Notifier ISO-X Fault Isolator Module User Manual

Model: ISO-X

1. Introduzione

The Notifier ISO-X Alarm Fault Isolator Module is designed to protect fire alarm system Signaling Line Circuits (SLC) from wire-to-wire short circuits. This module ensures that a short circuit on the SLC loop does not disable the entire loop, allowing other devices on the loop to continue functioning normally. It is an essential component for maintaining system integrity and reliability in fire detection and alarm systems.

The ISO-X module is compatible with various Notifier fire alarm control panels, including NFS-3030, AM2020, AFP1010, NFS-640, AFP-400, AFP-300, AFP-200, AFP-100, and System 5000.

2. Produttu Finituview

Notifier ISO-X Fault Isolator Module in its packaging

Figura 2.1: Fronte view of the Notifier ISO-X Fault Isolator Module in its original packaging. The module is white with the Notifier by Honeywell logo prominently displayed. The packaging indicates "ISO-X" and "417480".

daretu view of Notifier ISO-X Fault Isolator Module with wiring terminals

Figura 2.2: daretu view of the Notifier ISO-X Fault Isolator Module, showing the mounting bracket and wiring terminals. Labels for SLC1 and SLC2 connections are visible, along with model number, country of origin (Mexico), and UL/FM listings. Installation instructions are referenced.

3. Setup è Installazione

Installation of the ISO-X module should only be performed by qualified personnel in accordance with all local and national electrical codes, and the manufacturer's specific installation instructions (document 156-3624 referenced on the module itself).

  1. Disconnection d'energia: Assicuratevi chì tutta l'alimentazione à u pannellu di cuntrollu di l'allarme d'incendiu è i circuiti assuciati sia scollegata prima di inizià l'installazione.
  2. Muntamentu: Mount the ISO-X module in a suitable location, typically within an electrical enclosure or junction box, using the provided mounting holes. Ensure proper ventilation if required by local codes.
  3. cablaggio: Connect the Signaling Line Circuit (SLC) wires to the designated terminals on the module. The module supports two SLC loops (SLC1 and SLC2) with positive (+) and negative (-) terminals for each. Refer to the wiring diagram provided with the module and the fire alarm control panel for correct polarity and connection points. The module is designed for 4-wire applications.
  4. Verificazione: After wiring, visually inspect all connections to ensure they are secure and correctly terminated.
  5. Restaurazione di l'energia: Restore power to the fire alarm control panel and verify proper operation of the SLC loop and connected devices.

Note: The module is designed for indoor, dry applications only.

4. Operazione

The Notifier ISO-X module operates passively within the SLC loop. In the event of a wire-to-wire short circuit on the SLC loop, the ISO-X module automatically isolates the affected segment of the loop. This isolation prevents the short circuit from disrupting communication with other devices on the healthy segments of the loop.

Once the short circuit condition is cleared, the ISO-X module automatically restores the isolated segment to normal operation, allowing full communication across the entire SLC loop without manual intervention.

5. Mantenimentu

The Notifier ISO-X module requires minimal maintenance. Regular system inspections and testing, as mandated by local fire codes and standards (e.g., NFPA 72), will ensure the continued proper functioning of the module and the overall fire alarm system.

6. Risoluzione di prublemi

If a fault is indicated on the SLC loop, and the ISO-X module is suspected:

7. Specificazioni

AttributuValore
MarcaNotificatore
Numero di mudelluISO-X
Part NumberISO-X
UPC636836973661
Fonte d'energiaCorded Electric (SLC Loop)
CuloreBiancu
Pesu di l'articulu5.6 once
Dimensioni di u produttu6 x 6 x 2 inch
Numero di Articuli1
ApplicazioneIndoor, Dry Applications Only
CumpatibilitàNFS-3030, AM2020, AFP1010, NFS-640, AFP-400, AFP-300, AFP-200, AFP-100, System 5000

8. Garanzia è Support

For specific warranty information regarding your Notifier ISO-X module, please refer to the documentation provided with your purchase or contact Notifier directly. Warranty terms typically cover defects in materials and workmanship under normal use.

For technical support, installation assistance, or to report issues, please contact Notifier customer service or your authorized Notifier distributor. When contacting support, please have your product model number (ISO-X) and any relevant system information ready.

Informazioni di cuntattu:

Documenti cunnessi - ISO-X

Preview Notifier MMX-1(A), CMX-2(A), and ISO-X Fault Isolator Module Installation Instructions
Installation guide for Notifier MMX-1(A) Monitor Module, CMX-2(A) Control Module, and ISO-X Fault Isolator Module. Provides details on general description, compatibility, mounting, wiring, and testing procedures.
Preview Specifiche tecniche di u modulu di monitoraghju à dece ingressi Notifier XP10-M(A)
Specifiche tecniche dettagliate è caratteristiche per u Modulu di Monitoraghju à Deci Ingressi Notifier XP10-M(A), un dispositivu indirizzabile per sistemi d'allarme intelligenti.
Preview Scheda tecnica di i moduli di cuntrollu è relè di a serie Notifier FCM-1(A) è FRM-1(A)
Scheda tecnica per u Modulu di Cuntrollu Indirizzabile FCM-1(A) di Notifier è u Modulu di Relè Indirizzabile FRM-1(A), chì dettaglia e caratteristiche, l'applicazioni, e specifiche è l'approvazioni di l'agenzia per i sistemi d'allarme d'incendiu.
Preview Notifier FZM-1A Interface Module: Installation and Maintenance Instructions
Comprehensive guide for installing and maintaining the Notifier FZM-1A Interface Module. Includes detailed specifications, wiring diagrams for NFPA Class B and Class A configurations, mounting instructions, and general descriptions for fire alarm systems.
Preview Notifier NCM-1 Noise Control Module: Technical Specifications and Installation Guide
Detailed technical specifications, features, and installation guidelines for the Notifier NCM-1 Noise Control Module, designed to reduce common mode noise on Signaling Line Circuits. Includes wiring specifications for AIM-200, AM2020, and AFP1010 systems.
Preview Istruzzioni d'installazione di u modulu d'entrata/uscita di u sistema radio Notifier NRX-M711
Guida d'installazione cumpleta per u modulu d'entrata-uscita radio Notifier NRX-M711, chì detalla e so specifiche, a lista di e parti, u cablaggio, a prugrammazione è a messa in serviziu per i sistemi d'allarme incendiu.