This manual provides comprehensive instructions for the safe and effective use of your OSITO Foot Circulation Stimulator. This device utilizes Electrical Muscle Stimulation (EMS) and Transcutaneous Electrical Nerve Stimulation (TENS) technologies to support foot and leg comfort. Please read this manual thoroughly before operating the device and retain it for future reference.
Importante infurmazione di sicurezza
ATTENZIONE: To reduce the risk of electric shock, burns, fire, or injury, always follow these instructions:
Use only on dry feet.
Ùn sottumette micca u dispositivu in acqua.
Mantene luntanu da fonti di calore.
Consult a doctor before use if you have any medical conditions, especially foot injuries, nerve issues, or if you are pregnant.
Do not use if you have a pacemaker or any implanted electronic device.
Do not use on the head.
Do not use if you have Deep Vein Thrombosis (DVT).
Scollegate è lasciate chì u massaggiatore si rinfreschi prima di almacenallu.
Mantene u cordone di alimentazione luntanu da u calore è l'umidità.
Dichjarazioni riguardanti i supplementi dietetichi ùn sò micca stati valutati da a FDA è ùn sò micca destinati à diagnosticà, trattà, curà o prevene ogni malatia o cundizione di salute.
Always consult your physician before starting any new treatment, especially if you have pre-existing medical conditions.
Cumpunenti di u produttu
The OSITO Foot Circulation Stimulator package includes the following items:
OSITO Foot Circulation Stimulator Unit
Adattatore di putenza
Control remoto
Electrode TENS Pads (4 pieces)
Connecting Cables for TENS Pads
Manuale d'istruzzioni
Image: The OSITO Foot Circulation Stimulator unit, power adapter, remote control, TENS pads, and connecting cables.
Istituisci
Imballà: Eliminate cù cura tutti i cumpunenti da l'imballu.
Placement: Place the OSITO Foot Circulation Stimulator on a flat, stable surface in a comfortable area where you can sit.
Cunnessione di putenza: Plug the power adapter into the unit's power port, then plug the adapter into a standard electrical outlet.
Batterie di cuntrollu remoto: Inserite 2 batterie AAA in u telecomandu (batterie micca incluse).
Image: The OSITO Foot Circulation Stimulator placed on the floor in a home environment, ready for use.
Istruzzioni di funziunamentu
1. Basic Operation (Foot Stimulation)
Preparate i pedi: For optimal conductivity, ensure your feet are clean and dry. Some users find applying a few drops of water or using damp paper towels under their feet can enhance the sensation.
Piedi di pusizioni: Sit comfortably and place your bare feet on the foot pads of the stimulator unit.
Power On: Press u ON/OFF button on the unit or remote control to activate the device. The display will illuminate.
Selezziunà u Modu: Aduprà u SOLE MODE buttons on the unit or remote to cycle through the 25 available stimulation modes. Each mode offers a different pattern of electrical pulses.
Aghjustate l'intensità: Aduprà u SOLE + è SOLE - buttons to adjust the intensity level from 1 to 99. Start at a low intensity and gradually increase until you feel a comfortable, yet noticeable, sensation.
Durata di a Sessione: The device has a default session time, typically 25 minutes, after which it will automatically shut off.
Spegnimentu: To end a session early, press the ON/OFF buttone.
Image: A person seated with bare feet placed on the OSITO Foot Circulation Stimulator, demonstrating typical use.
2. Using TENS Pads (Body Stimulation)
The device includes TENS pads for targeted stimulation on other parts of the body. These can be used independently or simultaneously with foot stimulation.
Cunnette i cuscinetti: Plug the connecting cables into the TENS pad ports on the side of the main unit. Attach the electrode pads to the other end of the cables.
Applicà i cuscinetti: Ensure your skin is clean and dry. Stick the TENS pads firmly onto the desired area of your body (e.g., back, shoulders, legs). Avoid placing pads on sensitive areas, broken skin, or near the heart.
Power On: Press u ON/OFF buttone.
Selezziunà u Modu: Aduprà u BODY MODE buttons on the unit or remote to select a stimulation mode for the TENS pads.
Aghjustate l'intensità: Aduprà u CORPO + è BODY - buttons to adjust the intensity level for the TENS pads. Adjust to a comfortable level.
Eliminate i cuscinetti: After use, gently peel the pads off your skin. Moisten the pads with a few drops of water and place them back on their plastic film to preserve their adhesive quality.
Image: A person with TENS pads applied to their upper back, demonstrating the use of the body stimulation feature.
Imagine: Primu pianu view of the TENS pads and their connecting cables, showing how they attach to the body.
Modes and Intensity Levels
The OSITO Foot Circulation Stimulator offers 25 distinct massage modes and 99 intensity levels to customize your experience. The intensity levels are categorized for guidance:
Livelli 1-9: Soft
Livelli 10-29: Liggeru
Livelli 30-49: Cunfortu
Livelli 50-69: Medium
Livelli 70-89: Slightly Stronger
Livelli 90-99: Forte
Image: Visual representation of the 25 massage modes and 99 intensity levels, categorized by sensation.
Mantenimentu
Pulizia di l'unità: Asciugà l'unità principale cun un soffiu, damp pannu. Ùn aduprate micca detergenti abrasivi è ùn immergete micca l'unità in acqua.
Cleaning TENS Pads: After each use, moisten the TENS pads with a few drops of water and place them back on their plastic film. This helps maintain their adhesive quality and extends their lifespan.
Conservazione: Store the device in a cool, dry place, away from direct sunlight and extreme temperatures. Ensure the power cord is not kinked or damaged.
Sustituzione di batterie: Replace remote control batteries when the remote's functionality diminishes.
Risoluzione di prublemi
Prublemu
Causa Possibile
Soluzione
No sensation or weak sensation from foot pads.
I pedi sò troppu secchi.
U livellu d'intensità hè troppu bassu.
Poor contact with foot pads.
Moisten feet with a few drops of water or use damp paper towels under feet.
Increase the intensity level gradually (some users may need to start above level 20).
Ensure bare feet are fully in contact with the foot pads.
U dispusitivu ùn accende micca.
L'adattatore di corrente ùn hè micca cunnessu currettamente.
Nisuna alimentazione da a presa.
Verificate tutte e cunnessione di energia.
Pruvate à cunnette in una presa diversa.
U cuntrollu remoto ùn funziona micca.
Batterie morte.
Ostruzione trà u telecomandu è l'unità.
Rimpiazzà e batterie AAA.
Ensure a clear line of sight to the unit's sensor.
TENS pads not adhering or providing sensation.
Pads are dry or dirty.
Pads are worn out.
I cavi ùn sò micca cunnessi bè.
Moisten pads with water and ensure skin is clean.
Replace pads if they have lost their adhesive or conductivity.
Check cable connections to both the unit and the pads.
Specific warranty information for the OSITO Foot Circulation Stimulator is not provided in this manual. For warranty details, technical support, or customer service inquiries, please refer to the contact information provided with your product packaging or visit the official OSITO websitu.
You may also contact the seller directly through the platform where the product was purchased for assistance.
Documenti cunnessi - B07JM1BMB3
Manuale d'usu di u Booster di Circulazione Sanguigna OSITO: Tecnulugia TENS è EMS Manuale d'usu cumpletu per l'OSITO Circulation Blood Booster, chì detalla e so tecnulugie TENS è EMS, e caratteristiche, u funziunamentu, a manutenzione è a risoluzione di i prublemi per un sollievu efficace di u dolore è a stimulazione musculare.
Hubble the Bear: Guida d'Usuariu è Funzionalità Descubra u Hubble the Bear, u primu osito di peluche intelligente di u mondu per messageria. Sta guida cumpleta cubre a cunfigurazione, e funzioni, a sicurità è e dumande frecuenti per una sperienza cunnessa.
Catalogue de Produits Electroniques et Hogar Esplora una amplia gamma di prudutti, da l'elettronica di u cunsumu è l'elettrodomestici finu à l'articuli per a casa è l'accessori. Scuprite l'ultime novità in a tecnulugia è a casa.