Introduzione
The Traceable Excursion-Trac Data Logger Thermometer is designed for precise temperature monitoring and data recording. This device simultaneously displays current, minimum, and maximum temperatures, and features a rolling memory for extensive data storage. It is equipped with a submersible probe and offers customizable alarm functions to ensure critical temperature conditions are maintained and recorded.

Image: The Traceable Excursion-Trac Data Logger Thermometer, showing its digital display and connected bullet probe.
Cuntenutu di u pacchettu
Verificate chì tutti l'articuli sò presenti à u mumentu di u disimballaggio:
- Traceable Excursion-Trac Data Logger Thermometer Unit
- Bullet Probe with 10-ft (3-m) Cable
- Unità flash USB
- Flip-Open Stand
- Hook-and-Loop Strips
- Magnetic Strips
- Wall-Mount Receptacle
- Batterie (preinstallate o separate)
- NIST-Traceable Calibration Certificate with Data
Istituisci
- Installazione di batterie: If batteries are not pre-installed, open the battery compartment on the back of the unit and insert the specified batteries, observing correct polarity.
- Cunnessione di a sonda: Connect the bullet probe cable to the designated port on the thermometer unit. Ensure a secure connection.
- Placement iniziale: Position the thermometer unit using the flip-open stand for a benchtop, or utilize the hook-and-loop strips, magnetic strips, or wall-mount receptacle for secure placement. The 10-ft (3-m) submersible micro-cable allows the probe to be placed in the desired monitoring location, even permitting doors to close over the cable.
- Power On: Press the power button (if available) or ensure the unit is active. The display should illuminate, showing current temperature readings.
Istruzzioni di funziunamentu
Operazione basica
- Display: The LCD simultaneously shows the current temperature, minimum recorded temperature (MIN), and maximum recorded temperature (MAX).
- Unità: Use the 'UNITS' button to toggle between Celsius (°C) and Fahrenheit (°F) temperature scales.
- Memoria View: The 'MEM VIEW' function allows review di dati almacenati.
Logging di dati
- The device features rolling memory, capable of retaining the most recent 525,600 temperature observations.
- Trasferimentu di dati: To transfer recorded data, insert the provided USB flash drive into the unit's USB port. The data will be saved as a CSV file, accessible on any computer without special software.
- Clear Memory: After downloading data and alarm events, the memory can be cleared to continue recording new data. Refer to the device's specific buttons (e.g., 'CLEAR') for this function.
Funzioni di alarme
- The thermometer allows setting limits for and storing up to 10 unique alarm events.
- Impostazione di l'allarmi: Use the 'ALARM' and 'SELECT/ADVANCE' buttons to set desired high and low temperature alarm thresholds.
- Smart-Alarm Function: The Smart-Alarm provides both visual and audible alerts. It continues to alert even if conditions return to the normal temperature range, ensuring that any excursion is noted.
- Silence Alarm: An 'ALARM SILENCE' button is available to temporarily mute audible alerts.
Mantenimentu
- Pulizia: Pulisci l'unità cù publicitàamp cloth. Do not submerge the main unit in water. The bullet probe is submersible and can be cleaned as needed.
- Sustituzione di batterie: When the battery indicator appears or the unit fails to power on, replace the batteries. Refer to the battery compartment for the correct battery type.
- Cura di a sonda: Handle the probe and its cable with care to prevent damage. Avoid sharp bends or excessive pulling on the cable.
Risoluzione di prublemi
| Issue | Causa Possibile | Soluzione |
|---|---|---|
| Unit does not power on or display is blank. | Batterie morte o mal installate. | Rimpiazzà e batterie, assicurendu a polarità curretta. |
| Lettura di temperatura imprecisa. | Probe not properly connected or damaged. | Ensure probe is securely connected. Inspect probe and cable for visible damage. |
| Data not transferring to USB drive. | USB drive not properly inserted or full. | Re-insert USB drive. Ensure the drive has sufficient space. Try a different USB drive if available. |
| Alarm not sounding or not clearing. | Alarm settings incorrect or alarm silenced. | Verify alarm thresholds. Check if the alarm has been manually silenced. |
Specificazioni
| Feature | Detail |
|---|---|
| Numero di mudellu | Excursion-Trac |
| Gamma di temperatura | –58 to 158 Degrees Fahrenheit (-50 to 70 Degrees Celsius) |
| Risoluzione | 0.01 gradi |
| Accuratezza | 0.25 gradi Celsius |
| Capacità di Logging di Dati | 525,600 temperature observations (rolling memory) |
| Connettività | USB (for CSV data transfer) |
| Tipu di visualizazione | LCD |
| Funzione speciale | Alarm (Smart-Alarm function) |
| Tipu di sonda | Bullet Probe, Submersible, 10-ft (3-m) cable |
| Materiale | Plastica |
| Cura di u pruduttu | Pulisci Pulì |
| Certificazione | Calibrazione tracciabile NIST |
Assistenza è Garanzia
For technical assistance, product inquiries, or warranty information, please contact the manufacturer, Cole-Parmer, or visit their official website. Specific warranty details were not provided in the product data.
Produttore: COLE-PARMER
Marca: TRACABLE
Supportu in ligna: www.coleparmer.com