1. Introduzione
This manual provides essential information for the safe and efficient use of the FBT E580-4T0370 Vector Inverter. This device is designed for precise motor control in various industrial applications, including machine tools, textile machinery, cable machinery, petrochemical processing, construction, and transmission systems. It offers advanced features for robust performance and flexible control.
Please read this manual thoroughly before installation, operation, or maintenance to ensure proper functionality and to prevent potential hazards.
2. Informazioni di sicurezza
ATTENZIONE: Failure to follow these safety instructions may result in serious injury or equipment damage.
- Cunsultate u manuale d'istruzzioni prima di l'installazione è di l'operazione.
- Ùn cunnette micca l'alimentazione CA à i terminali di uscita UVW.
- Do not remove any cover while applying power and at least 10 minutes after disconnecting power. Residual voltage pò esse presente.
- Securely ground (earth) the equipment to prevent electrical shock.
- Solu u persunale qualificatu deve eseguisce l'installazione, u cablaggio è a manutenzione.
3. Produttu Finituview

Figura 1: Fronte view of the FBT E580-4T0370 Vector Inverter. This image displays the control panel with an orange LED display, navigation buttons (ESC, MODE, FWD, REV/JOG, STOP), and a rotary encoder for parameter adjustment. The model number E580 and 4T0110 (likely a variant or part of the model series) are visible, along with a safety warning label at the bottom.
Funzioni chjave:
- Strong Torque: 200% start torque at 0Hz under Vector Control (VC), 180% start torque at 0Hz under Sensorless Vector Control (SVC).
- Opzioni di Visualizazione: Standard 5-digit two-line LED panel display with optional LCD keypad.
- Monitoraghju in tempu reale: Intuitive monitoring of nearly a hundred parameters, including electricity usage, running time, input/output voltage and current, and error records.
- Macro Functions: Built-in system and application macros simplify parameter setting.
- Flexible Speed Control: Programmable 16-segment speed running with independent settings for running time, acceleration/deceleration, and direction for each segment.
- Virtual I/O: Software virtual I/O function for flexible configuration, reducing external interference and simplifying wiring.
- Prutezzione cumpleta: Abundant warning and protection functions ensure operational safety.
4. Setup è Installazione
4.1. Requisiti Ambientali
- Install in a clean, dry, and well-ventilated area.
- Avoid direct sunlight, corrosive gases, dust, and metallic particles.
- Ensure ambient temperature and humidity are within specified limits (refer to full specifications).
4.2. Muntà
Mount the inverter vertically on a sturdy, non-flammable surface. Ensure adequate clearance around the unit for proper heat dissipation and ventilation.
4.3. Cablu
Tuttu u cablaggio deve esse realizatu da un elettricista qualificatu in cunfurmità cù i codici elettrici lucali è naziunali.
- Ingressu di putenza (R, S, T): Cunnette l'alimentatore AC 380V à i terminali d'entrata designati.
- Uscita di u mutore (U, V, W): Connect the motor leads to the output terminals. Ùn cunnette micca l'alimentazione CA à questi terminali.
- Messa à terra (PE): Connect the protective earth (ground) terminal to a reliable ground point. This is critical for safety.
- Cablaggio di cuntrollu: Connect control signals (e.g., start/stop, speed reference, fault relays) to the appropriate control terminals as per your application requirements. Refer to the detailed wiring diagrams in the complete product manual.
5. Operating Instructions
5.1. Accensione iniziale
After completing all wiring and safety checks, apply power to the inverter. The display panel should illuminate, indicating the inverter is ready for operation.
5.2. Funzionamentu Basic
- Start: Press u FWD button for forward rotation or REV/JOG for reverse rotation (if configured).
- Stop : Press u STOP button to halt motor operation.
- Ajustimentu di Velocità: Use the rotary encoder or external control signals to adjust the motor speed.
5.3. Setting Parameter
The inverter features a user-friendly interface for parameter configuration. Use the MODE button to navigate through menus and the ESC button to exit. The rotary encoder allows for value adjustment.
- Accessing Parameters: Press MODE to enter the parameter menu.
- Navigazione: Use the up/down arrows or rotary encoder to scroll through parameter groups and individual parameters.
- Modifying Values: Select a parameter, press MODE to edit, adjust the value, and press MODE di novu per salvà.
- Macro Functions: Utilize built-in system and application macros to quickly configure common settings. Refer to the detailed parameter list in the full manual for specific macro codes.
5.4. Advanced Control
- 16-Segment Speed Running: Configure up to 16 distinct speed segments, each with independent running time, acceleration, deceleration, and direction settings. This is ideal for complex motion profiles.
- Virtual I/O: The software virtual I/O function allows for flexible configuration of input/output logic without additional physical wiring, simplifying system integration.
6. Mantenimentu
Regular maintenance ensures the longevity and reliable operation of your FBT E580-4T0370 Vector Inverter.
- Disconnection d'energia: Always disconnect all power sources and wait at least 10 minutes before performing any maintenance to allow capacitors to discharge.
- Pulizia: Pulite periodicamente l'esternu di l'inverter è l'aperture di ventilazione per impedisce l'accumulazione di polvere, chì pò impedisce u raffreddamentu. Aduprate un pannu dolce è asciuttu. Ùn aduprate micca detergenti liquidi.
- Ispezione: Regularly inspect wiring connections for tightness and signs of damage or corrosion. Check for any unusual noises or odors during operation.
- Verificazione di u ventilatore: Assicuratevi chì i ventilatori di raffreddamentu funzionanu currettamente è chì sianu liberi da ostaculi.
7. Risoluzione di prublemi
This section provides general guidance for common issues. For detailed troubleshooting, refer to the complete product manual.
| Prublemu | Causa Possibile | Soluzione |
|---|---|---|
| L'inverter ùn si accende micca | No input power; Blown fuse; Wiring error. | Verificate l'alimentazione elettrica; Ispettate i fusibili; Verificate i cunnessione di i fili. |
| U mutore ùn viaghja micca | Incorrect parameter settings; Motor wiring error; Overload condition. | Verify motor parameters; Check motor wiring; Reduce load or check motor size. |
| Guasto di sovracorrente | Sudden load change; Short circuit in motor or wiring; Incorrect acceleration time. | Check load conditions; Inspect motor/wiring; Increase acceleration time parameter. |
| Overvoltage culpa | Volu di input altutage; Rapid deceleration; Regenerative load. | Verificate l'input voltage; Increase deceleration time; Consider braking resistor if applicable. |
Sè u prublema persiste dopu avè pruvatu ste suluzioni, cuntattate l'assistenza tecnica.
8. Specificazioni
| Parametru | Valore |
|---|---|
| Mudellu | E580-4T0370 |
| Marca | FBT |
| Input Voltage | 380V |
| Valutazione di putenza | 37 kW |
| Tipu di cuntrollu | Vector Inverter (VC, SVC) |
| U fabricatore | FBT |
| Materiale | tile (as per product data) |
| ASIN | B08QW7YVFC |
| Prima Disponibile | 17 di dicembre di u 2020 |
9. Garanzia è Support
9.1. Garanzia infurmazione
Specific warranty terms and conditions for the FBT E580-4T0370 Vector Inverter are typically provided with the product packaging or available from the point of purchase. Please retain your proof of purchase for warranty claims. Warranty coverage generally includes defects in materials and workmanship under normal use.
9.2. Support tecnicu
For technical assistance, troubleshooting beyond this manual, or service inquiries, please contact your authorized FBT distributor or reseller. When contacting support, please have your product model number (E580-4T0370) and purchase details readily available.