This manual provides comprehensive instructions for the safe and effective use of your ARDO Calypso-to-Go Double Electric Breast Pump. Please read this manual thoroughly before first use and retain it for future reference.

Image: The Ardo Calypso-to-Go Double Electric Breast Pump, showing the main unit, bottles, breast shells, and the included messenger bag.
Ciò chì hè inclusu
The Calypso-to-Go package includes the following components:
- 1x Calypso Breastpump unit
- 2x Pumpsets with 150ml bottles and 26mm Breastshells
- 2x Lids with removable insert
- 2x 31mm Breastshells
- 2x 28mm Breastshells (fits in 31mm breastshell)
- 2x Optiflow inserts (fits in 31mm breastshell)
- 2x Extra lip valves
- 1x Brush for cleaning
- 1x Bottle Holder
- 1x adattatore di rete
- 1x Instruction manual and quick guide
- 8x Bottles (total, including those with pumpsets)
- 1x Messenger bag
- 1x Cool bag
- 3x Ice packs
- 1x Amaryll hand pump

Imagine: Un dettagliu view of all items included in the Ardo Calypso-to-Go kit, such as the pump unit, various breast shell sizes, bottles, cleaning brush, power adapter, and the travel bag with cooling elements.
Setup è Assemblea
- Componenti puliti: Before first use, disassemble and clean all parts that come into contact with breast milk according to the "Maintenance and Cleaning" section.
- Assemble Pumpset:
- Attach the chosen breast shell (26mm, 28mm, or 31mm) to the connector.
- Insert the Optiflow soft massage insert (if desired) into the breast shell.
- Attach the lip valve to the valve head.
- Screw the bottle onto the pumpset.
- Connect the tubing to the pumpset and the pump unit.
- Opzioni di putenza: The Calypso-to-Go offers three power options:
- Adattatore di rete: Connect the power adapter to the pump unit and a wall outlet.
- Batterie AA: Inserite 6 batterie AA in u compartimentu di a batteria.
- Optional Car Adapter: (Not included in standard package) Connect a compatible car adapter for use in a vehicle.
- Placement: Place the pump unit on a stable, flat surface. Ensure the tubing is not kinked.

Image: Various components of the breast pump, including different sized breast shells, bottles, and the main pump unit, ready for assembly.
Istruzzioni di funziunamentu
The ARDO Calypso-to-Go breast pump features 64 individual settings for vacuum and cycle to ensure a comfortable and efficient pumping experience.
- Power On: Pulsà u buttone di accensione (⏻) to turn on the pump. The display will illuminate.
- Adjust Vacuum (Suction Strength): Use the "Vacuum" up (▲) è falà (▼) buttons to increase or decrease the suction strength. Start with a low setting and gradually increase to a comfortable level.
- Adjust Cycles (Frequency): Use the "Cycles" up (▲) è falà (▼) buttons to adjust the pumping frequency. Higher cycles are often used for let-down, while lower cycles are for milk expression.
- Find Your Ideal Setting: Experiment with different combinations of vacuum and cycle settings to find what works best for your body. The goal is effective milk expression without discomfort.
- Shabbat Mode: The Calypso is Shabbat-mode capable with an external Shabbat clock (not included). Refer to the specific instructions for using this feature if applicable.
- Spegnimentu: Mantene premutu u buttone di putenza (⏻) to turn off the pump.

Image: A close-up of the Calypso breast pump's control panel, highlighting the display and the "Vacuum" and "Cycles" adjustment buttons.
The pump's Vacuum Seal Technology ensures a closed system, preventing breast milk or impurities from entering the connecting tube or pump unit. This design provides reliable protection against contamination and infection.
Mantenimentu è Pulizia
A pulizia è a manutenzione adeguate sò cruciali per l'igiene è a longevità di u vostru tiralatte.
- Disunzione: After each use, disassemble all parts of the pumpset that come into contact with breast milk (breast shells, Optiflow inserts, valve heads, lip valves, bottles).
- Pulizia:
- Rinse all disassembled parts with cold water immediately after use.
- Wash parts in warm, soapy water using the provided cleaning brush.
- Sciacquate bè cù acqua pulita.
- Air dry on a clean surface or use a dedicated drying rack.
- Sterilizazione: Sterilize parts regularly (e.g., daily) by boiling for 5 minutes, using a steam sterilizer, or a dishwasher (top rack, if dishwasher safe).
- Unità di pompa: The pump unit and tubing do not come into contact with breast milk due to the closed system. Wipe the exterior of the pump unit with a damp cloth as needed. Do not immerse the pump unit in water.
- Conservazione: Store clean and dry components in a clean, dry place when not in use.
Risoluzione di prublemi
If you encounter issues with your ARDO Calypso-to-Go breast pump, please refer to the following common solutions:
- Nisuna aspirazione o aspirazione debule:
- Check that all pumpset components are correctly assembled and securely fitted.
- Ensure the lip valve is clean, undamaged, and properly seated.
- Verify that the tubing is securely connected to both the pumpset and the pump unit, and is not kinked or damaged.
- If using batteries, check if they are correctly inserted and have sufficient charge. Replace if necessary.
- A pompa ùn si accende micca:
- Ensure the mains adapter is securely plugged into both the pump and a working power outlet.
- If using batteries, check if they are correctly inserted and have sufficient charge. Replace if necessary.
- Discomfort During Pumping:
- Adjust the vacuum (suction strength) to a lower, more comfortable level.
- Ensure you are using the correct breast shell size. Refer to the sizing guide in your quick start manual or consult a lactation professional.
- Ensure proper breast positioning within the breast shell.
- Bassa pruduzzione di latte:
- Ensure you are using the correct breast shell size.
- Experiment with different vacuum and cycle settings to find the most effective combination for you.
- Ensure you are relaxed and comfortable during pumping. Stress can affect milk flow.
- Consult a lactation professional if low milk output persists.
If these steps do not resolve the issue, please contact ARDO customer support.
Specificazioni
| Numero di mudellu | Calypso-To-Go |
| Dimensioni di u produttu | 12 x 10 x 12 inch |
| Pesu | 1 Pound (pump unit) |
| Opzioni di putenza | Mains adapter, 6 AA batteries (required), Optional car adapter |
| Materiale | BPA Free components |
| Tipu di sistema | Closed System (Vacuum Seal Technology) |
| Settings | 64 adjustable vacuum and cycle settings |
| U fabricatore | Ardo medical, Inc. |
Garanzia è Supportu
The ARDO Calypso-to-Go breast pump is designed for durability and reliability. ARDO medical, Inc. offers a warranty for this product.
- Periudu di garanzia: The pump unit is covered by a warranty of 400 hours of use or 1 year, whichever is longer.
- Politica di ritornu: Products may be eligible for a refund or replacement within 90 days of purchase, subject to retailer's terms.
- Disclaimer legale: Dichjarazioni riguardanti i supplementi dietetichi ùn sò micca stati valutati da a FDA è ùn sò micca destinati à diagnosticà, trattà, curà o prevene ogni malatia o cundizione di salute.
For further assistance, product registration, or to inquire about specific warranty details, please contact Ardo medical, Inc. directly or visit their official store: