DMP 716

Manuale d'usu di u modulu d'espansione di uscita DMP 716

Modellu: 716

1. Introduzione

The DMP 716 Output Expansion Module is designed to extend the output capabilities of compatible DMP control panels. It provides additional programmable relays and annunciator outputs, facilitating integration with various external devices and systems. This manual provides essential information for the proper installation, operation, and maintenance of the 716 module.

2. Caratteristiche di u produttu

  • Four programmable Form C (SPDT) relays for versatile control applications.
  • Four open collector annunciator outputs for signaling and status indication.
  • Designed for seamless integration with all LX-Bus circuits, ensuring reliable communication.
  • Compact and durable design suitable for various installation environments.

3. Setup è Installazione

Before beginning installation, ensure all power to the control panel and associated devices is disconnected. Refer to the control panel's installation guide for specific wiring diagrams and power requirements.

3.1 Muntamentu

The 716 module should be mounted securely within the control panel enclosure or a suitable auxiliary enclosure. Use the provided mounting holes to fasten the module to a flat surface, ensuring adequate ventilation.

3.2 Cablu

Connect the 716 module to the control panel's LX-Bus terminals. Observe proper polarity for power connections. Connect external devices to the Form C relays and open collector annunciator outputs as required by your system design. Ensure all connections are secure and insulated.

DMP 716 Output Expansion Module with its cover removed, showing the circuit board.

This image displays the DMP 716 Output Expansion Module. The main component is a green circuit board populated with various electronic components, including relays and integrated circuits, mounted within a white plastic housing. To the right, the module's white plastic cover is shown detached, indicating the internal view di u dispusitivu.

3.3 Cunfigurazione

After physical installation, configure the 716 module's outputs through the control panel's programming interface. Refer to your control panel's programming manual for detailed instructions on assigning functions to the relays and annunciator outputs.

4. Funziunamentu di u Modulu

The DMP 716 module operates under the control of the connected DMP control panel. Its relays and annunciator outputs will activate or deactivate based on the programming and events within the security or automation system.

  • Uscite à relè: The four Form C (SPDT) relays can be programmed to switch external circuits (e.g., lights, sirens, door locks) based on system events like alarms, arming status, or specific zone conditions.
  • Annunciator Outputs: The four open collector outputs provide low-current signaling for devices such as LEDs or small buzzers, indicating system status or specific event occurrences.

Always ensure that the connected devices' power requirements do not exceed the module's output specifications.

5. Mantenimentu

The DMP 716 module is designed for reliable, long-term operation with minimal maintenance. Regular inspection is recommended to ensure optimal performance.

  • Ispezione visuale: Periodically inspect the module for any signs of physical damage, loose connections, or corrosion.
  • Pulizia: If necessary, gently clean the module's exterior with a soft, dry cloth. Do not use liquid cleaners or solvents.
  • Actualizazioni di firmware: Consult DMP technical support or your installer for information regarding any available firmware updates for your control panel that may affect module operation.

6. Risoluzione di prublemi

If you experience issues with the DMP 716 module, consider the following troubleshooting steps:

  • U modulu ùn risponde micca:
    • Verify that the LX-Bus connections are secure and correctly polarized.
    • Check the control panel's power supply.
    • Ensure the module is properly addressed or recognized by the control panel in its programming.
  • Output Not Activating:
    • Confirm the output is correctly programmed in the control panel for the desired event.
    • Check the wiring to the external device connected to the output.
    • Verify the external device is functioning correctly and its power requirements are met.
    • Ensure the load connected to the relay does not exceed its maximum current rating.
  • Operazione intermittente:
    • Inspect all wiring for loose connections or damaged insulation.
    • Check for potential electrical interference from nearby equipment.

If problems persist after attempting these steps, contact your installer or DMP technical support.

7. Specificazioni

AttributuValore
U fabricatoreDMP
Numeru di mudellu di pruduttu716
Dimensioni (L x W x H)20.32 x 15.24 x 5.08 cm
Pesu453.59 g
Uscite Relay4 x Form C (SPDT) programmable
Uscite di l'Annunciatori4 x Open Collector
Cumpatibilità di l'autobusLX-Bus

8. Garanzia è Support

For warranty information regarding your DMP 716 Output Expansion Module, please refer to the documentation provided at the time of purchase or contact your authorized DMP dealer. DMP products are typically covered by a limited warranty against defects in materials and workmanship.

For technical support, installation assistance, or advanced troubleshooting, please contact your security system installer or visit the official DMP websitu per risorse di supportu è informazioni di cuntattu.

Documenti cunnessi - 716

Preview DMP 716 Output Expansion Module Guida di Installazione
Installation guide for the DMP 716 Output Expansion Module, detailing its features, mounting, wiring, addressing, and programming for XR150/XR550 series alarm panels. Includes specifications and compliance information.
Preview Guida d'installazione di u Modulu di Espansione Zona DMP 712-8
Guida d'installazione cumpleta per u Modulu d'Espansione di Zona DMP 712-8. Amparate nantu à e so caratteristiche, a cumpatibilità cù i pannelli DMP XT30, XT50, XR150 è XR550, l'istruzzioni di cablaggio per LX-Bus è Keypad Bus, l'indirizzamentu di i moduli è e certificazioni di cunfurmità.
Preview DMP 711S Zone Expansion Module Guida di Installazione
Comprehensive installation guide for the DMP 711S Zone Expansion Module, detailing setup, wiring, programming, and compliance for DMP XT30/XT50 and XR150/XR550 series alarm panels.
Preview DMP 710 Bus Splitter/Repeater Module Installation Guide | Expand LX-Bus & Keypad Bus
Learn how to install and configure the DMP 710 Bus Splitter/Repeater Module. This guide covers mounting, wiring, and voltage drop considerations for expanding LX-Bus and Keypad Bus systems in security applications.
Preview 712-8INT Zone Expansion Module Installation Guide | DMP
Comprehensive installation guide for the DMP 712-8INT Zone Expansion Module. Learn how to mount, wire, and address the module for DMP XT30INT, XT50INT, XR150INT, and XR550INT series security panels.
Preview Guida d'installazione di u Modulu Splitter / Repeater di Bus DMP 710
Guida d'installazione per u Modulu Splitter/Ripetitore di Bus DMP 710, chì detalla u so usu cum'è splitter, ripetitore è scatula di giunzione per i circuiti LX-Bus è Keypad Bus. Include istruzioni di cablaggio, vol.tage drop measurements, and compatibility information.