SMT UH-50

SMT Ultrasonic Homogenizer UH-50 Instruction Manual

Modellu: UH-50

1. Introduzione

This manual provides essential information for the safe and efficient operation of the SMT Ultrasonic Homogenizer UH-50. Please read this manual thoroughly before using the device and keep it for future reference.

The SMT Ultrasonic Homogenizer UH-50 is a compact and lightweight device designed for laboratory applications requiring ultrasonic homogenization. Its key features include a space-saving design, a lightweight vibrator (approximately 160g), and a hand pulser for convenient control of ultrasonic vibration. The system automatically adjusts output to maintain a constant amplitude, adapting to variations in sample load and pressure.

2. Informazioni di sicurezza

WARNING: This is a professional-use product. It should only be operated by trained personnel in a laboratory setting.

  • No Dry Operation: Do not operate the ultrasonic vibrator without it being immersed in a liquid sample. Dry operation can cause damage to the device.
  • Assicuratevi chì u dispusitivu sia piazzatu nantu à una superficia stabile è piana.
  • Connect the device to a grounded power outlet with the specified voltage (AC100V, 50/60Hz).
  • Avoid direct contact with the vibrating tip during operation.
  • Ùn smuntate micca o pruvate micca di riparà l'unità da per voi. Cuntattate un persunale di serviziu qualificatu.
  • Keep the unit away from flammable materials and excessive moisture.

3. Cumponenti è cuntrolli di u pruduttu

The SMT Ultrasonic Homogenizer UH-50 consists of a main control unit and an ultrasonic vibrator with a hand pulser. Familiarize yourself with the components and controls shown below.

SMT Ultrasonic Homogenizer UH-50 main unit and vibrator

Figure 1: SMT Ultrasonic Homogenizer UH-50 Overview
This image displays the main control unit of the SMT Ultrasonic Homogenizer UH-50 on the left, connected to the ultrasonic vibrator on the right. The control unit features a "MONITOR" display, a "POWER" switch, "CONSTANT" and "HAND" mode selector, "TUNE" and "OUTPUT" adjustment knobs. A yellow label on top of the main unit warns against dry operation. The vibrator is a slender, metallic component with a tip.

Descrizzione di u pannellu di cuntrollu:

  • Interruttore POWER: Accende è spegne l'unità.
  • MONITOR Display: Shows the current output level or other operational parameters.
  • CONSTANT/HAND Selector:
    • COSTANTE: Continuous ultrasonic operation.
    • MANU: Operation controlled by the hand pulser switch.
  • Manopola TUNE: Adjusts the ultrasonic frequency for optimal performance.
  • Manopola OUTPUT: Controls the ultrasonic power output (amplitudine).
  • Hand Pulser: A switch located on the vibrator cable for convenient start/stop of ultrasonic vibration when in HAND mode.

4. Setup

  1. Unpacking: Eliminate cù cura tutti i cumpunenti da l'imballu. Verificate chì tutte e parti sianu presenti secondu a lista d'imballu.
  2. Placement: Place the main control unit on a stable, flat, and dry surface, ensuring adequate ventilation around the unit.
  3. Connect Vibrator: Connect the ultrasonic vibrator cable securely to the designated port on the main control unit.
  4. Cunnessione di putenza: Ensure the POWER switch is in the "OFF" position. Connect the power cord to the main control unit and then to a grounded AC100V, 50/60Hz power outlet.
  5. Ispezione iniziale: Before first use, visually inspect the vibrator tip for any damage or wear.

5. Operating Instructions

Always ensure the vibrator tip is immersed in the sample liquid before starting operation to prevent damage from dry running.

  1. Preparate SampLe: Piazzà u vostru sample in an appropriate vessel. Ensure the vessel is suitable for ultrasonic treatment and can withstand the energy generated.
  2. Immerse Vibrator: Carefully immerse the tip of the ultrasonic vibrator into the sample liquid. Ensure the tip is sufficiently submerged but not touching the bottom or sides of the vessel.
  3. Power On: Turn the POWER switch to the "ON" position. The MONITOR display should illuminate.
  4. Selezziunà u Modu:
    • For continuous operation, set the selector to "CONSTANT".
    • For intermittent operation controlled by the hand pulser, set the selector to "HAND".
  5. Adjust TUNE: Slowly adjust the TUNE knob until the MONITOR display shows the highest stable reading, indicating optimal resonance.
  6. Set OUTPUT: Adjust the OUTPUT knob to the desired ultrasonic power level. The system will automatically control the output to maintain a constant amplatitudine.
  7. Start Homogenization:
    • In "CONSTANT" mode, homogenization will start immediately.
    • In "HAND" mode, press and hold the switch on the hand pulser to start homogenization. Release the switch to stop.
  8. Prucessu di monitoru: Observe the homogenization process. Adjust OUTPUT or TUNE as necessary.
  9. Cumpiimentu: Once homogenization is complete, turn the OUTPUT knob to minimum, then turn the POWER switch to "OFF".
  10. Clean Vibrator: Carefully remove the vibrator from the sample and clean it immediately according to the maintenance instructions.

6. Mantenimentu

Regular maintenance ensures the longevity and optimal performance of your SMT Ultrasonic Homogenizer UH-50.

  • Cleaning the Vibrator Tip: After each use, thoroughly clean the vibrator tip to prevent sample residue buildup. Use appropriate cleaning agents for the materials being processed. Rinse with distilled water and dry completely.
  • Pulizia di l'unità principale: Wipe the exterior of the main control unit with a soft, damp cloth. Do not use abrasive cleaners or allow liquids to enter the unit.
  • Ispezione: Periodically inspect the vibrator tip, cable, and connectors for any signs of wear, damage, or corrosion. Replace damaged parts immediately.
  • Conservazione: Conservate l'unità in un ambiente pulitu è ​​asciuttu quandu ùn hè micca in usu.

7. Risoluzione di prublemi

If you encounter issues with your SMT Ultrasonic Homogenizer UH-50, refer to the following common problems and solutions:

  • Nisun putere:
    • Check if the power cord is securely connected to both the unit and the power outlet.
    • Assicuratevi chì a presa di corrente hè funziunale.
    • Verify the POWER switch is in the "ON" position.
  • No Ultrasonic Vibration:
    • Ensure the vibrator tip is properly immersed in liquid.
    • Check the TUNE and OUTPUT knob settings. Adjust TUNE for optimal resonance.
    • If in "HAND" mode, ensure the hand pulser switch is pressed.
    • Inspect the vibrator cable for damage.
  • Output bassu o inconsistente:
    • Adjust the TUNE knob to find the optimal frequency.
    • Increase the OUTPUT knob setting.
    • Ensure the vibrator tip is clean and free of damage.
    • Verificate u sample volume and viscosity are within appropriate limits for the device.

If the problem persists after attempting these solutions, please contact SMT customer support or your local distributor for assistance.

8. Specificazioni

FeatureSpecificazione
Numero di mudelluUH-50
Dimensione (unità principale)182 × 320 × 110 mm
Alimentazione elettricaAC100V, 50/60Hz, 2A
Forza di output50 W
Massimu Amplatitudine40 µm
Frequency20 kHz
Vibrator Outer Dimensionsφ32 × 297 mm
Included Tip3mm (Titanium Alloy)
Vibrator WeightCirca. 160 g
Pesu di u produttu3.16 kg
Usu di batterieInnò

9. Garanzia è Support

Specific warranty information for the SMT Ultrasonic Homogenizer UH-50 is not provided in this document. Please refer to your purchase agreement or contact your local SMT distributor for details regarding warranty coverage and technical support.

Per più assistenza, pudete ancu visità u SMT Brand Store on Amazon.co.jp.

Documenti cunnessi - UH-50

Preview SMT Ultra-Pure ClO₂ Fast Release Gas Deodorizer for Odor Elimination
Discover SMT's Ultra-Pure Chlorine Dioxide (ClO₂) Fast Release Gas Deodorizer, an effective and eco-friendly solution for eliminating tough odors in various spaces. Learn about its rapid action, micro-reactor technology, and versatile applications for homes, offices, and warehouses.
Preview SMT Ultra-Pure ClO2 Extended Release Gas Deodorizer | Odor Control Solutions
Discover the SMT Ultra-Pure ClO2 Extended Release Gas Deodorizer, a humidity-activated solution for continuous odor control and air purification. Learn how it neutralizes tough odors, improves air quality, and its key features for various applications.
Preview Manuale d'istruzzioni di l'analizzatore di cimentu à ultrasoni OFITE Modellu 120-50
Stu manuale d'istruzzioni furnisce una guida cumpleta per l'usu di l'analizzatore di cimentu à ultrasoni OFITE Modellu 120-50. Copre l'installazione, a cunfigurazione di u software, e procedure operative, a manutenzione, a risoluzione di i prublemi è l'infurmazioni di garanzia per un'analisi precisa di a resistenza di u cimentu.
Preview UH Series Installation Manual: Gas-Fired Unit Heater Guide
Comprehensive installation, operation, and maintenance manual for Detroit Radiant Products UH Series gas-fired unit heaters. Covers safety, specifications, installation, troubleshooting, and parts for models UH-30, UH-45, UH-60, UH-60-SS, and UH-75.
Preview Outdoor Patio Heaters UH Series Gas Unit Heater Installation Manual
Comprehensive installation, operation, maintenance, and safety guidelines for the Outdoor Patio Heaters UH Series gas unit heaters. Covers product specifications, troubleshooting, and parts.
Preview Custodia subacquea AOI UH-OM5 II: Guida generale è caratteristiche
Guida generale cumpleta per a custodia subacquea AOI UH-OM5 II, chì detalla l'installazione di a camera, a compatibilità di e porte, l'analisi di u vacuum, i testi di perdite d'acqua, e cunnessione in fibra ottica è l'istruzzioni di cura per e camere OM SYSTEM OM-5 Mark II.