction.
    • Inspect for any blockages upstream or downstream of the meter.
  • Letture inaccurate:
    • Ensure the meter is installed horizontally.
    • Check for air in the pipeline, which can affect accuracy.
    • Verify that the flow rate is within the meter's specified nominal flow range.
  • No Pulsed Output:
    • Confirm that water is flowing through the meter and the mechanical register is advancing.
    • Check the electrical connections of the lead wires to your monitoring device.
    • Ensure the monitoring device is correctly configured to receive pulses.
  • Perdite à e cunnessione:
    • Tighten connections carefully, ensuring not to overtighten.
    • If necessary, drain the system, reapply pipe thread sealant, and reassemble.

If problems persist after performing these checks, contact Dwyer Instruments, Inc. technical support for assistance.

9. Garanzia è Support

For information regarding the product warranty, technical support, or replacement parts, please contact Dwyer Instruments, Inc. directly or visit their official website. Keep your purchase receipt and product model number (WMT2-B-C-11-1) readily available when seeking support.

Documenti cunnessi - WMT2-B-C-11-1

Preview Manometru digitale portatile Dwyer Series 477AV: Specifiche, installazione è istruzioni operative
Guida cumpleta à u manometru digitale portatile Dwyer Series 477AV, chì copre e specifiche, l'installazione, l'istruzzioni operative, e caratteristiche è a manutenzione per e misurazioni di pressione, flussu è velocità.
Preview Trasmettitore di flussu elettromagneticu à inserzione IEF serie Dwyer: Istruzioni d'installazione è d'usu
Stu documentu furnisce specifiche cumplete, guide d'installazione è istruzioni operative per u Trasmettitore di Flussu Elettromagneticu à Inserzione IEF di a Serie Dwyer, descrivendu in dettagliu e so caratteristiche, applicazioni è protokolli di cumunicazione per a misurazione di a velocità di i fluidi industriali.
Preview Dwyer Flow Measurement and Control Products: A Comprehensive Selection Guide
Explore Dwyer Instruments' extensive range of flowmeters, flow switches, and flow transmitters. This guide provides detailed specifications and selection criteria to help identify the optimal product for your industrial or commercial application.
Preview Guida di avvio rapidu di i misuratori di portata Visi-Float VFC di a serie Dwyer
Una guida rapida per i misuratori di portata Visi-Float di a serie Dwyer VFC, chì furnisce istruzioni essenziali per l'installazione, u montaggio è a lettura, è ancu precauzioni operative impurtanti.
Preview Misuratori d'energia à ultrasoni TUF di a serie Dwyer: Monitoraghju di flussu è temperatura
Specifiche dettagliate, caratteristiche, applicazioni è informazioni d'ordine per i contatori d'energia à ultrasoni TUF di a serie Dwyer, cuncepiti per un monitoraghju precisu di u flussu è di a temperatura cù cumunicazione Modbus® o BACnet.
Preview Applicazioni di i prudutti di l'automatizazione di i prucessi Dwyer è Guide di Selezzione
Esplora a guida cumpleta di Dwyer Instruments per l'automatizazione di i prucessi, chì copre l'applicazioni di i prudutti è a selezzione per HVAC, trattamentu di l'acqua, petroliu è gasu, è assai di più. Scuprite suluzioni di strumentazione per pressione, flussu, livellu, temperatura è qualità di l'aria.