Sartorius YSH34

Sartorius YSH34 Filter Holder Instruction Manual

For Cubis II Ultra-Micro and Micro Balances, 50 mm Diameter

1. Introduzione

This manual provides essential instructions for the proper installation, operation, and maintenance of the Sartorius YSH34 Filter Holder. This accessory is specifically designed to enhance the functionality of Sartorius Cubis II Ultra-Micro and Micro Balances, enabling precise weighing of filters up to 50 mm in diameter. Adhering to these guidelines will ensure optimal performance and longevity of your equipment.

2. Produttu Finituview

The Sartorius YSH34 Filter Holder is a specialized accessory engineered to facilitate the accurate weighing of delicate filters. Its design ensures stable placement and compatibility with the advanced weighing technology of Cubis II balances, thereby optimizing measurement performance.

Sartorius YSH34 Filter Holder, a circular device with a central opening, designed for holding filters on a balance.

Figure 1: The Sartorius YSH34 Filter Holder. This image displays the filter holder, which is a circular accessory with a central aperture, designed to securely hold filters for precise weighing on compatible Sartorius Cubis II balances.

3. Setup Instructions

Follow these steps to properly install the filter holder onto your Sartorius Cubis II balance:

  1. Preparazione: Ensure your Cubis II balance is switched off and unplugged from the power source. Clean the weighing pan area to remove any dust or debris.
  2. Access Weighing Chamber: Carefully open the weighing chamber doors of your Cubis II balance.
  3. Remove Existing Pan (if applicable): If a standard weighing pan is currently installed, gently lift and remove it. Refer to your balance's manual for specific instructions.
  4. Posizione di u Portafiltru: Place the Sartorius YSH34 Filter Holder onto the balance's weighing pan support. Ensure it sits flat and is securely centered. The holder is designed to fit precisely.
  5. Verificate a stabilità: Gently press down on the filter holder to confirm it is stable and does not wobble.
  6. Close Chamber: Close the weighing chamber doors.
  7. Power On: Plug in and switch on your Cubis II balance. Allow it to warm up and perform its self-calibration routine as per the balance's operating manual.

4. Operating Instructions

Once the filter holder is installed, follow these steps for accurate filter weighing:

  1. Tare the Balance: With the filter holder in place and the weighing chamber closed, tare the balance to zero. This compensates for the weight of the holder.
  2. Preparà u filtru: Carefully handle the filter using tweezers to avoid contamination or damage. Ensure the filter is conditioned according to your laboratory's standard operating procedures (e.g., dried, desiccated).
  3. Place Filter: Open the weighing chamber doors and gently place the filter onto the designated area of the filter holder. Ensure the filter lies flat and is centered.
  4. Close Chamber: Close the weighing chamber doors immediately to minimize air currents and environmental influences.
  5. Leghje a misurazione: Wait for the balance reading to stabilize. Record the displayed weight.
  6. Eliminà u filtru: After recording, open the chamber, carefully remove the filter with tweezers, and close the chamber.

5. Mantenimentu

Proper maintenance ensures the longevity and accuracy of your filter holder.

6. Risoluzione di prublemi

Vede a tavula quì sottu per i prublemi cumuni è e so suluzioni putenziali.

IssueCausa PossibileSoluzione
Unstable Balance ReadingsAir currents, vibrations, or improper seating of the holder/filter.Ensure weighing chamber doors are closed. Check for external vibrations. Re-seat the filter holder and filter.
Filter Not Sitting FlatFilter creased or improperly placed.Carefully re-position the filter using tweezers. Ensure the filter is not damaged.
Inaccurate WeighingBalance not tared, contamination, or damaged holder.Tare the balance before placing the filter. Clean the holder and filter. Inspect holder for damage.

7. Specificazioni

Key technical specifications for the Sartorius YSH34 Filter Holder:

SpecificazioneDetail
Tipu d'accessoriSupportu di filtru
Compatible BalancesSartorius Cubis II Ultra-Micro and Micro Balances
Diametru di filtruFinu à 50 mm
MaterialePLA (Polylactic Acid), PE (Polyethylene)
Pesu di l'articulu1.2 liri (circa)
U fabricatoreCOLE-PARMER (as listed by retailer)

8. Garanzia è Support

For warranty information, technical support, or service inquiries regarding your Sartorius YSH34 Filter Holder, please contact Sartorius customer service or your authorized Sartorius distributor. Keep your purchase receipt and product details readily available when contacting support.

You can typically find contact information on the official Sartorius websitu o per mezu di u rivenditore da quale u pruduttu hè statu acquistatu.

Documenti cunnessi - YSH34

Preview Manuale d'uso Sartorius CP Gemplus : Istruzioni per Bilance Analitiche e di Precisione
Guida completa alle istruzioni per l'usu delle bilance elettroniche Sartorius CP e Gemplus (modelli CPA, GCA, GPA). Copre installazione, u funziunamentu, i parametri, u mantenimentu è e specifiche tecniche.
Preview Manuale d'usu di e bilance di laboratorio Sartorius Secura, Quintix, Practum
This user manual provides comprehensive instructions for Sartorius Secura®, Quintix®, and Practum® laboratory balances. It details installation, operation, calibration, maintenance, and various weighing applications, ensuring optimal performance and accuracy for laboratory professionals.
Preview Catalogu cumpletu Sartorius: Soluzioni di meccatronica è pesatura di laburatoriu
Esplora u catalogu cumpletu Sartorius chì presenta mecatronica di laburatoriu avanzata, strumenti di pesatura di precisione, analizzatori di umidità, apparecchiature di elettroanalisi è soluzioni di metrologia di massa per applicazioni scientifiche è industriali.
Preview Sartorius Cubis MCA Operating Instructions: Comprehensive Guide
Official operating instructions for Sartorius Cubis MCA semi-micro, analytical, and precision balances. Learn about device features, installation, operation, safety, and maintenance.
Preview Sartorius CP | Gemplus Series: Operating Instructions for Precision Balances
Comprehensive operating instructions for Sartorius CP | Gemplus Series electronic micro-, analytical, and precision balances, including CPA, GCA, and GPA models. Covers installation, operation, configuration, and maintenance.
Preview Sartorius CP | Bilance Elettroniche Serie Gemplus - Istruzioni per l'usu
Istruzzioni operative cumplete per e bilance elettroniche micro, analitiche è di precisione Sartorius CP | Gemplus Series, cumpresi i mudelli CPA, GCA è GPA. Copre l'installazione, u funziunamentu, a cunfigurazione, i prugrammi d'applicazione, a risoluzione di i prublemi, a manutenzione è e specifiche.