The Apera Instruments pH 4.00 Calibration Buffer Solution is a high-quality standard designed for accurate pH meter calibration. This 16 oz. bottle contains a solution traceable to NIST Standard Reference Materials (SRMs), ensuring reliability and precision in your measurements.
E caratteristiche chjave includenu:
- Precisione: Reported values are accurate to +/- 0.01 pH at 25 °C.
- Quality Manufacturing: Produced in an ISO 9001:2015 certified facility using high-purity reagents, deionized water, and certified analytical balances in a temperature-controlled environment.
- Identificazione: Color-coded for quick and easy identification.
- Durata di conservazione: Double-sealed with a 2-year expiration from manufacture for an unopened bottle.
Setup è Preparazione
Before using the pH 4.00 calibration buffer solution, ensure your workspace is clean and free from contaminants. Follow these steps for optimal preparation:
- Ispettate a buttiglia: Verify the bottle is sealed and undamaged upon receipt. The solution is double-sealed for protection.
- Data di scadenza di u cuntrollu: Locate the expiration date on the bottle label. Do not use the solution past its expiration date.
- Temperature Acclimation: Allow the buffer solution to reach the ambient temperature of your calibration environment before use. This is crucial for accurate calibration, as pH values are temperature-dependent.
- Gentle Mixing: Gently invert the bottle a few times to ensure homogeneity before opening. Avoid vigorous shaking, which can introduce air bubbles.

Image 1: Front view of the Apera Instruments pH 4.00 Calibration Buffer Solution bottle, showing the label with product name, pH value, and volume.
Operating Instructions (Calibration Procedure)
This pH 4.00 buffer solution is used to calibrate pH meters. Always refer to your specific pH meter's instruction manual for detailed calibration steps. General steps for using this buffer are:
- Risciacquà l'elettrodu: Before immersing the electrode in the buffer solution, rinse it thoroughly with distilled or deionized water.
- Immersione di l'elettrodu: Submerge the pH electrode into a sufficient amount of pH 4.00 buffer solution. Ensure the electrode's sensing bulb and reference junction are fully immersed.
- Stabilizà a lettura: Allow the pH meter reading to stabilize. This may take a few moments.
- Perform Calibration: Initiate the calibration process on your pH meter according to its specific instructions for a 2-point or 3-point calibration, typically starting with pH 7.00, then pH 4.00, and optionally pH 10.00.
- Risciacquare dopu l'usu: After calibration with pH 4.00, rinse the electrode again with distilled or deionized water before proceeding to another buffer or sample.

Imagine 2: Indietro view of the Apera Instruments pH 4.00 Calibration Buffer Solution bottle, displaying a pH/Temperature Reference Chart. This chart shows the precise pH value of the solution at various temperatures, which is critical for accurate calibration.
Mantenimentu è Storage
Proper maintenance and storage are essential to preserve the accuracy and shelf life of your pH 4.00 buffer solution:
- Température de conservation : Store the bottle at room temperature, away from direct sunlight and extreme temperature fluctuations.
- Keep Tightly Closed: Always recap the bottle tightly immediately after use to prevent evaporation and contamination.
- Evità a contaminazione: Never return used buffer solution to the original bottle. Pour out only the amount needed for calibration into a separate, clean beaker. Dispose of any unused portion from the beaker.
- Durata di conservazione: The solution has a 2-year expiration from the date of manufacture when unopened. Once opened, its shelf life may be reduced depending on storage conditions and contamination.

Imagine 3: In cima view of the Apera Instruments pH 4.00 Calibration Buffer Solution bottle, highlighting the double-sealed cap for product integrity and protection.
Risoluzione di prublemi
If you encounter issues with your pH meter calibration using this buffer solution, consider the following:
- Incorrect pH Reading: Ensure the buffer solution is at the same temperature as your pH meter's temperature compensation setting or the sample. Refer to the pH/Temperature Reference Chart on the bottle for accurate values at different temperatures.
- Expired Solution: Check the expiration date. Expired buffer solutions can lead to inaccurate calibrations.
- Cuntaminazione: Verify that the buffer solution has not been contaminated by returning used solution to the bottle or by using unclean beakers/electrodes.
- Electrode Issues: If problems persist, the issue might be with the pH electrode itself (e.g., dirty, dry, or aged). Refer to your pH meter's manual for electrode maintenance and troubleshooting.
Specificazioni
| Attributu | Detail |
|---|---|
| Nome di u produttu | pH 4.00 Calibration Buffer Solution |
| Marca | Apera Instruments |
| Numero di mudellu | AI1107 |
| Volume | 16 oz. (approximately 473 mL) |
| pH Value at 25°C | 4.00 +/- 0.01 |
| Tracciabilità | NIST Standard Reference Materials (SRMs) |
| Standard di fabricazione | ISO 9001:2015 certified facility with ISO 17025:2017 accreditation |
| Forma | Liquidu |
| Dimensioni di u pacchettu | 7.87 x 2.44 x 2.4 inch |
| Pesu di l'articulu | 1.17 liri |
| UPC | 810214030201 |
Supportu è Risorse
For additional support, documentation, or inquiries, please refer to the following resources:
- MSDS Documents: Material Safety Data Sheets (MSDS) are available for download to provide detailed information on the product's properties and safety precautions.
- Certificate of Analysis: A Certificate of Analysis can be obtained upon request, verifying the quality and specifications of your specific batch.
- U fabricatore Websitu: Visit the official Apera Instruments website for comprehensive product information, FAQs, and contact details. www.apera.com
- Amazon Store: Explore other Apera Instruments products and resources on their Amazon store page. Apera Instruments Amazon Store
Note: This product is from a small business brand. Your support is appreciated.