1. Introduzione
This manual provides essential information for the proper installation, operation, and maintenance of the Notifier LEM-320 Loop Expander Module. The LEM-320 is designed to expand the capacity of compatible fire alarm control panels by providing additional Signaling Line Circuits (SLCs).
2. Informazioni di sicurezza
Always observe the following safety precautions during installation, operation, and maintenance of the LEM-320 module:
- L'installazione deve esse effettuata da persunale qualificatu in cunfurmità cù tutti i codici elettrici lucali è naziunali.
- Disconnect all power sources before installing or servicing the module.
- Handle electronic components with care to prevent electrostatic discharge (ESD) damage.
- Assicuratevi di mette a terra curretta per prevene i periculi elettrici.
- Refer to the main fire alarm control panel manual for system-specific safety instructions.
3. Produttu Finituview
The Notifier LEM-320 is a Loop Expander Module designed to interface with a compatible Loop Control Module (LCM-320) to extend the system's capacity for addressable devices. It functions as a daughter board, providing additional even-numbered Signaling Line Circuits (SLCs) to the fire alarm control panel.

Figura 3.1: Top view of the Notifier LEM-320 Loop Expander Module, showing various integrated circuits and components.

Figura 3.2: Angulu view of the Notifier LEM-320 module, highlighting the component layout and connection points.

Figura 3.3: U fondu view of the Notifier LEM-320 module, showing the circuit board traces and mounting points.
4. Installazione
The LEM-320 module is designed to be mounted as a daughter board onto a compatible Notifier LCM-320 Loop Control Module. Follow these steps for proper installation:
- Preparazione: Ensure all power to the fire alarm control panel is disconnected. Refer to the LCM-320 manual for specific power-down procedures.
- Truvà a pusizione di muntatura: Identify the designated mounting headers on the LCM-320 board for the LEM-320 daughter board.
- Align Module: Carefully align the connectors on the LEM-320 with the corresponding headers on the LCM-320. Ensure correct orientation to prevent damage.
- Modulu sicuru: Gently press the LEM-320 into place until it is firmly seated. Use any provided standoffs or screws to secure the module to the LCM-320, if applicable.
- Verificate e cunnessione: Double-check that all connections are secure and that the module is properly seated.
- Power Up: Restore power to the fire alarm control panel according to the manufacturer's instructions.
- Configurazione di u Sistema: Configure the fire alarm control panel to recognize the newly installed LEM-320 module and its associated SLCs. Refer to the control panel's programming manual for detailed instructions.
Nota: Improper installation can lead to system malfunction or damage. Always consult the specific documentation for the LCM-320 and the main fire alarm control panel.
5. Operazione
The Notifier LEM-320 Loop Expander Module operates as an integral part of the fire alarm control panel system. Once properly installed and configured with the LCM-320, it extends the system's capacity by providing additional Signaling Line Circuits (SLCs).
- SLC Expansion: The LEM-320 enables the connection of more addressable fire alarm devices (e.g., smoke detectors, heat detectors, manual pull stations, monitor modules) to the system.
- Comunicazione: It facilitates communication between the connected SLC devices and the main fire alarm control panel via the LCM-320.
- Integrazione di u sistema: The module's operation is fully integrated with the control panel's software, allowing for centralized monitoring and control of all connected devices.
No direct user interaction is typically required with the LEM-320 module itself after initial installation and system configuration. Its function is to provide the necessary hardware expansion for the fire alarm system.
6. Mantenimentu
The Notifier LEM-320 module is designed for reliable, long-term operation with minimal maintenance. However, periodic inspection and adherence to general electronic component care practices are recommended:
- Ispezione visuale: Ispettate periodicamente u modulu per ogni segnu di danni fisichi, cunnessione allentate o accumulazione eccessiva di polvere.
- Pulizia: If necessary, gently clean the module using a soft, dry, lint-free cloth. Avoid using liquids or abrasive cleaners. Ensure power is disconnected before cleaning.
- Cundizioni Ambientali: Ensure the module operates within the specified environmental conditions (temperature, humidity) of the fire alarm control panel enclosure.
- Test di sistema: Regular testing of the entire fire alarm system, including all connected SLC devices, should be performed by qualified technicians as per local codes and manufacturer guidelines.
Attenzione: Do not attempt to repair the module yourself. Refer all servicing to qualified Notifier service personnel.
7. Risoluzione di prublemi
If the fire alarm system experiences issues related to SLC communication or device recognition after the LEM-320 installation, consider the following troubleshooting steps:
- Verificazione di l'energia: Verify that the fire alarm control panel has stable power and that the LCM-320 is powered correctly.
- Module Seating: Ensure the LEM-320 is securely seated on the LCM-320's connectors. Re-seat the module if necessary (with power disconnected).
- Integrità di cablaggio: Check the wiring of all SLC devices connected to the expanded loops for shorts, opens, or incorrect connections.
- Configurazione di u Sistema: Confirm that the fire alarm control panel's programming correctly recognizes the LEM-320 and the expanded SLCs. Verify device addressing.
- Indicatori LED: Observe any diagnostic LEDs on the LCM-320 or the main control panel for error codes or status indications. Refer to the respective manuals for interpretation.
- Consult Manuals: Always refer to the specific troubleshooting sections of the LCM-320 manual and the main fire alarm control panel manual for detailed diagnostic procedures.
If issues persist, contact Notifier technical support or a certified fire alarm technician.
8. Specificazioni
| Feature | Detail |
|---|---|
| Numero di mudellu | LEM-320 (Part Number: NLEM320) |
| U fabricatore | NOTIFIER |
| Funzione | Loop Expander Module for LCM-320 |
| Muntà | Daughter board to LCM-320 |
| Pesu di l'articulu | 2 liri |
| Batterie necessarie | Innò |
| Batterie incluse | Innò |
| Quantità di pacchettu | 1 |
9. Garanzia è Support
For warranty information regarding the Notifier LEM-320 Loop Expander Module, please refer to the official Notifier warranty statement provided with your product or available on the Notifier websitu. I termini di garanzia coprenu tipicamente i difetti di materiali è di fabricazione in cundizioni d'usu nurmale.
For technical support, service, or to report issues, please contact your authorized Notifier distributor or Notifier technical support directly. Ensure you have your product model number (LEM-320) and any relevant system information ready when contacting support.
Notifier Contact Information:
Please visit the official Notifier websitu per i dettagli di cuntattu è e risorse di supportu più recenti. www.notifier.com