Star 025191 High Performance Pool Pump, a black pump unit with a clear strainer lid and various connection ports.

Image: Star 025191 High Performance Pool Pump. This image displays the complete pool pump unit, highlighting its compact design and key components like the motor, pump housing, and transparent strainer lid.

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Star 025191 High Performance Pool Pump. This pump is designed for use with in-ground or above-ground swimming pools up to 53,000 gallons, ensuring water clarity and hygiene. Please read this manual thoroughly before installation and operation.

The Star 025191 pump features a 1.5 HP single-speed motor, factory-wired for 230 Volts, and is constructed from corrosion-resistant thermoplastic for durability. It delivers a high volume flow rate of up to 110 GPM at 20’ TDH for efficient water circulation to filtration systems.

Importanti Istruzzioni di Sicurezza

Quandu si stallanu è si usanu stu equipamentu elettricu, e precauzioni basi di sicurezza sò sempre seguite, cumprese i seguenti:

  • Leghjite è seguite tutte e struzzioni.
  • PERICOLU: Risk of electrical shock. Connect only to a grounded receptacle protected by a ground-fault circuit interrupter (GFCI).
  • ATTENZIONE: Per riduce u risicu di ferite, ùn permettenu micca i zitelli à aduprà stu pruduttu.
  • ATTENZIONE: This pump is for permanent installation only. Do not use with storable pools.
  • Assicuratevi chì l'alimentazione elettrica currisponde à u vulume di a pompatage requirements (115V or 230V). The pump is factory-wired for 230V.
  • All wiring must be performed by a qualified electrician and comply with local codes and regulations.
  • Always disconnect power to the pump before servicing or performing maintenance.
  • Do not operate the pump if it has been damaged in any way.
  • Keep all connections dry and away from water.

Cuntenutu di u pacchettu

Verificate chì tutti i cumpunenti sò presenti in u pacchettu prima di principià l'installazione.

Diagram showing the pool pump and its included accessories: two 2-inch slip union adapters, two 1.5-inch slip union adapters, and two couplings.

Image: Package Contents Diagram. This illustration details the main pump unit (A) and the included connection accessories: 2-inch slip union adapters (B), 1.5-inch slip union adapters (C), and couplings (D).

Cumpunenti inclusi
ArticuluDescrizzioneQuantità
AStar 025191 Pool Pump1
B2" Slip Union Adapters2
C1.5" Slip Union Adapters2
DAccoppiamenti2

Installazione è installazione

Proper installation is crucial for the pump's performance and longevity. Refer to the installation diagram and follow these steps carefully.

1. Selezzione di u situ

  • Install the pump as close to the pool as possible to minimize friction loss from long suction lines.
  • Ensure the pump is installed on a firm, level base that can support its weight and prevent vibration.
  • Provide adequate ventilation around the motor for cooling.
  • Protect the pump from excessive moisture and direct sunlight.

2. Plumbing Connections

The pump is designed to connect to either 1.5-inch or 2-inch pipe using the included slip union adapters and couplings.

  1. Apply thread sealant to all threaded connections to ensure a watertight seal.
  2. Connect the appropriate slip union adapters (1.5" or 2") to the pump's inlet and outlet ports.
  3. Use the couplings to connect the pump to your existing pool plumbing. Ensure all connections are tight to prevent air leaks, especially on the suction side.
Diagram illustrating the installation of a pool pump with an in-ground pool, showing connections to the skimmer and return lines, and a performance table.

Image: Installation Diagram and Performance Data. This image provides a visual guide for connecting the pump to an in-ground pool system and includes a table detailing the pump's flow rate (GPM) at various Total Dynamic Head (TDH) levels.

3. Cunnessioni elettriche

The Star 025191 pump is factory-wired for 230 Volts. If your electrical supply is 115 Volts, consult a qualified electrician for proper rewiring. The pump includes a 3 ft pigtail cord with ring terminals for connection.

  • Ensure the power supply is disconnected at the circuit breaker before making any electrical connections.
  • Connect the pump's pigtail cord to a dedicated circuit protected by a Ground-Fault Circuit Interrupter (GFCI).
  • All electrical connections must comply with national and local electrical codes.

Istruzzioni di funziunamentu

1. Avviamentu di a pompa

Before starting the pump for the first time, or after the pump has been drained, it must be primed.

  1. Assicuratevi chì u livellu di l'acqua di a piscina sia adeguatu.
  2. Aprite tutte e valvole di aspirazione è di ritornu in u sistema idraulicu di a piscina.
  3. Remove the transparent strainer cover and fill the strainer basket housing with water until it overflows.
  4. Replace the strainer cover, ensuring it is securely tightened to prevent air leaks.
  5. Turn on the power to the pump. The pump should begin to draw water and expel air from the return lines.
  6. If the pump does not prime within 5 minutes, turn it off, re-prime, and check for air leaks in the suction line.

2. Operazione Normale

  • Once primed, the pump will operate continuously, circulating water through your filtration system.
  • Monitor the pressure gauge on your filter (if applicable) to ensure it is within the normal operating range. An unusually high pressure reading may indicate a dirty filter or blockage.
  • Regularly check the transparent strainer cover to see if the basket needs cleaning.

Mantenimentu

Regular maintenance ensures optimal performance and extends the life of your pool pump.

1. Cleaning the Strainer Basket

The large strainer basket is designed to collect debris before it reaches the pump impeller. The transparent cover allows for easy visual inspection.

  1. Turn off the pump and disconnect power at the circuit breaker.
  2. Rotate the transparent strainer cover counter-clockwise to remove it.
  3. Lift out the strainer basket and empty any collected debris.
  4. Sciacquate bè u panaru cù acqua.
  5. Inspect the O-ring on the strainer cover for cracks or wear. Replace if necessary.
  6. Place the clean basket back into the housing, ensuring it is seated correctly.
  7. Replace the strainer cover, tightening it clockwise until snug. Do not overtighten.
  8. Re-prime the pump as described in the "Operating Instructions" section.

2. Preparazione per l'inguernu

Sè vo campate in una zona induve e temperature scendenu sottu à zero, una preparazione adatta per l'inguernu hè essenziale per prevene danni.

  • Spegne a pompa è scollega l'alimentazione.
  • Drain all water from the pump by removing the drain plugs (if applicable) or by disconnecting plumbing.
  • Store the pump in a dry, protected area, or cover it securely if it must remain outdoors.

Risoluzione di prublemi

This section addresses common issues you might encounter with your pool pump. For problems not listed here, contact customer support.

PrublemuCausa PossibileSoluzione
A pompa ùn principia miccaNo power; tripped circuit breaker/GFCI; faulty motor.Check power supply; reset breaker/GFCI; consult electrician.
Pump runs but does not prime or moves little waterAir leak in suction line; low water level; clogged strainer basket; closed valves.Check all connections for leaks; ensure adequate pool water level; clean strainer basket; open all valves.
Rumore eccessivo o vibrazioneAir leak; cavitation; worn bearings; debris in impeller.Check for air leaks; ensure proper water flow; contact service for worn parts.
L'acqua scorri da a pompaCunnessione allentate; guarnizioni/O-ring usurate; alloghju crepatu.Tighten connections; replace O-rings/seals; contact service for housing damage.

Specificazioni

Detailed technical specifications for the Star 025191 High Performance Pool Pump.

Diagram showing the dimensions of the pool pump in inches, along with a table of specifications including weight, motor HP, Hertz, Volts, TagAmp, Phase, Discharge Size, Flow, Impeller Type, Cord Length, Cord Type, and Thermal Protection.

Image: Product Dimensions and Specifications. This image provides a detailed technical drawing with key dimensions of the pump and a table summarizing its electrical and performance characteristics.

SpecificazioneValore
Numero di mudellu025191
Cavalli (HP)1.5 HP
Tipu di MotoreVelocità unica
Voltage115/230V (Factory wired for 230V)
Fase1
Flussu (Max)110 GPM @ 20' TDH (6,000 GPH)
MaterialeCorrosion-resistant Thermoplastic
Dimensione di Scaricamentu1.5" or 2" (adapters included)
Lunghezza di u cordone3 ft pigtail with ring terminals
Prutezzione termale
Dimensioni generale26.5" x 9.45" x 12.6"
PesuCirca 50 lbs (22.6 kg)
UPC054757100056

Garanzia

The Star 025191 High Performance Pool Pump is covered by a Garanzia limitata di 1 anni da a data di compra. Questa garanzia copre i difetti di materiali è di fabricazione in cundizioni d'usu è di serviziu nurmali.

For warranty claims or to understand the full terms and conditions, please refer to the warranty card included with your product or contact Star Water Systems customer support.

Note: This product is not available for shipment to California.

Assistenza Clienti

For technical assistance, replacement parts, or warranty inquiries, please contact Star Water Systems customer support.

  • Websitu: www.starwatersystems.com (Esampu ligame, u ligame attuale pò varià)
  • Telefonu: Cunsultate l'imballu di u vostru pruduttu o u manuale di u fabricatore. websitu per i numeri di cuntattu attuali.

When contacting support, please have your model number (025191) and date of purchase readily available.