Lutron MS-OPS6M2-DV-GR

Lutron Maestro MS-OPS6M2-DV-GR Occupancy Sensing Switch Instruction Manual

Model: MS-OPS6M2-DV-GR | Brand: Lutron

1. Introduzione

The Lutron Maestro Occupancy Sensing Switch is designed to automatically turn lights on and off based on room occupancy, providing convenience and energy savings. This switch supports multi-location control and is compatible with various lighting loads and general-purpose fans.

Funzioni chjave:

  • Multi-location, single pole or 3-way operation.
  • Supports up to 6-Amps for lighting (120 Volts or 277 Volts) and 3-Amps for fans.
  • Compatible with incandescent, halogen, magnetic and electronic low-voltage, non-dim LED, and non-dim fluorescent bulbs, as well as general purpose fans.
  • Automatic light control based on occupancy.
  • Requires a ground wire for installation.

2. Impurtante Information Safety

WARNING: RISK OF ELECTRIC SHOCK. May result in serious injury or death. Turn off power at circuit breaker or fuse before installing. Ensure power is OFF before proceeding with installation.

  • Installa in cunfurmità cù tutti i codici elettrichi naziunali è lucali.
  • This device must be installed by a qualified electrician if you are unsure about the wiring process.
  • Do not use with loads exceeding the specified ampera.
  • Solu per usu interni.

3. Cuntenutu di u pacchettu

Your package should include the Lutron Maestro Occupancy Sensing Switch and an instruction guide. Additional accessories like wall plates are sold separately.

Fronte view of the Lutron Maestro Occupancy Sensing Switch in gray

Figura 1: Fronte view of the Lutron Maestro Occupancy Sensing Switch in gray.

Torna view of the Lutron Maestro Dual Voltage Sensor showing wiring points

Figura 2: Torna view of the Lutron Maestro Dual Voltage Sensor, highlighting wiring points and features like the tap switch and sensor LED.

4. Installazione

Before beginning, ensure power is turned OFF at the circuit breaker. Use a voltage tester to confirm the power is off before touching any wires.

4.1 Single-Pole Installation

  1. Spegne l'energia: Locate your circuit breaker and turn off the power to the switch you are replacing. Double-check with a voltagè testatore.
  2. Eliminate l'interruttore esistente: Unscrew and carefully pull out the existing switch from the wall box.
  3. Identificà i fili: You should have two wires from the wall connected to your old switch, plus a ground wire. Identify if you have a neutral (typically white) or ground (bare copper or green) wire coming out of the wall box.
  4. Wire the new sensor:
    • If a neutral wire is available: Remove the green sleeve from the sensor's white wire and connect the sensor's white wire to the neutral wire from the wall. Connect the sensor's bare wire to the ground wire from the wall.
    • If no neutral wire is available: Leave the green sleeve on the sensor's white wire. Connect both the sensor's green wire (with sleeve) and the sensor's bare wire to the ground wire from the wall.
    • Connect one of the two wires from your wall to one of the black wires on your new sensor.
    • Connect the remaining wire from the wall to the other black wire on your sensor.
    • Place a wire cap on the blue wire from the sensor. This is not used in a single-pole application.
  5. Mount the sensor: Carefully push all wires back into the wall box and secure the sensor with screws.
  6. Installa a piastra murale: Attach your wall plate (sold separately).
  7. Ripristinà a putenza: Riattivate u putere à u circuit breaker.

Video 1: Installation guide for Lutron Maestro 5 Amp & 6 Amp Sensor Switch in a single-pole configuration. This video demonstrates the step-by-step process of replacing an existing switch with the Maestro sensor, including safety precautions, wire identification, and final mounting.

4.2 Multi-Location (3-Way) Installation

For multi-location setups (where two switches control the same light), you will install the Maestro sensor in one location and a Maestro companion switch (MA-AS or MSC-AS) or update an existing 3-way switch in the other location(s).

  1. Spegne l'energia: Spegne l'energia à u circuit breaker.
  2. Remove existing switches: Unscrew and carefully pull out the existing switches from both wall boxes.
  3. Identify wires at the Maestro sensor location: You should have three wires plus a ground connected to your old switch. Take a piece of electrical tape and tag the wire connected to the different colored screw of the existing switch (typically a black wire).
  4. Wire the Maestro sensor: Follow the neutral/ground wiring steps as in single-pole installation. Connect the tagged wire (from the different colored screw) to one of the black wires on your new sensor. Connect the remaining two wires from the wall to the remaining black wire and the blue wire on the sensor. Make a note of the color wire you connect to the blue wire, as this will be important for the second location.
  5. Mount the Maestro sensor: Secure the sensor in its wall box.
  6. Wire the second location (Companion Switch):
    • At the second location, identify the common wire (the one connected to the different colored screw on the old switch). Attach this common wire to the black screw on the companion switch.
    • Identify the same color wire you connected to the blue wire in the first location. Connect this wire to the blue screw on the companion switch.
    • Connect the remaining two wires each to the black and brass screws on the companion switch. (The black and brass screws are interchangeable in this location).
    • Cunnette u filu verde à a terra.
  7. Wire the second location (Update Existing Switch with Jumper Wire):
    • At the second location, identify the common wire (the one connected to the different colored screw on the old switch). Remove only this tagged wire from the switch.
    • Identify the wire that is the same color as what you attached to the blue wire in the sensor location. Leave this wire connected.
    • Remove the remaining wire from the switch.
    • Connect the two removed wires together, along with the yellow jumper wire (included in package).
    • Connect the other end of the yellow jumper wire to the black screw on the existing switch.
  8. Mount switches and restore power: Secure all switches in their wall boxes, install wall plates, and turn the power back on at the circuit breaker.

Video 2: Installation guide for Lutron Maestro 5 Amp & 6 Amp Switch in multi-location (3-way) setups. This video details how to wire the main sensor and companion switches or update existing switches for multi-point control.

5. Installazione è cunfigurazione

After installation, your new sensor will take approximately one minute to power up. During this time, you can still manually turn the lights on and off using the paddle switch. Once powered up, it will begin automatic operation.

For detailed instructions on how to change the timeout settings, sensitivity, and sensor mode (occupancy/vacancy), please refer to the full product manual available on the Lutron websitu: lutron.com/OPS5M.

6. Operazione

The Maestro Occupancy Sensing Switch offers both automatic and manual control:

  • Funzionamentu automaticu: The sensor detects motion and ambient light to automatically turn lights on when you enter a room and off when you leave.
  • Cuntrollu Manuale: You can manually turn the lights on or off at any time by tapping the large paddle switch.

Video 3: Lutron Sensors: Key Benefits. This video highlights the advanced XCT Technology for superior sensitivity, detecting both major and fine motion, ensuring lights stay on when needed.

7. Mantenimentu

To maintain optimal performance and appearance of your Lutron Maestro switch:

  • Pulite cù un soffiu, damp tela. Ùn aduprate micca detergenti abrasivi o solventi.
  • Ensure the sensor lens is clear of obstructions for accurate motion detection.

8. Risoluzione di prublemi

If your Maestro Occupancy Sensing Switch is not functioning as expected, consider the following:

  • Lights not turning on/off automatically: Check the sensor's sensitivity and timeout settings. Ensure there are no obstructions blocking the sensor's view.
  • Lights flickering or not working: Verify all wiring connections are secure and correct. Ensure the power is on at the circuit breaker. Confirm the load (bulbs/fan) is compatible with the switch.
  • Problemi di putenza: If the switch has no power, check the circuit breaker.

For more detailed troubleshooting, refer to the full product manual or contact Lutron customer support.

9. Specificazioni

Dimensions of the Lutron Maestro Dual Voltage Sensor: 4.7 inches (119 mm) high and 2.9 inches (75 mm) wide

Figure 3: Dimensions of the Lutron Maestro Dual Voltage Sensore.

FeatureDetail
Numero di mudelluMS-OPS6M2-DV-GR
Modu di funziunamentuautumàticu
Valutazione attuale6 Amps
Voltage120 Volt / 277 Volt
Tipu di Circuitu3-Way/Single Pole
Tipu di attuatorePulsante
Metudu di cuntrolluTocca
CuloreGrisgiu
Wattage720 watts
Dimensioni di u produttu2.4 x 4 x 5.8 inch
Pesu di l'articulu0.32 once
Dispositivi compatiblesIncandescent bulbs, Halogen bulbs, Magnetic low-voltage bulbs, Electronic low-voltage bulbs, Non-dim LED bulbs, Non-dim fluorescent bulbs, General purpose fans

10. Garanzia è Support

For warranty information and customer support, please visit the official Lutron websitu o cuntattate direttamente u so serviziu clienti. Conservate a vostra ricevuta d'acquistu per e richieste di garanzia.

Lutron Customer Support: www.lutron.com/support

Documenti cunnessi - MS-OPS6M2-DV-GR

Preview Interruttore di Sensore di Occupazione/Vacante Lutron Maestro: Specifiche, Caratteristiche è Diagrammi di Cablaggio
Specifiche cumplete, caratteristiche, tecnulugia XCT avanzata, impostazioni persunalizate, matrice di selezzione, dimensioni, montaggio, funziunamentu è diagrammi di cablaggio dettagliati per l'interruttore di sensore di presenza/vacanza Lutron Maestro. Amparate nantu à e so capacità di risparmiu energeticu è l'opzioni d'installazione.
Preview Guida d'installazione di l'interruttore di sensore Lutron Maestro cù interruttore cumpagnu
Questa guida furnisce struzzioni dettagliate per l'installazione è u cablaggio di l'interruttori di sensore Lutron Maestro cù interruttori associati per applicazioni unipolari, à 3 vie è à 4 vie. Copre i diagrammi di cablaggio, l'identificazione di l'interruttori è e precauzioni di sicurezza impurtanti.
Preview Guida d'installazione di l'interruttore di rilevamentu di occupazione Lutron Maestro
Istruzzioni d'installazione dettagliate è specifiche per l'interruttori di rilevamentu di occupazione Lutron Maestro MS-OPS2 è MS-VPS2. Copre u cablaggio, i paràmetri persunalizati, note di sicurezza impurtanti è informazioni di garanzia limitata.
Preview Guida d'installazione di l'interruttore di rilevamentu di occupazione Lutron
Una guida cumpleta per l'installazione di l'interruttore di rilevamentu di presenza Lutron (MS-OPS2, MS-VPS2), chì copre u cablaggio, a cunfigurazione è a risoluzione di i prublemi.
Preview Guida d'installazione di l'interruttore di sensore à doppia tecnulugia Lutron Maestro
Guida cumpleta d'installazione per l'interruttore di sensore à doppia tecnulugia Lutron Maestro (MS-A102, WMS-A102, MS-A102-V, WMS-A102-V). Copre u cablaggio, a cunfigurazione, i paràmetri persunalizati, a risoluzione di i prublemi è note di sicurezza impurtanti per i cuntrolli di l'illuminazione di occupazione è di posti vacanti.
Preview Guida d'installazione è cunfigurazione di l'interruttore di sensore di occupazione Lutron MAESTRO MS-OPS5M/MS-VPS5M
Guida cumpleta per l'installazione è a cunfigurazione di l'interruttori di sensori di occupazione Lutron MAESTRO MS-OPS5M è MS-VPS5M. Amparate nantu à e funzioni, u cablaggio, i paràmetri persunalizati è e note di sicurezza impurtanti.