The Riello MG569 BWZG is a sophisticated control unit designed for reliable and efficient operation of Riello gas burners. This unit manages the ignition, flame supervision, and safety functions of the burner, ensuring optimal performance and adherence to safety standards. It is a direct replacement for several older models, offering enhanced functionality and compatibility.

1.1 Cumpatibilità

This control unit is compatible with the following Riello burner series:

It also replaces previous control unit models including 3002949, 3002967, 569SE, 568SE, 566SE rev3, 566SE rev2, 566SE rev1, and 525SE/G.

Riello MG569 BWZG Control Unit, top view showing terminal connections

Figura 1: Top view of the Riello MG569 BWZG Control Unit, illustrating the various terminal connections for power, ignition, and burner components.

2. Setup è Installazione

Installation of the Riello MG569 BWZG control unit requires specialized knowledge of electrical systems and burner operation. It is strongly recommended that installation be performed by a qualified and certified technician to ensure safety and proper functionality.

2.1 Precauzioni di sicurezza

2.2 Passi d'installazione (generali)

  1. Eliminate a vechja unità: Carefully disconnect and remove the existing control unit, noting all wiring connections.
  2. Muntà una nova unità: Securely mount the Riello MG569 BWZG control unit in the designated position.
  3. Cunnette u cablaggio: Connect all electrical wires according to the burner's wiring diagram. This typically includes connections for power supply (L1, N), ignition transformer, flame sensor, motor, and fuel valve. Ensure all connections are tight and secure.
  4. Messa a terra: Verify that the unit and burner system are properly grounded to prevent electrical hazards.
  5. Cuntrolli iniziali: Before restoring power, double-check all connections for correctness and security.
  6. Ripristina l'energia: Carefully restore power to the burner system.
  7. Operazione di prova: Initiate a test firing sequence to ensure the burner ignites and operates correctly, and that all safety features are functioning.
Riello MG569 BWZG Control Unit, showing wiring terminals and mounting points

Figura 2: Un altru view of the Riello MG569 BWZG Control Unit, highlighting the terminal block for electrical connections and mounting screw locations.

3. Operating Instructions

The Riello MG569 BWZG control unit operates automatically once installed and powered. Its primary function is to manage the burner's ignition sequence, flame supervision, and shutdown procedures in case of malfunction.

3.1 Normal Operation Sequence

  1. Abbrivu: Upon receiving a call for heat, the control unit initiates a pre-purge cycle to clear the combustion chamber.
  2. accensione: After pre-purge, the ignition transformer is activated, creating a spark, and the fuel valve opens to allow fuel into the combustion chamber.
  3. Flame Detection: The flame sensor (e.g., photocell or ionization probe) detects the presence of a flame. If a flame is established within the safety time, the ignition spark is cut off, and the burner continues to operate.
  4. Corsa: The burner operates under the supervision of the control unit, which continuously monitors the flame.
  5. Chjodi: When the call for heat ends, the fuel valve closes, and the burner shuts down. A post-purge cycle may follow.

3.2 Indicatori luminosi

The control unit may feature indicator lights (LEDs) to signal its operational status or fault conditions. Consult your burner's specific documentation for a detailed explanation of these indicators. Typically, a steady green light indicates normal operation, while a flashing or red light signifies a fault.

4. Mantenimentu

Regular maintenance is crucial for the longevity and safe operation of your burner system and its control unit. All maintenance should be performed by a qualified service technician.

4.1 Schedule di mantenimentu cunsigliatu

Nota: The control unit itself is a sealed component and is not user-serviceable. Any internal issues require replacement of the unit.

5. Risoluzione di prublemi

This section provides general guidance for common issues. For detailed diagnostics, consult a qualified technician.

PrublemuCausa PossibileAzzione
Burner does not start / No ignition
  • No power supply to the control unit.
  • Safety lockout (fault condition).
  • Faulty ignition transformer or electrodes.
  • Nisun fornimentu di carburante.
  • Check main power switch and circuit breaker.
  • Press the reset button on the control unit (if present). If it locks out again, do not repeatedly reset.
  • Verify fuel supply valve is open.
  • Cuntattate un tecnicu qualificatu.
Burner ignites but immediately shuts down (flame failure)
  • Dirty or faulty flame sensor.
  • Aria di combustione insufficiente.
  • Bassa pressione di carburante.
  • Unità di cuntrollu difettosa.
  • Inspect and clean flame sensor (if accessible and safe).
  • Ensure air intakes are clear.
  • Contact a qualified technician for fuel pressure and control unit diagnostics.
Control unit shows a fault code/light
  • Specific fault detected by the unit.
  • Refer to your burner's specific manual for fault code interpretation.
  • Attempt a single reset. If the fault persists, contact a qualified technician.

6. Specifiche tecniche

Riello MG569 BWZG Control Unit, side view showing product label with technical specifications

Figura 3: Side view of the Riello MG569 BWZG Control Unit, displaying the product label with key technical specifications.

FeatureDetail
Numero di mudelluMG569 BWZG
U fabricatoreRiellu
Voltage210-230V ~ 50/60Hz
FuseT4A 250V~
Ignition Voltage18 kVpk
currente11 m d'arme
UPC748810822879
CumpatibilitàRiello BS1, BS2, BS3D, BS4D series burners
Rimpiazza i mudelli3002949, 3002967, 569SE, 568SE, 566SE rev3, 566SE rev2, 566SE rev1, 525SE/G

7. Garanzia infurmazione

Specific warranty terms for the Riello MG569 BWZG control unit are typically provided by the seller or manufacturer at the time of purchase. Please retain your proof of purchase for warranty claims.

Information regarding the availability of spare parts is currently unavailable. For any spare part inquiries, please contact your supplier or an authorized Riello service center.

8. Assistenza Clienti

For technical assistance, service, or further information regarding the Riello MG569 BWZG control unit, please contact:

When contacting support, please have your product model number (MG569 BWZG) and any relevant purchase details ready.

Documenti cunnessi - MG569 BWZG

Preview Manuale d'installazione di i bruciatori à oliu residenziali Riello serie 40 F3 è F5
Stu manuale furnisce struzzioni d'installazione dettagliate per i bruciatori à oliu residenziale Riello Serie 40, mudelli F3 è F5. Copre l'identificazione di i cumpunenti, a cunfigurazione, u montaggio, i cunnessione elettriche, u piazzamentu di l'ugellu è e procedure di regulazione. U manuale hè destinatu à l'applicazioni di retrofit è include dati tecnichi, specifiche è elenchi di pezzi di ricambio.
Preview Riello 40 BF Single StagManuale d'installazione è d'usu di u bruciatore à oliu
Manuale cumpletu d'installazione è d'usu per a stufa Riello 40 BF single-stagbruciatore à oliu elettronicu, chì copre e specifiche tecniche, e procedure d'installazione, i diagrammi di cablaggio, a risoluzione di i prublemi è i pezzi di ricambio.
Preview Lista di e parti è diagramma di u bruciatore à oliu Riello Gulliver RG2F
Lista dettagliata di e parti di ricambio è schema di i cumpunenti per u bruciatore à oliu leggeru Riello Gulliver RG2F (Modellu 377T1, Codice 3737770), cumpresi i numeri di parte è e descrizioni in inglese.
Preview Priročnik za namestatev, uporabo in vzdrževanje gorilnika RIELLO Gulliver RG1NR na plinsko olje
Ta dokument vsebuje podrobna navodila za namestitev, uporabo, vzdrževanje in odpravljanje napak enostopenjskega gorilnika RIELLO Gulliver RG1NR na plinsko olje, vključno s tehničnimi podatki, varnostnimi predpis odpisi in tedpisav.
Preview Istruzzioni d'installazione è di manutenzione di u bruciatore à oliu pesante Riello P 140 P/N 471 M1
Istruzzioni cumplete d'installazione, d'usu è di mantenimentu per u bruciatore à oliu pesante Riello P 140 P/N 471 M1. Copre e specifiche tecniche, i diagrammi elettrici, i sistemi di alimentazione di carburante è e procedure di regolazione.
Preview Riello 40 G10 Light Oil Burner Installation and Maintenance Manual
This document provides comprehensive installation, use, and maintenance instructions for the Riello 40 G10 light oil burner. It includes technical data, diagrams, electrical wiring schematics, and combustion adjustment procedures.