Strumenti Apera AI1107

Manuale d'usu di a soluzione tampone di calibrazione Apera Instruments pH 4.00

Product Overview

The Apera Instruments pH 4.00 Calibration Buffer Solution is a high-quality standard designed for accurate pH meter calibration. This 16 oz. bottle contains a solution traceable to NIST Standard Reference Materials (SRMs), ensuring reliability and precision in your measurements.

E caratteristiche chjave includenu:

  • Precisione: Reported values are accurate to +/- 0.01 pH at 25 °C.
  • Quality Manufacturing: Produced in an ISO 9001:2015 certified facility using high-purity reagents, deionized water, and certified analytical balances in a temperature-controlled environment.
  • Identificazione: Color-coded for quick and easy identification.
  • Durata di conservazione: Double-sealed with a 2-year expiration from manufacture for an unopened bottle.

Setup è Preparazione

Before using the pH 4.00 calibration buffer solution, ensure your workspace is clean and free from contaminants. Follow these steps for optimal preparation:

  1. Ispettate a buttiglia: Verify the bottle is sealed and undamaged upon receipt. The solution is double-sealed for protection.
  2. Data di scadenza di u cuntrollu: Locate the expiration date on the bottle label. Do not use the solution past its expiration date.
  3. Temperature Acclimation: Allow the buffer solution to reach the ambient temperature of your calibration environment before use. This is crucial for accurate calibration, as pH values are temperature-dependent.
  4. Gentle Mixing: Gently invert the bottle a few times to ensure homogeneity before opening. Avoid vigorous shaking, which can introduce air bubbles.
Fronte view of Apera Instruments pH 4.00 Calibration Buffer Solution bottle

Image 1: Front view of the Apera Instruments pH 4.00 Calibration Buffer Solution bottle, showing the label with product name, pH value, and volume.

Operating Instructions (Calibration Procedure)

This pH 4.00 buffer solution is used to calibrate pH meters. Always refer to your specific pH meter's instruction manual for detailed calibration steps. General steps for using this buffer are:

  1. Risciacquà l'elettrodu: Before immersing the electrode in the buffer solution, rinse it thoroughly with distilled or deionized water.
  2. Immersione di l'elettrodu: Submerge the pH electrode into a sufficient amount of pH 4.00 buffer solution. Ensure the electrode's sensing bulb and reference junction are fully immersed.
  3. Stabilizà a lettura: Allow the pH meter reading to stabilize. This may take a few moments.
  4. Perform Calibration: Initiate the calibration process on your pH meter according to its specific instructions for a 2-point or 3-point calibration, typically starting with pH 7.00, then pH 4.00, and optionally pH 10.00.
  5. Risciacquare dopu l'usu: After calibration with pH 4.00, rinse the electrode again with distilled or deionized water before proceeding to another buffer or sample.
Torna view of Apera Instruments pH 4.00 Calibration Buffer Solution bottle with pH/Temperature Reference Chart

Imagine 2: Indietro view of the Apera Instruments pH 4.00 Calibration Buffer Solution bottle, displaying a pH/Temperature Reference Chart. This chart shows the precise pH value of the solution at various temperatures, which is critical for accurate calibration.

Mantenimentu è Storage

Proper maintenance and storage are essential to preserve the accuracy and shelf life of your pH 4.00 buffer solution:

  • Température de conservation : Store the bottle at room temperature, away from direct sunlight and extreme temperature fluctuations.
  • Keep Tightly Closed: Always recap the bottle tightly immediately after use to prevent evaporation and contamination.
  • Evità a contaminazione: Never return used buffer solution to the original bottle. Pour out only the amount needed for calibration into a separate, clean beaker. Dispose of any unused portion from the beaker.
  • Durata di conservazione: The solution has a 2-year expiration from the date of manufacture when unopened. Once opened, its shelf life may be reduced depending on storage conditions and contamination.
Top view of Apera Instruments pH 4.00 Calibration Buffer Solution bottle showing the sealed cap

Imagine 3: In cima view of the Apera Instruments pH 4.00 Calibration Buffer Solution bottle, highlighting the double-sealed cap for product integrity and protection.

Risoluzione di prublemi

If you encounter issues with your pH meter calibration using this buffer solution, consider the following:

  • Incorrect pH Reading: Ensure the buffer solution is at the same temperature as your pH meter's temperature compensation setting or the sample. Refer to the pH/Temperature Reference Chart on the bottle for accurate values at different temperatures.
  • Expired Solution: Check the expiration date. Expired buffer solutions can lead to inaccurate calibrations.
  • Cuntaminazione: Verify that the buffer solution has not been contaminated by returning used solution to the bottle or by using unclean beakers/electrodes.
  • Electrode Issues: If problems persist, the issue might be with the pH electrode itself (e.g., dirty, dry, or aged). Refer to your pH meter's manual for electrode maintenance and troubleshooting.

Specificazioni

AttributuDetail
Nome di u produttupH 4.00 Calibration Buffer Solution
MarcaApera Instruments
Numero di mudelluAI1107
Volume16 oz. (approximately 473 mL)
pH Value at 25°C4.00 +/- 0.01
TracciabilitàNIST Standard Reference Materials (SRMs)
Standard di fabricazioneISO 9001:2015 certified facility with ISO 17025:2017 accreditation
FormaLiquidu
Dimensioni di u pacchettu7.87 x 2.44 x 2.4 inch
Pesu di l'articulu1.17 liri
UPC810214030201

Supportu è Risorse

For additional support, documentation, or inquiries, please refer to the following resources:

  • MSDS Documents: Material Safety Data Sheets (MSDS) are available for download to provide detailed information on the product's properties and safety precautions.
  • Certificate of Analysis: A Certificate of Analysis can be obtained upon request, verifying the quality and specifications of your specific batch.
  • U fabricatore Websitu: Visit the official Apera Instruments website for comprehensive product information, FAQs, and contact details. www.apera.com
  • Amazon Store: Explore other Apera Instruments products and resources on their Amazon store page. Apera Instruments Amazon Store

Note: This product is from a small business brand. Your support is appreciated.

Documenti cunnessi - AI1107

Preview Scheda di dati di sicurezza di a soluzione tampone APERA Instruments pH 4.00
Scheda di Dati di Sicurezza (SDS) per a Soluzione Tampone APERA Instruments pH 4.00, chì furnisce informazioni essenziali nantu à l'identificazione, i periculi, i primi aiuti, a manipulazione, u almacenamentu è a conformità normativa.
Preview Manuale d'usu di u misuratore di pH intelligente PH60Z-HT - Apera Instruments
Manuale d'usu per u pH-metru intelligente Apera Instruments PH60Z-HT, chì detalla e so caratteristiche, u funziunamentu, a calibrazione, a manutenzione è a risoluzione di i prublemi per e soluzioni caustiche è à alta temperatura.
Preview Tester di conducibilità tascabile Apera EC20: Manuale d'istruzzioni è guida
Manuale d'istruzzioni cumpletu per u tester di conducibilità tascabile Apera EC20. Amparate nantu à a cunfigurazione, a calibrazione, a misurazione di a conducibilità, e specifiche tecniche è l'infurmazioni di garanzia.
Preview Misuratore di pH portatile Apera SX811-SS per analisi alimentari: Manuale d'istruzzioni è specifiche
Manuale d'istruzzioni cumpletu è specifiche tecniche per u pH-metru portatile Apera SX811-SS, cuncipitu per analisi alimentari precise. Amparate nantu à e caratteristiche, a calibrazione, a cunfigurazione, a cumunicazione USB è a risoluzione di i prublemi.
Preview Manuale d'usu di u kit di misurazione di u pH Apera Instruments PH1 Value
Manuale d'usu per u kit di test di pH Apera Instruments PH1 Value. Fornisce struzzioni dettagliate nantu à a cunfigurazione, a calibrazione, a misurazione, l'impostazioni di i parametri, e specifiche tecniche, a cura di a sonda, a risoluzione di i prublemi, a sustituzione di a batteria è l'infurmazioni di garanzia.
Preview Apera Instruments Water Hardness Calibration Solution B1, B2, B3 Safety Data Sheet (SDS)
Safety Data Sheet (SDS) for Apera Instruments Water Hardness Calibration Solution B1, B2, B3, providing comprehensive information on identification, hazards, composition, first aid, firefighting, accidental release measures, handling, storage, exposure controls, physical and chemical properties, stability, reactivity, toxicological information, ecological information, disposal considerations, transport information, and regulatory information.