RCYAGO PH-W2839

RCYAGO WiFi Tuya pH ORP Temperature Controller Monitor User Manual

Model: PH-W2839 | Brand: RCYAGO

1. Produttu Finituview

The RCYAGO PH-W2839 is a versatile 3-in-1 monitor designed for comprehensive water quality analysis. It accurately measures pH, Oxidation-Reduction Potential (ORP), and temperature, providing real-time data and control capabilities. Equipped with WiFi connectivity, it integrates with the Tuya app for remote monitoring, data logging, and alarm settings, making it ideal for aquariums, aquaculture, and various water management applications.

RCYAGO WiFi Tuya pH ORP Temperature Controller Monitor with probes and power strip

Figura 1: The RCYAGO WiFi Tuya pH ORP Temperature Controller Monitor, showing the main unit, connected pH, ORP, and temperature probes, and the dual-socket power control strip.

Banner highlighting 3-in-1 pH Monitor features: Accurate Measurement, Wide Applications, Automatic Temperature Compensation

Figura 2: Key features of the 3-in-1 monitor, including accurate measurement, wide application range, and automatic temperature compensation.

2. Cuntenutu di u pacchettu

Verificate chì tutti l'articuli sò presenti in u vostru pacchettu:

  • 1 x WiFi Online pH ORP Temperature Controller Unit
  • 1 x pH Electrode
  • 1 x ORP Electrode
  • 1 x sonda di temperatura
  • 1 x Dual-Socket Power Control Strip
  • Calibration Powders (pH 4.01, pH 6.86/7.0, pH 9.18/10.01, ORP 256mV)
  • 1 x Adattatore d'alimentazione
  • Manuale d'usu
Primu pianu view of the ORP electrode, pH electrode, temperature electrode, and power plug

Figura 3: Detailed view of the high-precision ORP electrode, pH electrode, temperature electrode, and the power plug included with the device.

3. Setup è Installazione

Follow these steps to set up your pH ORP Temperature Controller:

  1. Muntamentu di u Controller: Choose a suitable location near your water body (aquarium, tank, etc.) and mount the main controller unit securely. Ensure it is protected from direct splashes.
  2. Connecting Electrodes: Carefully connect the pH electrode, ORP electrode, and temperature probe to their respective BNC connectors and jack on the main controller unit. Ensure connections are firm.
  3. Connecting Power Control Strip: Plug the dual-socket power control strip into the designated output port on the main controller. This strip will be used to connect external devices (e.g., CO2 solenoid valve, heater) that you wish to control based on pH or ORP levels.
  4. Posizionamentu di a sonda: Submerge the pH electrode, ORP electrode, and temperature probe into the water you intend to monitor. Ensure the sensing parts of the electrodes are fully immersed and positioned to get accurate readings, away from strong currents or air bubbles.
  5. Cunnessione di putenza: Plug the main controller's power adapter into a standard electrical outlet. The device will power on.
  6. WiFi Connection (Tuya App):
    • Download the "Tuya Smart" or "Smart Life" app from your mobile device's app store (iOS or Android).
    • Iscriviti o entre in u vostru contu.
    • Follow the in-app instructions to add a new device. The controller should enter pairing mode automatically or by pressing the WiFi button.
    • Connect the device to your 2.4GHz WiFi network.
Diagram illustrating the connection of the pH ORP Temperature Controller to a CO2 bottle, solenoid valve, power outlet, and an aquarium with probes immersed.

Figura 4: A typical setup diagram showing the controller connected to a CO2 system and probes immersed in an aquarium.

The WiFi pH ORP Temperature Controller connected to a small aquarium, displaying real-time data and showing a mobile phone screen with the Tuya app interface.

Figura 5: The controller in operation, demonstrating WiFi connectivity and real-time data transfer to a mobile application.

4. Calibrazione

Regular calibration ensures the accuracy of your pH and ORP readings. It is recommended to calibrate the device upon initial setup and periodically thereafter.

4.1. Calibration pH

The device supports 3-point pH calibration (pH 7.0, pH 4.01, pH 10.01).

  1. Prepare fresh pH buffer solutions (pH 7.0, pH 4.01, pH 10.01).
  2. Rinse the pH electrode with distilled water and gently blot dry.
  3. Immerse the pH electrode into the pH 7.0 buffer solution.
  4. Press the 'CAL' button under the pH display on the controller. The device will automatically recognize the buffer and calibrate. Wait for the reading to stabilize.
  5. Rinse the electrode again.
  6. Repeat the process for pH 4.01 and pH 10.01 buffer solutions. Ensure to calibrate in ascending or descending order as per device prompts.

4.2. ORP Calibration

The device supports ORP calibration using a 256mV standard solution.

  1. Prepare a fresh 256mV ORP standard solution.
  2. Rinse the ORP electrode with distilled water and gently blot dry.
  3. Immerse the ORP electrode into the 256mV standard solution.
  4. Press the 'CAL' button under the ORP display on the controller. The device will automatically recognize the standard and calibrate. Wait for the reading to stabilize.
Banner showing 3-point pH calibration (pH 4.01, pH 6.86, pH 9.18) and ORP calibration (256mV) with buffer solutions.

Figura 6: Visual guide for the 3-point pH calibration and ORP calibration process using standard buffer solutions.

5. Operating Instructions

5.1. Surviglianza Real-tempu

Once powered on and probes are immersed, the controller's LCD screen will display real-time pH, ORP, and temperature readings. The WiFi indicator will show connection status.

5.2. Tuya App Functionality

The Tuya app provides advanced monitoring and control features:

  • Dati in tempu reale: View current pH, ORP, and temperature readings remotely.
  • Dati storichi: Access daily, weekly, and monthly data logs for trend analysis.
  • Impostazioni d'alarme: Set high and low alarm thresholds for pH and ORP. Receive notifications on your mobile device if values exceed or fall below these thresholds.
  • Creazione di Scene Intelligenti: Create automated rules (smart scenes) within the Tuya app to control connected devices via the power strip. For example, turn on a CO2 solenoid when pH rises above a certain level.
The WiFi pH ORP Temperature Controller displaying readings, alongside a mobile phone showing the Tuya app interface with ORP warning settings and historical data graphs.

Figura 7: The controller's display and the Tuya app interface, demonstrating real-time monitoring and alarm settings.

Banner showing APP ALARM SETTINGS with screenshots of the Tuya app for setting high/low alarm values and creating smart scenes for security and alarm methods.

Figura 8: Illustration of the app's alarm setting capabilities, allowing users to define thresholds and trigger actions.

Banner showing real-time data transmission with options to view daily, weekly, and monthly data, set against a swimming pool background.

Figura 9: The device provides real-time data transmission, allowing users to view historical data trends over various periods.

6. Mantenimentu

Proper maintenance extends the lifespan and ensures the accuracy of your electrodes and controller.

  • Pulizia di l'elettrodi: Regularly clean the pH and ORP electrodes with distilled water to remove any buildup or contaminants. For stubborn deposits, use a mild cleaning solution specifically designed for electrodes, following the manufacturer's instructions.
  • Stoccaggio di l'elettrodi: When not in use, store the pH and ORP electrodes in their protective caps filled with a suitable storage solution (e.g., KCL solution or pH 4 buffer). Never store electrodes dry.
  • Recalibrazione: Calibrate the pH and ORP electrodes regularly, especially if you notice inconsistent readings or after cleaning. The frequency depends on usage and water conditions.
  • Controller Unit: Keep the main controller unit clean and dry. Avoid exposing it to extreme temperatures or direct sunlight.

7. Risoluzione di prublemi

Sè avete prublemi cù u vostru dispositivu, riferitevi à i seguenti prublemi è suluzioni cumuni:

PrublemuCausa PossibileSoluzione
Inaccurate pH/ORP readingsElectrodes are dirty or aged; improper calibration; air bubbles on electrode.Clean electrodes thoroughly; recalibrate the device; gently tap electrodes to dislodge bubbles. Replace electrodes if they are old or damaged.
fallimentu di cunnessione WiFiIncorrect WiFi password; device too far from router; 5GHz WiFi network used; router issues.Ensure correct 2.4GHz WiFi password; move device closer to router; verify router is broadcasting 2.4GHz; restart router and device.
Relay output not triggeringIncorrect alarm settings in Tuya app; device not connected to power strip; external device malfunction.Check and adjust pH/ORP alarm thresholds and smart scene rules in the app; ensure the external device is properly plugged into the control strip and functioning independently.
Temperature reading incorrectTemperature probe not fully immersed or damaged.Ensure the temperature probe is fully submerged; inspect the probe for physical damage.

8. Specificazioni

Detailed technical specifications for the RCYAGO PH-W2839 monitor:

Banner displaying product specifications including range, resolution, and accuracy for pH, ORP, and Temperature.

Figura 10: Overview of the device's measurement ranges, resolutions, and accuracy.

ParametruGammaRisoluzioneAccuratezza
pH0.00pH - 14.00pH0.01 pH± 0.1 pH
ORP-2000mV - +2000mV1mV± 5 mV
Temperature0°C - 50°C (32°F - 122°F)1.0 ° C (0.2 ° F)± 1.0 ° C
  • Alimentazione elettrica: AC 110-240V, 50/60Hz (Specific adapter details may vary)
  • WiFi Standard: 2.4GHz 802.11b/g/n
  • Dimensioni: Approximately 11.1 x 8.11 x 2.99 inches (Controller unit)
  • Pesu: Circa 2.34 libbre

9. Applicazioni

The RCYAGO WiFi Tuya pH ORP Temperature Controller Monitor is suitable for a wide range of water quality monitoring applications, including but not limited to:

  • Aquariums (Freshwater and Seawater)
  • Aquaculture and Fish Tanks
  • Hydroponics and Plant Cultivation
  • Swimming Pools and Spas
  • Domestic Water Quality Testing
  • Laboratory Research and Testing
Collage of images showing the WiFi pH ORP Temperature Controller used in various applications: domestic water, aquarium, fish tank, aquaculture, swimming pool, and laboratory.

Figura 11: The versatility of the monitor across different water quality monitoring scenarios.

An image of a vibrant coral reef aquarium with various fish.
Aquariums
Un aereo view of an aquaculture farm with multiple circular fish pens in a large body of water.
Aquaculture
An outdoor swimming pool with lounge chairs and umbrellas.
Piscines
Two scientists in lab coats working with glassware and equipment in a laboratory setting.
Laboratori

10. Garanzia è Support

This product comes with a standard manufacturer's warranty. For specific warranty terms, duration, and to register your product, please refer to the warranty card included in your package or visit the official RCYAGO websitu.

For technical support, troubleshooting assistance, or any inquiries regarding your RCYAGO WiFi Tuya pH ORP Temperature Controller Monitor, please contact RCYAGO customer service through the contact information provided on their official websitu o in a ducumentazione di u vostru pruduttu.

Documenti cunnessi - PH-W2839

Preview DO-9100 Pen Type Intelligent Dissolved Oxygen Analyzer Instruction Manual
This document provides instructions for the DO-9100 pen type intelligent dissolved oxygen analyzer, covering its features, technical parameters, operation, maintenance, and troubleshooting.
Preview RCYAGO SGW07 Dual Water Timer Manuale d'uso
Manuale d'usu cumpletu per u timer d'acqua duale RCYAGO SGW07. Amparate più nantu à u pruduttuview, specifiche, installazione, prugrammi d'irrigazione automatica, irrigazione manuale, ritardu di pioggia, risoluzione di i prublemi è statu di a batteria per u vostru sistema d'irrigazione di giardinu.
Preview pH-W218 Multi-parameter Water Quality Tester - User Manual & App Guide
Comprehensive guide for the pH-W218 multi-parameter water quality tester, covering specifications, operation, calibration (pH, EC, ORP), and mobile app connectivity via Tuya Smart for remote monitoring and alarms.
Preview Manuale d'usu di u tester di qualità di l'acqua multiparametru yieryi pH-W218
Esplora e caratteristiche, e specifiche è u funziunamentu di u tester di qualità di l'acqua multiparametru WiFi yieryi pH-W218. Amparate cumu calibrà è cunnette vi à l'app Tuya Smart per u monitoraghju remotu.
Preview Manuale d'usu di u tester di qualità di l'acqua multiparametru YIERYI PH-W9909
Comprehensive user manual for the YIERYI PH-W9909 multi-parameter WiFi water quality tester. Learn about its specifications, operation, calibration, and mobile app features for monitoring pH, EC, TDS, Salinity, SG, and Temperature.
Preview Manuale d'usu è guida di u monitor di qualità di l'acqua di l'acquariu Kaktoily 7-in-1
Manuale d'usu cumpletu per u Monitor di a Qualità di l'Acqua di l'Aquariu Kactoily 7-in-1. Amparate nantu à e so caratteristiche, e funzioni di monitoraghju, l'installazione, e procedure di calibrazione per pH, ORP, EC, Salinità, TDS, Gravità Specifica è Temperatura, FAQ di risoluzione di i prublemi è serviziu post-vendita.