myTouchSmart 40953

myTouchSmart Push Button In-Wall Digital Countdown Timer Switch (Model 40953) User Manual

A vostra guida per l'installazione, l'operazione è a manutenzione.

1. Introduzione

The myTouchSmart In-Wall Push-Button Countdown Timer Switch (Model 40953) is designed to simplify your routine by providing convenient automation for indoor or outdoor lighting and various appliances. This timer replaces any standard single-pole light switch and offers preset countdown times to automatically turn off connected devices. It is compatible with LED, CFL, incandescent, and halogen bulbs.

myTouchSmart Push Button Countdown Timer Switch packaging

The product packaging displays the in-wall digital countdown timer switch, highlighting its key features such as preset countdown times and compatibility with various bulb types.

2. Informazioni di sicurezza

Before beginning installation, read all instructions carefully. Improper installation can result in electrical shock or fire. Always consult a qualified electrician if you are unsure about any part of the installation process.

  • OFF POWER at the circuit breaker or fuse box before wiring.
  • Stu dispusitivu hè destinatu à a stallazione in cunfurmità cù u Codice Elettricu Naziunale è i regulamenti lucali.
  • Aduprate solu filu di cobre.
  • NEUTRAL WIRE REQUIRED per u funziunamentu.

3. Installazione

3.1 Strumenti necessarii

  • Cacciavite (Phillips è Flathead)
  • Spelafili
  • Cinta elettrica
  • Voltage Tester (recommended)

3.2 Istruzzioni di cablaggio

  1. Spegni u putere to the switch location at the circuit breaker or fuse box. Verify power is off using a voltagè testatore.
  2. Remove the existing wall plate and switch from the wall box.
  3. Carefully disconnect the wires from the old switch. Identify and label the LINE (hot), LOAD, NEUTRAL, and GROUND wires. The timer requires a neutral wire for proper operation.
  4. Connect the wires to the myTouchSmart timer using the screw terminals:
    • Cunnette u LINEA (hot) wire to the terminal labeled 'LINE'.
    • Cunnette u LOAD wire (to the light/appliance) to the terminal labeled 'LOAD'.
    • Cunnette u NEUTRE wire (typically white) to the terminal labeled 'NEUTRAL'.
    • Cunnette u TERRA wire (typically bare copper or green) to the terminal labeled 'GROUND'.
  5. Assicuratevi chì tutte e cunnessione di i fili sò sicuri.
  6. Carefully push the wired timer into the wall box.
  7. Mount the timer to the wall box using the provided screws.
  8. Attach the desired color faceplate (White or Light Almond included, wallplate not included).
  9. Ripristina u putere à u circuit breaker.
Torna view of myTouchSmart Timer showing wiring terminals

A parte posteriore view of the timer, displaying the screw terminals for Line, Load, Neutral, and Ground connections, essential for proper installation.

Latu view of myTouchSmart Timer installed in a wall box

Un prufessiunale lateralefile of the timer, showing its depth and how it fits into a standard electrical wall box, with wiring connections visible.

4. Operating Instructions

The myTouchSmart timer features an ON/OFF door panel that conceals preset buttons and LEDs when closed. Opening the door provides access to all countdown options.

4.1 Activating a Countdown

  1. Open the front door panel to reveal the preset buttons.
  2. Press the desired countdown button: 5 Min, 10 Min, 30 Min, 60 Min, 2 Hour, or 4 ore.
  3. A blue LED indicator light next to the selected button will illuminate, confirming the countdown is active. The connected device will turn on and remain on for the selected duration, then automatically turn off.
myTouchSmart Timer with door open revealing preset buttons

Un primu pianu view of the timer with its front door panel open, exposing the six preset countdown buttons (5, 10, 30, 60 minutes, 2, and 4 hours) and the manual ON/OFF button.

myTouchSmart Timer with door open and blue LED indicator

The in-wall timer with its door open, showing the preset buttons and a blue LED illuminated next to the '30 Min' button, indicating an active countdown.

Hand pressing a preset button on the myTouchSmart Timer

A hand pressing one of the preset countdown buttons on the timer, demonstrating user interaction.

4.2 Manual ON/OFF Override

  • To manually turn the connected device ON or OFF at any time, press the large ON/OFF button located at the bottom of the timer (this button is also the door panel when closed).
  • Pressing this button will override any active countdown. If no countdown is active, it functions as a standard ON/OFF switch.

4.3 Applicazioni

This timer is suitable for a variety of applications, including:

  • Illuminazione interna è esterna
  • Ventilatori di scarico
  • Riscaldatori
  • Other compatible appliances
Examples of myTouchSmart Timer applications: lights, fans, exhaust fans

An image illustrating various applications for the timer, including controlling indoor/outdoor lights, ceiling fans, and exhaust fans.

5. Mantenimentu

The myTouchSmart timer requires minimal maintenance. Follow these guidelines:

  • Pulizia: Disconnect power at the circuit breaker before cleaning. Wipe the surface with a soft, damp tela. Ùn aduprate micca chimichi duri o detergenti abrasivi.
  • Ispezione: Periodically check for any loose connections or damage to the switch. If any damage is observed, discontinue use and consult a qualified electrician.

6. Risoluzione di prublemi

If you experience issues with your myTouchSmart timer, refer to the following common problems and solutions:

PrublemuCausa PossibileSoluzione
Timer does not turn on/off.No power to the switch; Incorrect wiring (Line/Load reversed); Loose connections.Check circuit breaker. Verify wiring connections (Line to Line, Load to Load, Neutral, Ground). Ensure all wires are securely fastened.
Countdown does not activate.Button not fully pressed; Faulty unit.Ensure the desired countdown button is pressed firmly until the blue LED illuminates. If issue persists, contact customer support.
L'indicatori LED ùn funzionanu micca.No power; Unit malfunction.Check power supply. If the timer functions but LEDs do not, contact customer support.
Operazione intermittente.Loose wiring; Overload.Check all wiring connections for tightness. Ensure the connected load does not exceed the timer's electrical ratings.

Sè i passi di risoluzione di i prublemi ùn risolvenu micca u prublema, cuntattate l'assistenza clienti.

7. Specificazioni

FeatureSpecificazione
Numero di mudellu40953
Modu di funziunamentuAutomatically, Off, Push Button
Valutazione attuale15 Amps
Voltage120 VCA, 60 Hz
Carica resistiva15A
Carica di tungstenu1200 W
Valutazione di u Motore1 / 2 HP
Bulbi compatiblesLED, CFL, Incandescent, Halogen
Tipu di muntaturaMuntu à u muru
Dimensioni (L x W x H)2.75 x 4.85 x 6.85 inch
Pesu di l'articulu5.9 once
Filu neutruUbligatoriu
Cumpunenti inclusiIn-Wall Timer, White/Light Almond Door Panels

8. Garanzia è Support

Per infurmazioni nantu à a garanzia è l'assistenza tecnica, vi pregu di cunsultà u situ ufficiale di u fabricatore. websitu o cuntattate u so serviziu clienti. Cunservate a vostra ricevuta d'acquistu cum'è prova d'acquistu.

Produttore: myTouchSmart

UPC: 030878409537

Websitu: www.mytouchsmart.com (Per piacè verificate l'ufficiale) website for the most current support information.)