1. Introduzione

Grazie per l'acquistuasing the A&D Waterproof Interval Timer AD-5709TL. This versatile timer is designed for various applications, from kitchen use to sports training, offering precise timing and robust features. Its IPX7 waterproof rating ensures durability in wet environments, while its multi-timer and repeat functions provide flexibility for complex timing needs. Please read this manual carefully to ensure proper use and maintenance of your device.

A&D Waterproof Interval Timer AD-5709TL, front view chì mostra u display digitale è i buttoni.

Figura 1.1: Fronte view of the A&D Waterproof Interval Timer AD-5709TL, displaying its digital screen and control buttons.

2. Funzioni chjave

A hand holding the timer, demonstrating its magnetic attachment to a pile of paper clips.

Figure 2.1: The timer's magnetic backing allows for easy attachment to metal surfaces, as shown with paper clips.

The timer floating in water with rubber ducks, demonstrating its IPX7 waterproof capability.

Figure 2.2: The timer is shown submerged in water, highlighting its IPX7 waterproof rating for use in wet environments.

3. Setup

3.1. Cuntenutu di u pacchettu

3.2. Installazione di batterie

The timer uses one CR2032 lithium battery. A battery is included for initial monitoring purposes. For long-term use, it is recommended to replace it with a new battery.

  1. Truvate u compartimentu di a batteria nant'à u spinu di u timer.
  2. Use a coin or a flat tool to twist the battery cover counter-clockwise to open.
  3. Inserite a batteria CR2032 cù u latu pusitivu (+) versu l'altu.
  4. Rimpiazzate u coperchio di a batteria è giratelu in sensu orariu per fissallu.
Torna view of the timer showing the battery compartment and a CR2032 battery next to it.

Figura 3.1: Posteriore view of the timer, illustrating the battery compartment and the CR2032 battery for installation.

3.3. Accensione iniziale

Once the battery is correctly installed, the timer will automatically power on and display '00:00'.

4. Operazione

4.1. Funzioni di u buttone

PulsanteFunzione
1分 (1 Minute)Adds 1 minute to the timer setting.
10秒 (10 Seconds)Adds 10 seconds to the timer setting.
10分 (10 Minutes)Adds 10 minutes to the timer setting.
スタート/ポーズ (Start/Pause)Starts or pauses the timer.
ストップ (Stop)Stops the timer and resets it to the last set time or zero.
メモリ (Memory)Recalls stored timer settings.
リセット (Reset)Resets the timer to 00:00. (Often combined with Stop or a long press of Stop)

4.2. Setting a Countdown Timer

  1. Ensure the timer display is '00:00'. If not, press the Stop buttone per resettate.
  2. Aduprà u 1分, 10秒, è 10分 buttons to set your desired countdown time. The maximum setting is 99 minutes 50 seconds, and the minimum is 10 seconds.
  3. Press u スタート/ポーズ buttone per inizià u contu à rebours.
  4. To pause the countdown, press スタート/ポーズ di novu. Appughjatelu una volta di più per ripiglià.
  5. When the timer reaches zero, the alarm will sound (buzzer for 5 or 30 seconds) and the red LED will blink for approximately 30 seconds.
  6. Press u Stop button to silence the alarm and reset the timer to the last set time.

4.3. Using Multiple Timers (Sequential Operation)

The AD-5709TL can store and run up to 8 sequential timer settings. This is ideal for interval training or multi-step processes.

  1. Set the first timer duration using the 1分, 10秒, è 10分 i buttoni.
  2. Press u メモリ button to save this setting as Step 1. The display will show '00:00' or the next step number.
  3. Repeat the process to set and save up to 8 steps. Each time you press メモリ, it saves the current setting and moves to the next step number.
  4. Once all steps are set, press スタート/ポーズ to begin the sequence. The timer will count down each step consecutively.
  5. The alarm will sound after each step completes, and the timer will automatically proceed to the next step.
Diagram showing a sequence of 5 timer steps (20 min, 7 min, 16 min, 11 min, 3 min) with a loop for repeating 1 to 999 times or infinitely.

Figura 4.1: Esample of sequential timer operation with multiple steps and repeat functionality.

4.4. Repetite Funzione

After setting your sequential timers (or a single timer), you can set the number of times the sequence should repeat.

  1. After setting your timer steps (as described in 4.3), press the メモリ button repeatedly until the display shows the repeat count setting (e.g., 'RPT 001').
  2. Aduprà u 1分, 10秒, è 10分 buttons to adjust the repeat count from 1 to 999.
  3. To set for permanent (infinite) repeat, continue pressing the buttons until 'RPT INF' or similar is displayed.
  4. Press スタート/ポーズ to start the repeating timer sequence.

4.5. Count-up Function

To use the count-up function:

  1. Ensure the timer display is '00:00'.
  2. Press u スタート/ポーズ button. The timer will immediately start counting up from 00 minutes 00 seconds.
  3. Press スタート/ポーズ again to pause the count-up.
  4. Press u Stop button to stop the count-up and reset the display to '00:00'.

5. Mantenimentu

5.1. Pulizia

Per pulisce u timer, asciugatelu cù un pannu dolce èamp cloth. Do not use abrasive cleaners, solvents, or immerse the device in water beyond its IPX7 rating. Ensure the battery compartment is securely closed before cleaning with moisture.

5.2. Sustituzione di batterie

When the display becomes dim or the timer functions erratically, it's time to replace the battery. Follow the steps in Section 3.2 for battery installation. Always use a new CR2032 lithium battery.

5.3. Storage

Store the timer in a cool, dry place away from direct sunlight and extreme temperatures. If storing for an extended period, it is recommended to remove the battery to prevent leakage.

6. Risoluzione di prublemi

PrublemuCausa PossibileSoluzione
U cronometru ùn si accende micca.A batteria hè morta o installata in modu incorrectu.Replace the battery with a new CR2032, ensuring correct polarity.
U display hè scuru o sfarfalla.Batteria bassa.Sustituisce a bateria.
L'alarma hè troppu forte.Buzzer volume is fixed.The buzzer volume is approximately 65dB at 15cm and cannot be adjusted. Consider using the LED alarm only if available (not a direct feature on this model, but a general suggestion).
U timer ùn risponde micca à e pressioni di i buttoni.Problema di software tempurale o batteria bassa.Eliminate è inserite torna a batteria. Se u prublema persiste, rimpiazzate a batteria.
Sequential timers do not advance.Incorrect setting or timer paused.Ensure all steps are correctly saved using the Memory button. Check if the timer is paused.

7. Specificazioni

SpecificazioneDetail
Numero di mudelluAD-5709TL
Dimensioni (L x W x H)6.8 x 6.8 x 1.6 cm
PesuCirca. 60 g
CuloreBiancu
Range di paràmetriMax 99 minutes 50 seconds, Min 10 seconds
Number of TimersUp to 8 sequential timers
Repetite u conte1 to 999 times, or infinite
Alarm Duration (Buzzer)5 seconde / 30 seconde
Alarm Duration (LED)Approx. 30 seconds blinking red LED
Volume BuzzerApprox. 65dB (at 15cm distance)
Prestazione impermeabileEquivalente IPX7
Fonte d'energiaCR2032 Lithium Battery x 1
Diagram showing the timer's dimensions (68mm x 68mm x 16mm), weight (approx. 60g), battery type (CR2032), and large display, with text indicating alarm by sound and LED.

Figure 7.1: Visual representation of the timer's dimensions, weight, battery information, and alarm features.

8. Garanzia è Support

This product is covered by a standard manufacturer's warranty. For warranty claims, technical support, or inquiries, please contact A&D customer service through their official websitu o u rivenditore da quale avete acquistatu u pruduttu. Per piacè cunservate a vostra prova d'acquistu per a validazione di a garanzia.

For more information, visit the official A&D websitu: www.aandd.co.jp

Documenti cunnessi - AD-5709TL

Preview AD-5709/AD-5709-E Waterproof Timer Instruction Manual
Comprehensive instruction manual for the A&D AD-5709/AD-5709-E Waterproof Timer, detailing features, safety precautions, operation, maintenance, and specifications. Includes guidance on using count-up and count-down functions, battery replacement, and product care.
Preview Manuale d'istruzzioni di l'unità di pesatura di pruduzzione A&D AD-4212C Series
Manuale d'istruzzioni cumpletu per l'unità di pesatura di pruduzzione di a serie A&D AD-4212C, chì detalla e caratteristiche, l'installazione, u funziunamentu, e specifiche è a risoluzione di i prublemi per l'applicazioni di pesatura industriale.
Preview A&D AD-4212D-S Production Weighing Unit Simplified Instruction Manual
Simplified instruction manual for the A&D AD-4212D-S Production Weighing Unit, detailing its features, installation procedures, specifications, and communication capabilities.
Preview A&D AD-5705BK / AD-5705RE デジタルタイマー 取扱説明書
A&D AD-5705BK および AD-5705RE デジタルタイマーの取扱説明書。製品仕様、カウントダウン/カウントアップ機能、時計設定、電池交換、および重要な注意事項について詳述します。
Preview Manuale d'istruzzioni di l'indicatore di pesatura A&D AD-4406
Manuale d'istruzzioni cumpletu per l'indicatore di pesatura A&D AD-4406, chì copre l'installazione, e caratteristiche, a calibrazione, e funzioni è e specifiche di l'interfaccia.
Preview AD-8526 Ethernet Converter: Instruction Manual and Connectivity Guide
Comprehensive guide for the A&D AD-8526 Ethernet Converter, detailing setup, specifications, cable requirements, and software for connecting weighing instruments to a computer network.