RENOGY RMS-DCDC-JP

Renogy RMS-DCDC-JP MPPT Charge Controller Monitor Instruction Manual

Model: RMS-DCDC-JP | Brand: RENOGY

1. Introduzione

The Renogy RMS-DCDC-JP is a high-precision monitor specifically designed for Renogy MPPT charge controllers. It provides a clean and professional interface for monitoring your charging system. This monitor can be flush-mounted and features a backlit LCD display. With its four intuitive buttons, users can easily view critical system information, including charging parameters and error codes. It offers real-time feedback for two battery systems, ensuring you have the most current status of your power setup.

Renogy RMS-DCDC-JP Monitor with and without backlight

Image: The Renogy RMS-DCDC-JP monitor displaying system information, shown with and without its backlight activated.

2. Funzioni chjave

3. Cuntenutu di u pacchettu

Verify that all items listed below are included in your package. If any items are missing or damaged, please contact Renogy customer support.

Contents of the Renogy RMS-DCDC-JP package including monitor, manual, cable, and screws

Image: All components included in the RMS-DCDC-JP product package.

4. Setup è Installazione

4.1 Installazione fisica

The RMS-DCDC-JP monitor is designed for flush mounting. Ensure you have adequate space behind the mounting surface for the monitor's body and cable connections. Use the provided mounting screws to secure the monitor in place.

Esplosu view of the Renogy RMS-DCDC-JP monitor showing internal components and casing

Image: Exploded diagram illustrating the monitor's components, including the PVC board, ABS resin covers, and high-resolution display.

4.2 Cunnessione elettrica

Connect the monitor to your Renogy DCC charge controller using the supplied RJ45 communication cable. Simply plug one end of the RJ45 cable into the monitor's port and the other end into the corresponding port on the DCC charge controller. The monitor will power on automatically once connected.

Renogy RMS-DCDC-JP monitor connected to a DCC charge controller via an RJ45 cable

Image: The RMS-DCDC-JP monitor connected to a Renogy DCC charge controller, showing the RJ45 cable connection.

4.3 Guida video d'installazione

Video: A detailed guide on how to install and connect the Renogy RMS-DCDC-JP monitor to your charge controller.

5. Operating Instructions

5.1 Mustrà Overview

The LCD display provides real-time information about your battery and charging system. The displayed items may vary based on your system's configuration.

Diagram of the Renogy RMS-DCDC-JP monitor display showing various icons and parameters

Image: Detailed breakdown of the monitor's display, indicating icons for solar charging, sub-battery, system error, parameter units, alternator, main battery, and charging status.

5.2 Funzioni di u buttone

The monitor features four buttons for navigation and parameter adjustment.

Renogy RMS-DCDC-JP monitor with labels for its four control buttons

Image: The four control buttons on the monitor: Page Up, Page Down, Previous Page, and Enter/Parameter Setting Key.

5.3 Ajustamentu di i parametri

You can adjust charging current limits for the sub-battery directly from the monitor. This feature allows you to optimize charging based on your battery's specifications and system requirements.

Table showing current limit settings for DCC30S and DCC50S charge controllers via the monitor

Image: Current limit settings for DCC30S and DCC50S models, adjustable via the monitor.

To adjust parameters:

  1. Press u Entre button to access the parameter setting menu.
  2. Aduprà u Up è Giù arrow buttons to navigate through the available parameters (e.g., charging voltage, charging current limit).
  3. Press Entre again to select a parameter for adjustment.
  4. Aduprà u Up è Giù i buttoni freccia per cambià u valore.
  5. Press Entre per cunfirmà u novu valore.
  6. Press u Pagina precedente button to exit the setting menu.

5.4 Operazione finitaview Video

Video: Un overview of the monitor's display and basic operation, including how to navigate through information screens.

6. Specificazioni

Table of technical specifications for the Renogy RMS-DCDC-JP monitor

Image: Technical specifications and dimensions of the RMS-DCDC-JP monitor.

ParametruValore
Specificazioni elettriche5 VDC
Curente di fornitura30 mA
Autoconsumu<1 W
Gamma di temperatura di funziunamentu-20 °C à 45 °C
Voltage Precisione± 0.1 V
Precisione attuale± 0.1A
Dimensioni (L x W x H)70 x 110 x 31.5 mm (2.76 x 4.33 x 1.24 inch)
Pesu62 g (0.14 lbs)
Uscita Voltage12 Volts

7. Cumpatibilità

The Renogy RMS-DCDC-JP monitor is compatible with the following Renogy DCC Charge Controllers:

8. Risoluzione di prublemi

If you encounter issues with your Renogy RMS-DCDC-JP monitor, please refer to the following common troubleshooting steps:

For persistent issues or advanced troubleshooting, please contact Renogy customer support.

9. Mantenimentu

The Renogy RMS-DCDC-JP monitor requires minimal maintenance to ensure optimal performance and longevity.

10. Garanzia è Support

The Renogy RMS-DCDC-JP monitor comes with a Garanzia di u fabricatore di 1 anni. Questa guaranzia copre i difetti in i materiali è a manuvra in usu normale.

For warranty claims, technical assistance, or any product-related inquiries, please contact Renogy customer support through their official website or the retailer where the product was purchased. Please have your product model number (RMS-DCDC-JP) and proof of purchase ready when contacting support.

10.1 Additional Support Videos

Video: Un generale sopraview of Renogy products and their features, which may provide additional context for your system.

Video: Another informational video from Renogy, potentially covering system integration or advanced tips.

Documenti cunnessi - RMS-DCDC-JP

Preview Manuale d'usu di u schermu di monitoraghju Renogy RMS-DCDC per i caricabatterie DC-DC
This manual provides detailed instructions for installing, operating, and troubleshooting the Renogy RMS-DCDC monitoring screen, designed for DC-DC MPPT battery charger series. It covers features, LCD icons, parameter settings, and technical specifications.
Preview Caricatore di batteria integratu Renogy 12V 30A/50A à doppia entrata DC-DC cù MPPT Manuale d'usu
Manuale d'usu per u caricatore di batteria di bordu Renogy 12V 30A/50A à doppia entrata DC-DC cù MPPT. Amparate nantu à l'installazione, u funziunamentu, a logica di carica, a sicurezza è e specifiche tecniche per una gestione efficiente di a batteria in camper, barche è sistemi fora di rete.
Preview Renogy 12V 30A/50A DC-DC On-Board Battery Charger with MPPT User Manual
User manual for the Renogy 12V 30A/50A Dual Input DC-DC On-Board Battery Charger with MPPT. Covers installation, operation, features, safety, technical specifications, and troubleshooting for efficient battery charging in RVs, boats, and off-grid systems.
Preview Manuale d'usu di u schermu di monitoraghju Renogy RMS-DCDC per i caricabatterie DC-DC
Comprehensive user manual for the Renogy RMS-DCDC monitoring screen, covering installation, operation, features, troubleshooting, and technical specifications for DC-DC MPPT battery chargers. Includes detailed guides on setup, parameter settings, and error code resolution.
Preview Manuale d'usu di u schermu di monitoraghju Renogy RMS-DCDC
Manuale d'usu per u schermu di monitoraghju Renogy RMS-DCDC, chì furnisce informazioni dettagliate nantu à l'installazione, u funziunamentu, l'icone LCD, a risoluzione di i prublemi è e specifiche tecniche per i caricabatterie DC-DC MPPT.
Preview Caricatore di batteria integratu Renogy 12V 30A/50A à doppia entrata DC-DC cù MPPT Manuale d'usu
Stu manuale d'usu furnisce struzzioni cumplete per u caricatore di batteria integratu Renogy 12V 30A/50A à doppia entrata DC-DC cù MPPT (mudelli RBC30D1S ​​è RBC50D1S), chì coprenu l'installazione, u funziunamentu, e precauzioni di sicurezza, a risoluzione di i prublemi è e specifiche tecniche.