VOLTCRAFT VLP-1602

Voltcraft VLP-1602 USB Laboratory Power Supply User Manual

Modellu: VLP-1602

1. Introduzione

This manual provides essential information for the safe and efficient operation of your Voltcraft VLP-1602 USB Laboratory Power Supply. The VLP-1602 is a versatile, adjustable power supply designed for laboratory and development applications, offering precise control over voltage è attuale.

E caratteristiche chjave includenu:

2. Informazioni di sicurezza

Leghjite è capite tutte l'istruzzioni di sicurezza prima di fà funziunà l'apparechju. A mancanza di seguitu di queste istruzzioni pò causà scossa elettrica, incendi o ferite gravi.

3. Setup

3.1 Unpacking è Inspection

Carefully remove the power supply from its packaging. Inspect the unit for any signs of damage that may have occurred during transit. If any damage is found, do not operate the device and contact your supplier.

3.2 Cunnessione à l'alimentazione

  1. Assicuratevi chì l'interruttore di alimentazione nantu à u pannellu frontale sia in a pusizione "OFF".
  2. Connect the provided power cord to the AC inlet on the rear panel of the power supply.
  3. Plug the other end of the power cord into a standard 230V AC, 50Hz grounded electrical outlet.
Rear panel of the Voltcraft VLP-1602 USB Laboratory Power Supply showing the AC inlet, fuse holder, and ventilation fins.
Figura 1: Cunnessione di u pannellu posteriore. This image displays the rear panel of the VLP-1602, highlighting the AC power input, fuse compartment, and heat sink for proper ventilation.

3.3 Accensione iniziale

After connecting the power cord, switch the power supply ON using the main power switch on the front panel. The display should illuminate, indicating the device is ready for operation.

4. Operating Instructions

4.1 Front Panel Overview

Front panel of the Voltcraft VLP-1602 USB Laboratory Power Supply with displays, control knobs, and output terminals.
Figure 2: Front Panel Controls and Displays. This image shows the main display for voltage and current, control knobs for adjustment, and the various output terminals (Output A, Output B-USB).

The front panel features digital displays for voltage and current, control knobs for precise adjustment, and multiple output terminals.

4.2 Ajustà u vulumetage and Current (Output A)

  1. Connect your load to the main output terminals (Output A). Use the red terminal for positive (+) and the black terminal for negative (-). The yellow terminal is for ground.
  2. Turn the "VOLT" knob to set the desired output voltage. The digital display will show the set voltage.
  3. Turn the "AMPERE" knob to set the desired current limit. This acts as a current limiter to protect your circuit.
  4. The "C-LIMIT" indicator will illuminate if the current limit is reached.
  5. The "OVP" (Overvoltage Protection) indicator will illuminate if an overvoltage condition occurs.
A hand adjusting a knob on the Voltcraft VLP-1602 USB Laboratory Power Supply.
Figure 3: Adjusting Output Parameters. This image illustrates the user interacting with the control knobs on the front panel to adjust voltage or current settings.

4.3 Using the USB Outputs (Output B-USB)

The VLP-1602 includes dedicated USB outputs for testing and development purposes. These outputs can be used to stress connected USB devices.

5. Mantenimentu

5.1 Pulizia

To clean the exterior of the power supply, use a soft, damp cloth. Do not use abrasive cleaners or solvents. Ensure the device is powered off and unplugged before cleaning.

5.2 Sustituzione di Fuse

If the power supply does not turn on, check the fuse located on the rear panel near the AC inlet.

  1. Scollegate u cordone di alimentazione da a presa AC.
  2. Use a flat-head screwdriver to open the fuse holder.
  3. Replace the blown fuse with a new fuse of the same type and rating (T 1.6A / 250V).
  4. Close the fuse holder securely.

Attenzione: Always replace fuses with the specified type and rating to prevent damage to the unit or risk of fire.

6. Risoluzione di prublemi

PrublemuCausa PossibileSoluzione
U dispusitivu ùn accende micca.No power from outlet, power cord disconnected, blown fuse.Check power outlet, ensure power cord is securely connected, replace fuse (see Section 5.2).
No uscita voltage/current.Output terminals not connected, voltage/current knobs set to zero, OVP/OCP triggered.Ensure load is properly connected, adjust voltage/current knobs, check for OVP/OCP indicators and reset if necessary.
Risultatu voltagA corrente e/ hè instabile.Poor connection, faulty load, internal issue.Check all connections, test with a different load. If problem persists, contact support.
Overvoltage Protection (OVP) indicator is on.Risultatu voltage exceeded a safe limit.Reduce the set voltage or check the load for issues. Power cycle the unit to reset OVP.

7. Specificazioni

ParametruValore
Numero di mudelluVLP-1602
U fabricatoreVOLTCRAFT
Uscita Voltage (principale)0 - 60 V
Output Current (Main)0.01 - 1.5 A
Numero di Outputs3 (Main + 2 USB)
Forza di output123 W
Input Voltage230 Volts
Dimensioni (L x W x H)27 x 26 x 11.5 cm
Pesu6.6 chilògrammi
Funzioni spicialiHigh-precision multi-speed potentiometer, USB development port
Tipu di cunnessuUSB

8. Garanzia è Support

8.1 Garanzia infurmazione

The Voltcraft VLP-1602 USB Laboratory Power Supply comes with a 1-year availability of spare parts. For specific warranty terms and conditions, please refer to the documentation provided with your purchase or contact your retailer.

8.2 Assistenza Clienti

For technical assistance, troubleshooting, or service inquiries, please contact Voltcraft customer support or your authorized dealer. Please have your model number (VLP-1602) and purchase information ready when contacting support.