YA-MAN HRF-18T

YA-MAN RF Core EX HRF-18T Body Beauty Device Instruction Manual

Model: HRF-18T

1. Introduzione

The YA-MAN RF Core EX HRF-18T is a home-use beauty device designed for body, face, and bust care. It integrates three popular beauty salon technologies: Cavitation, Radio Frequency (RF), and Electrical Muscle Stimulation (EMS). This device is waterproof (IPX7 equivalent), allowing for use during bath time.

This manual provides essential information for the safe and effective use of your device. Please read it thoroughly before first use and keep it for future reference.

2. Precauzioni di sicurità

U mancatu rispettu di queste istruzioni di sicurezza pò causà ferite o malfunzionamenti di u dispusitivu.

2.1 Do Not Use If You Have Any of the Following Conditions:

  • Persons using medical electrical equipment (e.g., implanted pacemakers, life support systems, wearable medical devices).
  • Persons with heart disease, disorders, or suspected conditions.
  • Persons unable to express their will.
  • Persons unable to perceive temperature or stimulation.
  • Persons from early pregnancy until immediately after childbirth.
  • Persons with autoimmune diseases.
  • Persons with uterine diseases such as endometriosis or uterine fibroids.

2.2 Consult a Doctor Before Use If You Have Any of the Following Conditions:

  • Acute diseases.
  • Malati infizziosi.
  • Tumuri maligni.
  • Febrile diseases.
  • High blood pressure or blood disorders.
  • Fever.
  • Sensory impairment due to severe peripheral circulatory dysfunction, such as diabetes.
  • Neurological disorders.
  • Malatie di a pelle o dermatite atopica.
  • Undergoing medical treatment and taking medication.
  • Allergic constitution, contact dermatitis, or other pre-existing skin conditions, or those concerned about their skin during use.

2.3 Do Not Use On Areas Other Than Specified or On the Following Areas:

  • Fractured areas.
  • Areas with metal implants due to surgical procedures (plastic, orthopedic, cosmetic).
  • Areas with internal bleeding, swelling, scabs, etc., after cosmetic medical procedures. (For such areas, refrain from use for 2 weeks after the procedure and consult a doctor before resuming use. Examples of procedures: hyaluronic acid injection, silicone injection, Botox, thread lift, double eyelid surgery, HIFU, etc.)

If you feel unwell or notice any skin abnormalities during use, stop immediately and consult a doctor if the condition does not improve.

3. Produttu Finituview è Features

The YA-MAN RF Core EX HRF-18T combines three advanced technologies for comprehensive beauty care:

  • RF (Radio Frequency): This high-frequency technology warms the skin from deep within by reacting to moisture, commonly used in professional beauty salons.
  • Cavitazione: Utilizes powerful 330kHz ultrasonic waves to vibrate the skin, targeting specific areas.
  • EMS (Stimulazione Musculare Elettrica): Delivers electrical impulses to stimulate muscles. This model features a "Double Wave EMS" combining medium and low frequencies.

This device offers total care for the face, body, and bust. It is waterproof (IPX7 equivalent), allowing for safe use during bath time to enhance the warming effect.

YA-MAN RF Core EX HRF-18T device

Image: The YA-MAN RF Core EX HRF-18T device, showcasing u so design ergonomicu è u so pannellu di cuntrollu.

YA-MAN RF Core EX HRF-18T features: RF, Cavitation, EMS

Image: Diagram illustrating the three core technologies of the device: RF for warming, Cavitation for targeted vibration, and EMS for muscle stimulation.

4. Setup

4.1 Disimballaggio è ispezione iniziale

Carefully remove the device and all accessories from the packaging. Check for any visible damage. The package should contain:

  • YA-MAN RF Core EX HRF-18T main unit
  • Adattatore AC
  • Manuale d'istruzzioni (stu documentu)

4.2 Caricà u dispusitivu

  1. Connect the AC adapter to the charging port on the device.
  2. Plug the AC adapter into a power outlet (100-240V).
  3. A luce indicatrice di carica s'illuminerà. Una carica cumpleta dura circa 3 ore.
  4. Once fully charged, the indicator light will change or turn off (refer to the device's specific indicator behavior).

Nota: Ensure the device is fully charged before its first use for optimal performance. Do not operate the device while it is charging.

YA-MAN RF Core EX HRF-18T on charging base

Image: The YA-MAN RF Core EX HRF-18T device placed on its charging base, indicating the charging process.

5. Operating Instructions

Before use, ensure your skin is moisturized with gel or lotion. The device can be used in the bath, but applying a conductive gel is recommended for smoother gliding and better results.

5.1 Accensione/Spegnimentu è Selezzione di Modu

  1. Appughjà è mantene u buttone di putenza per accende u dispusitivu.
  2. Press the "MODE" button to cycle through available modes (e.g., RF, Cavitation, EMS).
  3. Use the level adjustment buttons (usually "+" and "-") to select the desired intensity for RF (3 levels) and EMS (6 levels).
  4. Per disattivà u dispusitivu, appughjà è mantene u buttone di putenza.
YA-MAN RF Core EX HRF-18T mode and level selection

Image: Close-up of the device's control panel, showing buttons for mode selection and intensity levels for RF (3 levels) and EMS (6 levels).

5.2 Usage Areas and Techniques

The device is designed for use on various body parts, face, and bust. A typical session duration is approximately 10 minutes per area.

For Body:

  • Armi: Glide the device upwards from the elbow to the shoulder.
  • abdomen: Move the device in circular motions or upwards from the lower abdomen.
  • Hips: Glide the device upwards from the thighs towards the hips.
  • Cosce: Move the device upwards from the knee to the hip.
  • Vitelli: Glide the device upwards from the ankle to the knee.

For Face:

  • Guance : Gently glide the device upwards from the jawline towards the temples.
  • fronte : Move the device upwards from the eyebrows to the hairline.
  • Jawline: Glide along the jawline from the chin towards the ears.

For Bust (EX Model Exclusive):

The Bust Mode is specifically designed to target muscles around the bust area. This mode combines RF and EMS for a dual approach.

  1. Passu 1: Before treatment, stretch your back to refresh the area.
  2. Passu 2: Gently glide the device from under the bust towards the armpit, feeling the RF warmth and EMS stimulation.
  3. Passu 3: Move the device upwards from the back towards the bust, lifting the muscles.
YA-MAN RF Core EX HRF-18T Bust Mode

Image: Illustration detailing the exclusive Bust Mode feature of the EX model, showing the target muscles (pectoralis major and minor) and the combined RF and EMS approach.

YA-MAN RF Core EX HRF-18T usage guide for body, face, and bust

Image: Visual guide demonstrating recommended usage techniques for various body parts (arms, abdomen, hips, thighs, calves), face, and a three-step process for the Bust Mode.

Impurtante: Always apply a conductive gel or lotion to the skin before using the device to ensure smooth gliding and effective treatment. Avoid using the device on dry skin.

6. Mantenimentu

Una manutenzione adatta garantisce a longevità è l'igiene di u vostru apparechju.

6.1 Pulizia di u dispusitivu

  1. Dopu ogni usu, asciugate u dispusitivu cù un pannu dolce èamp tela.
  2. For stubborn residue, use a mild soap solution on the cloth, then wipe again with a clean, damp tela.
  3. Assicuratevi chì ùn entre micca acqua in u portu di carica o in altre aperture.
  4. Dry the device thoroughly with a soft, dry cloth before storing.

Nota: The device is waterproof, but it is important to dry it completely after use, especially if used in the bath, to prevent water accumulation in crevices and ensure proper function.

6.2 Storage

Store the device in a cool, dry place, away from direct sunlight and extreme temperatures. Keep it out of reach of children.

7. Risoluzione di prublemi

If you encounter any issues with your YA-MAN RF Core EX HRF-18T, please refer to the following common problems and solutions:

PrublemuCausa PossibileSoluzione
U dispositivu ùn accende micca.A batteria hè scaricata.Caricate u dispusitivu per circa 3 ore.
No sensation or weak sensation during use.Insufficient conductive gel/lotion.
U livellu d'intensità hè troppu bassu.
Device not making full contact with skin.
Apply more gel/lotion.
Aumentà u livellu di intensità.
Ensure the device head is in full contact with the skin.
Skin feels uncomfortable or irritated.U livellu d'intensità hè troppu altu.
A pelle hè troppu secca.
Reazione allergique.
Riduce u livellu d'intensità.
Apply more gel/lotion.
Stop use immediately and consult a doctor if irritation persists.
Charging issues (e.g., not charging, intermittent charging).Charging port or adapter connection issues.
Corroded charging terminals.
Ensure the AC adapter is securely connected to both the device and the power outlet. Clean charging terminals if visible corrosion. If issues persist, contact customer support.

If the problem persists after trying these solutions, please contact YA-MAN customer support.

8. Specificazioni

FeatureDetail
Numero di mudelluHRF-18T
MarcaJA-MAN
Input Voltage100-240 V
Dimensioni (circa)83 × 116 × 97 mm
Main Unit Weight (approx.)307 g
Paese di fabricazioneGiappone
AccessoriAdattatore AC
Tempu di carica (circa)3 ore
Tempu di funziunamentu (circa)minuti 30
Livellu impermeableEquivalente IPX7
MaterialiABS resin, PET resin, Polycarbonate
Tipu di batterieLithium-ion (custruitu)

9. Garanzia è Support

For warranty information and customer support, please refer to the warranty card included with your product or visit the official YA-MAN websitu. Conservate a vostra prova d'acquistu per e richieste di garanzia.

If you experience any issues not covered in the troubleshooting section, or require further assistance, please contact YA-MAN customer service.

YA-MAN Official Websitu: www.ya-man.com

Documenti cunnessi - HRF-18T

Preview YA-MAN Photo PLUS Hyper HRF-11 Instruction Manual
Comprehensive instruction manual for the YA-MAN Photo PLUS Hyper HRF-11 home beauty device, covering safety precautions, features, treatment modes, usage instructions, troubleshooting, and after-service information.
Preview YA-MAN HRF-10 Photo PLUS Instruction Manual - Skincare Device Guide
Comprehensive instruction manual for the YA-MAN HRF-10 Photo PLUS home beauty device, detailing RF, EMS, Ion Cleansing, LED, and Cooling treatments for optimal skincare results.
Preview YA-MAN Liftlogy SP User Manual
User manual for the YA-MAN Liftlogy SP home-care beauty device, providing instructions on usage, safety precautions, maintenance, and troubleshooting.
Preview Manuale d'usu YA-MAN Photo Plus Deep Lift YJFA1 - Dispositivu di bellezza per a cura di a casa
Manuale d'usu cumpletu per YA-MAN Photo Plus Deep Lift YJFA1, un dispositivu di bellezza per a cura di a casa chì include tecnulugie RF, EMS, Iontoforesi, LED è Micro-corrente per u trattamentu di a pelle di u visu.
Preview YA-MAN S12 PLUS Bloom WR STAR User Manual: Skincare Device Guide
Comprehensive user manual for the YA-MAN S12 PLUS Bloom WR STAR home beauty device. Learn about safety precautions, usage, maintenance, troubleshooting, and product specifications.
Preview Dispositivu di bellezza YA-MAN Liftlogy per a cura di a casa: Guida di l'usu
Una guida cumpleta nantu à cumu aduprà u dispusitivu di bellezza per a cura di a casa YA-MAN Liftlogy, chì copre e so caratteristiche, i modi è l'usu cunsigliatu per i trattamenti di u visu è di u corpu.