ResMed AirFit F30

Manuale d'istruzzioni di u sistema di telaio ResMed AirFit F30

Model: AirFit F30

Importante infurmazione di sicurezza

Magnetic Interference Warning:

Keep the mask magnets at a safe distance of at least 6 inches (150 mm) away from implants or medical devices that may be adversely affected by magnetic interference. This warning applies to you or anyone in close physical contact with your mask. The magnets are located in the frame and lower headgear clips, with a magnetic field strength of up to 400mT. While designed to connect securely, they may inadvertently detach during sleep.

Contraindications:

Masks with magnetic components are contraindicated for use by patients, or anyone in close physical contact with the patient while using the mask, who have the following:

  • Active medical implants that interact with magnets (e.g., pacemakers, implantable cardioverter defibrillators (ICD), neurostimulators, cerebrospinal fluid (CSF) shunts, insulin/infusion pumps).
  • Metallic implants/objects containing ferromagnetic material (e.g., aneurysm clips/flow disruption devices, embolic coils, stents, valves, electrodes, implants to restore hearing or balance with implanted magnets, ocular implants, metallic splinters in the eye).

Product Overview

The ResMed AirFit F30 Frame System is designed for use with the ResMed AirFit F30 full-face CPAP mask. This system provides a relaxed fit and is intended to support sleep apnea therapy. It features a minimal-contact design, positioning the cushion under the nose, which can be beneficial for individuals who wear glasses, watch television, or sleep on their side.

ResMed AirFit F30 Frame System, showing the clear mask frame, cushion, and elbow connector.

Image: The ResMed AirFit F30 Frame System, featuring its clear, minimal-contact design with blue accents on the side clips and a white elbow connector.

Cumpunenti

The ResMed AirFit F30 Frame System includes the following components:

  • Sistema di quadru
  • u coddu
  • Full-face mask cushion (designed specifically for the AirFit F30 mask)

Note: The AirFit F30 headgear is not included with this frame system replacement.

Esplosu view of ResMed AirFit F30 mask components, including frame, cushion, elbow, and headgear clips.

Imagine: Un esplosu view illustrating the individual components of the AirFit F30 Frame System, including the frame, cushion, elbow, and headgear clips, separated for clarity.

Installazione è adattazione

To ensure effective therapy and comfort, proper setup and fitting of your AirFit F30 Frame System are essential.

  1. Verificate a taglia di u cuscinu: Verify that you have the correct cushion size for your face. The size is typically indicated on the cushion itself.
  2. Hands holding the ResMed AirFit F30 mask, pointing to the 'Cushion Size M' label.

    Image: Hands holding the AirFit F30 mask, with an arrow pointing to the 'Cushion Size M' indicator on the mask frame, emphasizing the importance of checking the size.

  3. Assembla i cumpunenti: Attach the cushion to the frame system and connect the elbow. Ensure all connections are secure.
  4. Attach Headgear (Not Included): If you are replacing an existing frame system, attach your AirFit F30 headgear to the frame. The magnetic clips on the frame are designed for easy attachment and detachment of the headgear.
  5. Pusiziunà a maschera: Place the mask on your face. The minimal-contact design positions the cushion under your nose, covering both the nose and mouth area without obstructing your field of vision.
  6. Adjust Headgear: Adjust the headgear straps to achieve a comfortable and secure fit. The mask should feel snug but not overly tight. Avoid overtightening, as this can cause discomfort and leaks.
  7. Woman wearing the ResMed AirFit F30 mask, showing proper fit and minimal facial contact.

    Image: A woman wearing the AirFit F30 mask, demonstrating its minimal-contact design and how it sits comfortably on the face, allowing for clear vision.

    Latu view of a woman wearing the ResMed AirFit F30 mask connected to CPAP tubing.

    Imagine: Una parte view of a woman wearing the AirFit F30 mask, showing the connection to the CPAP tubing and the overall profile of the mask during use.

  8. Verificate per e fughe: While your CPAP device is running, check for any air leaks around the edges of the mask. Make minor adjustments to the headgear straps as needed to seal any leaks.

Operazione

Once properly fitted, the ResMed AirFit F30 Frame System operates as part of your full-face CPAP mask setup. Its design is intended to provide comfort during therapy, particularly for users who prefer a mask that does not cover the bridge of the nose. The under-the-nose cushion allows for activities like reading or watching TV before sleep and accommodates side sleepers.

Mantenimentu è Pulizia

Regular cleaning and maintenance are crucial for the hygiene and longevity of your AirFit F30 Frame System.

Daily Care Instructions:

  • Rimpiazzà à i segni di deterioramentu.
  • Se necessariu, asciugate l'esternu di a schiuma cù salviette CPAP o salviette simili senza alcolu.
  • Lay flat on a towel to air dry.

Evitate i seguenti:

  • Ùn espone micca à u sole direttu.
  • Do not put in a dishwasher or washing machine.
  • Do not use alcohol or bleach to clean.
Infographic showing daily care instructions for the AirFit frame system, including what to do and what to avoid.

Image: An infographic detailing the recommended daily care for the AirFit frame system, listing actions to take (replace, wipe, air dry) and actions to avoid (direct sunlight, dishwasher, alcohol/bleach).

Schedule di rimpiazzamentu

It is recommended to replace your AirFit F30 Frame System every 3 months to maintain optimal performance and hygiene.

Segni chì puderia esse ora di rimpiazzà u vostru sistema di quadru:

  • Avete perdite eccessive.
  • A vostra terapia pare menu efficace chè di solitu.
  • Your frame system starts to show wear and tear (e.g., cracks, discoloration, loss of elasticity).
Infographic recommending replacement of the frame system every 3 months and listing signs of wear.

Image: An infographic advising replacement of the frame system every 3 months, accompanied by visual cues and a list of indicators for when replacement is necessary.

Risoluzione di prublemi

If you encounter issues with your AirFit F30 Frame System, consider the following:

  • Excessive Leaks:
    • Re-adjust headgear straps for a snug but not overly tight fit.
    • Inspect the cushion for signs of wear, tears, or improper seating on the frame.
    • Check the elbow connection for secure attachment and any visible damage.
  • Magnets Detaching:
    • Ensure the headgear is correctly attached to the magnetic clips.
    • If detachment occurs frequently during sleep, review your sleeping position or consider if the headgear tension needs minor adjustment.
    • Refer to the Important Safety Information regarding magnetic interference.
  • Elbow Leaks Air:
    • Ensure the elbow is fully and correctly inserted into the mask frame.
    • Inspect the elbow for any cracks or damage that could cause air leakage. If damaged, replace the elbow.

Specificazioni

FeatureDetail
Dimensioni di u produttu6 x 4 x 3 inch
Pesu di l'articulu2.72 once
Numero di mudelluAirFit F30
U fabricatoreResMed
ASINB09V76SDTW

Garanzia è Supportu

For detailed warranty information regarding your ResMed AirFit F30 Frame System, please refer to the documentation provided with your original purchase or contact ResMed directly.

For additional support, product information, or to explore other ResMed products, please visit the official ResMed store:

Visit the ResMed Store

Documenti cunnessi - AirFit F30

Preview ResMed AirFit F30 Full Face CPAP Mask Guida d'utilizatore
User guide for the ResMed AirFit F30 full face CPAP mask, detailing components, assembly, fitting, features like QuietAir technology, and performance specifications.
Preview ResMed AirFit F30i Full Face Mask User Guide and Instructions
Comprehensive user guide for the ResMed AirFit F30i full face mask, covering intended use, contraindications, fitting, cleaning, reassembly, technical specifications, and warranty information.
Preview ResMed AirTouch F20 Full Face CPAP Mask: Features & Fitting Guide
Explore the ResMed AirTouch F20 full face CPAP mask, highlighting its innovative UltraSoft memory foam cushion for superior comfort, breathable seal, and easy fitting. Learn about its modular design, quiet operation, and patient benefits.
Preview Modellu di adattazione è guida di dimensionamentu di a maschera CPAP ResMed AirFit F40
Determinate accuratamente a taglia di u cuscinu di a vostra maschera ResMed AirFit F40 CPAP cù questu mudellu di adattazione stampabile. Include istruzioni è guide visuali per una vestibilità è un cunfortu ottimali.
Preview Guida di adattazione di a maschera faciale integrale ResMed AirFit F20
Una guida per l'adattamentu di a maschera faciale integrale ResMed AirFit F20, cumprese istruzioni è un mudellu stampabile per determinà a taglia curretta di u cuscinu.
Preview ResMed AirFit F10 Full Face Mask User Guide - Instructions and Specifications
Comprehensive user guide for the ResMed AirFit F10 full face mask. Includes instructions for fitting, cleaning, troubleshooting, technical specifications, and component details. Designed for positive airway pressure therapy.