deleyCON MK899

deleyCON MK899 Infrared Motion Detector User Manual

Mudellu: MK899

1. Introduzione

This manual provides detailed instructions for the installation, operation, and maintenance of your deleyCON MK899 Infrared Motion Detector. This device is designed for indoor use to automatically control lighting based on detected movement and ambient light levels. Please read this manual thoroughly before installation and use to ensure proper function and safety.

2. Istruzzioni di sicurità

  • L'installazione deve esse effettuata da un elettricista qualificatu in cunfurmità cù i codici è i regulamenti elettrici lucali.
  • Disconnect power at the circuit breaker before installing or servicing the device.
  • Do not install in areas with high humidity or direct water exposure (IP20 rating: suitable for indoor, dry environments only).
  • Assicurà u fornimentu voltage matches the specifications of the motion detector.
  • Do not open the device housing or attempt to modify the internal components.

3. Cuntenutu di u pacchettu

Verificate chì tutti i cumpunenti sò presenti in u pacchettu:

  • 1x deleyCON Infrared Motion Detector (MK899)
  • 1x Manuale d'utilizatore
  • 2x Screws with dowels for mounting

4. Produttu Finituview

The deleyCON MK899 motion detector features a compact design for ceiling surface mounting. It includes adjustable settings for light duration and ambient light sensitivity.

Close-up of deleyCON MK899 motion detector showing sensor, TIME and LUX adjustment dials, and control LED.

Image 1: Primu pianu view of the motion detector's sensor, adjustment dials, and control LED. The dials are labeled 'TIME' for light duration and 'LUX' for light sensitivity.

  1. Sensore: Detects infrared radiation from moving objects.
  2. TIME Adjustment Dial: Controls the duration the light remains on after motion detection.
  3. LUX Adjustment Dial: Sets the ambient light threshold for activation.
  4. Control Lamp (LED): Indicates motion detection and operational status.

5. Specificazioni

FeatureSpecificazione
Numero di mudelluMK899
MarcadeleyCON
Dimensioni di u produttu (L x W x H)11.5 x 11.5 x 5.8 cm
Pesu161 grammi
CuloreBiancu
Tipu di putenzaAC (corrente alternante)
Tipu di muntaturaSurface Mount (Ceiling)
Angulu di rilevazione360°
Gamma massima di rilevazione6 metri
Classe di prutezzioneIP20 (Usu Internu)
Adjustable Light Duration (TIME)10 seconde à 7 minuti
Adjustable Ambient Brightness (LUX)
Dispositivi compatiblesLights (Lamps, LEDs)
Gamma di temperatura di funziunamentu60 Degrees Celsius (Note: This value seems unusually high for an operating range. Please refer to product packaging for exact operating temperature limits.)

6. Setup è Installazione

The deleyCON MK899 is designed for surface mounting on ceilings. Ensure power is disconnected before proceeding.

6.1 Muntà u dispusitivu

  1. Separate the mounting plate from the main unit by twisting or unlatching as indicated by the device design.
  2. Position the mounting plate on the desired ceiling location. Mark the drilling points through the holes on the plate.
  3. Drill holes at the marked positions and insert the provided dowels.
  4. Secure the mounting plate to the ceiling using the provided screws.
daretu view of the deleyCON MK899 motion detector showing the detachable mounting plate and wiring terminals.

Image 2: daretu view of the motion detector, illustrating the detachable mounting plate and the internal wiring terminals.

6.2 Schema di cablaggio

Follow the wiring diagram carefully. Incorrect wiring can damage the device or connected lights.

Wiring diagram for the deleyCON MK899 motion detector, showing connections for Live (L), Neutral (N), and Load (A) to a light bulb.

Image 3: Wiring schematic for the motion detector. Connect the Live (L) and Neutral (N) input wires, and the Load (A) output wire to the light fixture. The diagram shows L (Phase/Hot), N (Neutral/Ground), and A (Consumer/Lamp).

  • Connect the Live (L) wire from your power supply to the 'IN~ L' terminal.
  • Connect the Neutral (N) wire from your power supply to the 'IN~ N' terminal.
  • Connect the Live wire of your light fixture (Load) to the 'OUT~ LOAD' terminal.
  • Connect the Neutral wire of your light fixture to the 'IN~ N' terminal (shared with incoming neutral).

After wiring, attach the main unit to the mounting plate, ensuring it is securely fastened.

7. Operating Instructions

Once installed and powered, the motion detector will enter a warm-up period (typically 30-60 seconds) during which it may activate randomly. After this, it will be ready for operation and adjustment.

7.1 Adjusting Light Duration (TIME)

The 'TIME' dial controls how long the connected light remains on after motion is detected and the detection zone is clear. Rotate the dial to set the desired duration:

  • '-' (Minimum): Circa 10 seconde.
  • '+' (Maximum): Circa 7 minuti.

7.2 Adjusting Ambient Light Sensitivity (LUX)

The 'LUX' dial determines the ambient light level at which the motion detector will activate. This prevents the light from turning on during daylight hours when not needed.

  • '☼' (Sun Symbol - Maximum): The detector will activate regardless of ambient light (day and night).
  • '☽' (Moon Symbol - Minimum): The detector will only activate in very low light conditions (dusk/night).

Adjust the dial to your preferred setting. For testing, set it to the 'Sun' symbol to ensure functionality during daylight.

7.3 Zona di rilevazione

The deleyCON MK899 offers a 360° detection angle with a maximum range of 6 meters, ideal for comprehensive coverage in indoor spaces.

Illustration showing the 360-degree detection area and 6-meter range of the motion detector.

Image 4: Visual representation of the motion detector's 360° detection angle and maximum 6-meter range, suitable for indoor environments.

8. Mantenimentu

The deleyCON MK899 motion detector requires minimal maintenance.

  • Pulizia: Asciugate l'apparechju cù un pannu dolce è asciuttu. Ùn aduprate micca detergenti abrasivi o solventi.
  • Ispezione: Periodically check for any visible damage or loose connections.
  • The device contains no user-serviceable parts. Do not attempt to disassemble it.

9. Risoluzione di prublemi

Sè avete prublemi cù u vostru rilevatore di muvimentu, riferitevi à i seguenti prublemi è suluzioni cumuni:

PrublemuCausa PossibileSoluzione
Light does not turn on when motion is detected.
  • Incorrect LUX setting (too high).
  • Nisuna putenza à u dispusitivu.
  • Cablaggio difettoso.
  • Muvimentu fora di a portata di rilevazione.
  • Adjust LUX dial towards the 'Moon' symbol.
  • Verificate l'interruttore automaticu è i cunnessione di l'alimentazione.
  • Verify wiring according to the diagram.
  • Ensure motion occurs within 6m range and 360° angle.
A luce ferma continuamente.
  • Muvimentu custante in a zona di rilevazione.
  • Incorrect TIME setting (too long).
  • Malfunzionamentu di u dispusitivu.
  • Ensure no continuous movement or heat sources (e.g., heating vents) are within the detection zone.
  • Adjust TIME dial towards the '-' symbol.
  • If problem persists, disconnect power and consult a professional.
A luce s'accende troppu spessu o à casu.
  • LUX setting too sensitive.
  • Small animals or objects causing detection.
  • Drafts or temperature fluctuations.
  • Adjust LUX dial towards the 'Sun' symbol.
  • Relocate the detector or adjust its position to avoid unwanted triggers.
  • Ensure stable environmental conditions.

10. Garanzia è Support

For warranty information and technical support, please refer to the documentation provided with your purchase or visit the official deleyCON websitu. Conservate a vostra prova d'acquistu per qualsiasi reclamazione di garanzia.

Documenti cunnessi - MK899

Preview deleyCON HDMI Wanddose 4K Benutzerhandbuch
Umfassendes Benutzerhandbuch für die deleyCON HDMI Wanddose 4K. Enthält Installationsanleitungen, technische Daten, Sicherheitshinweise und Informationen zur Produktkonformität für Modelle wie MK3164.
Preview deleyCON Mini Infrarød Bevægelsesdetektor Quickstart Guide
Denne quickstart guide giver e oversigt over deleyCON's mini infrarøde bevægelsesdetektor, includesive installationsvejledning, sikkerhedsinstruktioner og tekniske specifikationer. Lær hvordan du korrekt installerer og bruger din bevægelsesdetektor til optimal ydeevne.
Preview deleyCON Audio Cinch Kabel: Benutzerhandbuch und technische Informationen
Umfassendes Benutzerhandbuch für deleyCON Audio Cinch Kabel (RCA-Kabel). Erfahren Sie mehr über Productdetails, technische Spezifikationen, Sicherheitshinweise und Konformitätserklärungen für Modelle wie MK4085. Enthält Informationen zur Installation, Verwendung und Entsorgung.