Eberle KLR-E 7010

Eberle KLR-E 7010 Fancoil Thermostat User Manual

Model: KLR-E 7010 | Brand: Eberle

1. Produttu Finituview

The Eberle KLR-E 7010 is a bimetal thermostat designed for controlling fancoil units. It provides precise temperature regulation and offers control over fan speed and operating mode (heating or cooling). This manual provides essential information for the safe and efficient installation, operation, and maintenance of your thermostat.

Eberle KLR-E 7010 Fancoil Thermostat front view cù cuntrolli

Figura 1: Fronte view of the Eberle KLR-E 7010 Fancoil Thermostat. The image displays the front panel of the thermostat, which is white with the 'EBERLE' brand name in the top left. On the right side, there is a large rotary dial for temperature setting, marked in degrees Celsius from 5 to 30. An arrow indicates the current setpoint. On the left, there are two horizontal slide switches. The top switch controls the fan speed, with icons representing different fan speeds. The bottom switch selects between heating (wavy lines), off (center), and cooling (snowflake) modes.

2. Importanti Instructions Safety

3. Guida d'installazione

3.1. Cuntenutu di u pacchettu

Verificate chì tutti i cumpunenti sò presenti prima di principià l'installazione:

3.2. Istruzzioni di Montaggio

  1. Sceglie u locu: Choose an interior wall location, approximately 1.5 meters (5 feet) above the floor, away from direct sunlight, drafts, heat sources, or areas with poor air circulation.
  2. Disconnect Power: Turn off the power to the fancoil unit at the main circuit breaker. Verify that power is off using a voltagè testatore.
  3. Piastra di basa separata: Separate cù cura u coperchiu frontale di u termostatu da a so piastra di basa.
  4. Piastra di basa di muntatura: Position the base plate on the wall and mark the drilling locations. Drill holes and insert wall anchors if necessary. Secure the base plate to the wall using the provided mounting screws.
  5. cablaggio: Refer to the wiring diagram (Section 3.3) and connect the electrical wires to the appropriate terminals on the base plate. Ensure all connections are tight and correct.
  6. Attaccate a copertina frontale: Once wiring is complete and verified, carefully reattach the front cover to the base plate, ensuring it clicks securely into place.
  7. Ripristina l'energia: Riavvitate a corrente à l'interruttore principale.

3.3. Schema di Cablaggio

The Eberle KLR-E 7010 thermostat is designed for 230 Volts systems. Due to variations in fancoil unit configurations and local electrical codes, a generic wiring diagram cannot be provided here. It is imperative that a qualified electrician performs all wiring to ensure proper functionality and safety. The electrician should consult the specific wiring instructions provided with your fancoil unit and the terminal markings on the thermostat's base plate.

4. Operating Instructions

4.1. Controls Overview

The thermostat features three primary controls:

4.2. Setting Temperature

To set the desired room temperature, rotate the large dial clockwise or counter-clockwise until the indicator arrow points to your preferred temperature in degrees Celsius. The thermostat will then work to maintain this temperature.

4.3. Fan Speed ​​Control

Use the upper left slide switch to adjust the fancoil's fan speed:

4.4. Mode Selection (Heating/Cooling)

Use the lower left slide switch to select the operating mode:

5. Mantenimentu

The Eberle KLR-E 7010 thermostat requires minimal maintenance.

6. Risoluzione di prublemi

If you experience issues with your Eberle KLR-E 7010 thermostat, consult the table below for common problems and potential solutions.

PrublemuCausa PossibileSoluzione
Thermostat not responding / No powerNo power at the circuit breaker; Loose wiring connection.Check the circuit breaker and ensure it is in the 'ON' position. Verify all wiring connections are secure (consult a qualified electrician).
Fancoil not heating/coolingIncorrect mode selected; Temperature setpoint too high/low; Fancoil unit malfunction.Ensure the mode switch is set to 'Heating' or 'Cooling' as desired. Adjust the temperature setpoint appropriately. Check the fancoil unit for operational issues.
Fan ùn funziona miccaFan speed switch set to 'Off' (if applicable); Fancoil unit fan malfunction.Ensure the fan speed switch is set to a desired speed (Low, Medium, or High). Check the fancoil unit's fan for issues.
Lettura di temperatura imprecisaThermostat located near heat/cold source or draft.Relocate the thermostat to a more suitable position if possible, away from direct influences.

If the problem persists after attempting these solutions, contact a qualified technician or customer support.

7. Specifiche tecniche

8. Garanzia infurmazione

This Eberle KLR-E 7010 thermostat is covered by the manufacturer's standard warranty. The specific terms and duration of the warranty may vary by region and retailer. Please retain your proof of purchase for warranty claims. For detailed warranty information, refer to the documentation provided at the time of purchase or contact your retailer.

9. Assistenza Clienti

For technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact the retailer from whom you purchased the product or visit the official Eberle website for support contact information. When contacting support, please have your product model (KLR-E 7010) and proof of purchase readily available.

Documenti cunnessi - KLR-E 7010

Preview Controllore di Temperatura di Pavimentu Eberle FIT 3F: Manuale d'Installazione è d'Usu
Uttene struzzioni dettagliate d'installazione è d'usu per u regulatore di temperatura di u pavimentu Eberle FIT 3F. Amparate e so caratteristiche, a prugrammazione, e specifiche tecniche è a risoluzione di i prublemi per un riscaldamentu à u pavimentu efficiente.
Preview Istruzzioni d'installazione è d'usu di u termostatu Eberle UTE 3500 è UTE 3800-U
Stu documentu furnisce struzzioni cumplete d'installazione è d'usu per i termostati Eberle UTE 3500 è UTE 3800-U. Copre e specificazioni tecniche, i diagrammi di cablaggio, e procedure di cunfigurazione, e cunfigurazioni di i casi d'usu, i menu d'installazione è d'utilizatore, è a cunnessione di a casa intelligente via Matter WiFi.
Preview Istruzzioni d'installazione è d'usu di UTE 3500 è UTE 3800-U
Guida cumpleta per l'installazione è u funziunamentu di i cuntrolli di temperatura elettronichi UTE 3500 è UTE 3800-U, chì copre i dati tecnichi, u cablaggio, i preimpostazioni, i paràmetri di l'installatore è a cunfigurazione Matter WiFi.
Preview UTE 3500 & UTE 3800-U Installation and Operating Instructions | Eberle
Comprehensive installation and operating manual for the Eberle UTE 3500 and UTE 3800-U smart thermostats, covering setup, wiring, configuration, and features like Matter WiFi connectivity.
Preview Ricevitore di radiofrequenza plug-in Eberle INSTAT 868-a1S - Manuale d'installazione è d'usu
Istruzzioni cumplete d'installazione è d'usu per u ricevitore di radiofrequenza plug-in Eberle INSTAT 868-a1S. Amparate cumu cunnette, aduprà è risolve i prublemi di questu dispositivu per u cuntrollu di a temperatura in spazii residenziali.
Preview Regolatore di temperatura Eberle FRe 525 31/i per riscaldamentu à pavimenti - Manuale d'installazione è d'usu
Guida cumpleta d'installazione è d'usu per u termostatu Eberle FRe 525 31/i, cuncipitu per sistemi di riscaldamentu à pavimentu elettrici è à acqua calda. E caratteristiche includenu specifiche tecniche, schemi di cablaggio, gestione di i guasti di i sensori è limitazione di l'intervallu di temperatura.