TURCK C10-A10X/012VDC

TURCK C10-A10X/012VDC SPDT Relay

Guida di installazione è funziunamentu

1. Introduzione

This manual provides essential information for the safe and efficient installation, operation, and maintenance of the TURCK C10-A10X/012VDC SPDT Relay. This electromechanical relay is designed for general purpose applications, featuring a single pole double throw (SPDT) contact configuration, a 12VDC coil, and an integrated LED indicator for status monitoring. Please read this guide thoroughly before proceeding with any installation or operation.

2. Informazioni di sicurezza

Osservate sempre e seguenti precauzioni di sicurezza per prevene ferite persunali o danni à l'attrezzatura:

  • Periculu elettricu: Ensure all power sources are disconnected before installation, wiring, or maintenance. Only qualified personnel should perform electrical work.
  • Voltage e valutazioni attuali: Do not exceed the specified coil voltage (12VDC) or contact current rating (10 Amps). Overloading can cause damage or fire.
  • Cablaggio propiu: Use appropriate wire gauges and insulation for the intended current and voltage. Ensure all connections are secure to prevent arcing or short circuits.
  • Cundizioni Ambientali: Install the relay in an environment free from excessive moisture, dust, corrosive gases, or extreme temperatures.

3. Produttu Finituview

The TURCK C10-A10X/012VDC is a compact general-purpose relay designed for reliable switching in various industrial and control applications. It features a single pole double throw (SPDT) contact arrangement, allowing it to switch one circuit between two different paths. An integrated LED indicator provides visual confirmation of the coil's energized state.

TURCK C10-A10X/012VDC SPDT Relay with LED indicator

Image 1: Front view of the TURCK C10-A10X/012VDC SPDT Relay. This image displays the compact form factor of the relay, highlighting its terminal pins and the visible LED indicator on the top surface, which illuminates when the coil is energized.

4. Setup è Installazione

Segui questi passi per una stallazione curretta:

  1. Disconnection d'energia: Ensure all power to the circuit where the relay will be installed is completely disconnected and locked out.
  2. Muntamentu: Mount the relay securely in a suitable relay socket or directly onto a PCB, ensuring proper pin alignment. Refer to the relay's datasheet for specific pinout diagrams if direct soldering is required.
  3. Coil Wiring (12VDC):
    • Connect the 12VDC control voltage to the relay coil terminals. Observe polarity if specified, though many DC coils are non-polarized.
    • The LED indicator will illuminate when the 12VDC is applied across the coil terminals, indicating the coil is energized.
  4. Contact Wiring (SPDT):
    • Identify the Common (COM), Normally Open (NO), and Normally Closed (NC) contact terminals.
    • Connect the load's power source to the Common (COM) terminal.
    • Connect the load to either the Normally Open (NO) or Normally Closed (NC) terminal, depending on the desired switching behavior.
    • U volume massimu di commutazionetage is 12 Volts, and the maximum current is 10 Amps. Do not exceed these ratings.
  5. Verificazione: After wiring, double-check all connections for correctness and security before restoring power.

5. Operating Instructions

The TURCK C10-A10X/012VDC relay operates automatically based on the presence or absence of the 12VDC coil voltage.

  • Statu disenergizatu: Quandu ùn voltage is applied to the 12VDC coil, the relay is in its default state. The Common (COM) contact is connected to the Normally Closed (NC) contact. The LED indicator will be off.
  • Statu energizatu: When 12VDC is applied to the coil terminals, the coil energizes, causing the internal armature to move. The Common (COM) contact switches from the Normally Closed (NC) position to the Normally Open (NO) position. The LED indicator will illuminate, confirming the coil is energized and the contacts have switched.
  • Funzionamentu automaticu: The relay will maintain its energized state as long as the 12VDC coil voltage is present. Upon removal of the 12VDC, the relay will return to its de-energized state, and the contacts will revert to their default positions.

6. Mantenimentu

The TURCK C10-A10X/012VDC relay is designed for long-term, reliable operation with minimal maintenance. However, periodic inspection is recommended:

  • Ispezione visuale: Periodically inspect the relay and its connections for any signs of damage, discoloration, loose wires, or excessive dust accumulation.
  • Pulizia: Sè necessariu, pulite delicatamente l'esternu di u relè cù un pannu asciuttu è dolce. Ùn aduprate micca solventi o detergenti abrasivi.
  • Integrità di cunnessione: Ensure all terminal connections remain tight and secure.
  • Cuntrolla ambientale: Verify that the operating environment continues to meet the specified conditions.

7. Risoluzione di prublemi

If the relay does not function as expected, consider the following:

Prublemu Causa Possibile Soluzione
LED indicator off, contacts not switching when 12VDC applied. No 12VDC power to coil; incorrect wiring; faulty coil. Check 12VDC supply; verify coil wiring; test coil resistance (if possible) or replace relay.
LED indicator on, but load not switching. Incorrect contact wiring; open circuit in load; faulty contacts. Verify COM, NO, NC wiring; check load continuity; replace relay if contacts are faulty.
Relay humming or chattering. Insufficient coil voltage; AC voltage applied to DC coil; mechanical obstruction. Ensure stable 12VDC supply; verify DC source; inspect for physical damage or debris.
Contacts welded or stuck. Overcurrent; switching inductive loads without suppression; end of life. Ensure load current is within 10A rating; add snubber/diode for inductive loads; replace relay.

8. Specificazioni

Specificazione Valore
Marca TURCU
Numero di mudellu C10-A10X/012VDC
Tipu di cuntattu SPDT (Singulare Polu Doppiu Lanciu)
Coil Voltage 12 VDC
Current Rating (Contacts) 10 Amps
Maximum Switching Voltage 12 Volts
Modu di funziunamentu autumàticu
Indicatore LED
U fabricatore TURCU
UPC 091128524417
ASIN B088GVSC9Y
Data Prima Disponibile 11 di maghju di u 2020

9. Garanzia è Support

For information regarding product warranty, technical support, or service, please contact TURCK directly or refer to their official websitu. Mantene a vostra ricevuta di compra per i rivendicazioni di garanzia.

TURCK Official Websitu: www.turck.com

Documenti cunnessi - C10-A10X/012VDC

Preview TURCK TBEC-LL-4RFID-8DXP RFID Interface: Instructions for Use
This document provides comprehensive instructions for the TURCK TBEC-LL-4RFID-8DXP RFID Interface, detailing its installation, connection, operation, and safety guidelines for industrial automation applications.
Preview Modulu Maestru IO-Link TURCK FEN20-4IOL: Istruzzioni per l'usu
Istruzzioni cumplete per u Modulu Maestru IO-Link TURCK FEN20-4IOL, chì coprenu e so caratteristiche, l'architettura di u sistema, l'installazione, a messa in serviziu è u funziunamentu per l'applicazioni di automatizazione industriale.
Preview Guida di avviamentu rapidu di u trasduttore isolante TURCK IM33-14EX-CDRI
Stu documentu furnisce una guida di partenza rapida per u trasduttore isolante TURCK IM33-14EX-CDRI, chì copre u so usu previstu, l'istruzzioni di sicurezza, a descrizzione di u produttu, l'installazione, a messa in serviziu, u funziunamentu è a parametrizazione.
Preview TURCK NIC...-EM30-IOL-... Inductive Couplers Quick Start Guide
Quick start guide for TURCK NIC...-EM30-IOL-... inductive couplers, detailing intended use, safety precautions, product features, installation, connection, operation, LED indicators, troubleshooting, and technical specifications. Includes information on IO-Link and SIO modes.
Preview Modulu I/O di u bloccu di sicurezza TBPN-L5-4FDI-4FDX: Istruzzioni per l'usu
Stu documentu furnisce struzzioni per l'usu di u Modulu I/O di Bloccu di Sicurezza TURCK TBPN-L5-4FDI-4FDX. Copre a descrizzione di u produttu, l'infurmazioni di sicurezza, l'installazione, a cunfigurazione, u funziunamentu è i dati tecnichi per l'applicazioni di automatizazione industriale.
Preview Modulu I/O di u bloccu di sicurezza TBIP-L...-4FDI-4FDX - Istruzioni per l'usu
Stu documentu furnisce struzzioni per u Modulu I/O di Bloccu di Sicurezza TURCK TBIP-L...-4FDI-4FDX. Copre l'identificazione di u produttu, e linee guida di sicurezza, l'usu previstu, e specifiche tecniche, u montaggio, a cunnessione, a cunfigurazione è u funziunamentu.