Frigga M1E

Frigga M1E Single Use Temperature Data Logger with External Probe User Manual

Model: M1E | Brand: Frigga

1. Introduzione

This manual provides instructions for the proper use and maintenance of the Frigga M1E Single Use Temperature Data Logger with External Probe. This device is designed for accurate temperature monitoring in various applications, particularly within cold chain logistics, medicine storage, and food refrigeration. It records temperature data and generates PDF and CSV reports without requiring special software.

2. Produttu Finituview

The Frigga M1E data logger is a compact, single-use device equipped with an external probe for precise temperature measurement. It features an LCD screen for real-time data display and buttons for operation.

Frigga M1E Single Use Data Logger with labeled components

Image 2.1: Frigga M1E Single Use Data Logger with its key components labeled, including the USB Cover, USB Connector, LED Indicator, LCD Screen, Stop Button, Start Button, Bar Code Label, and External Sensor.

Cumpunenti chjave:

3. Setup

The Frigga M1E data logger is designed for immediate use. No prior setup or charging is required as it comes with a pre-installed, long-lasting CR2450 battery.

  1. Unpack u dispusitivu: Carefully remove the data logger from its packaging.
  2. Sonda esterna: Ensure the external temperature probe is securely connected to the device. The probe is essential for accurate temperature measurement.
  3. Placement: Position the data logger and its external probe in the environment where temperature monitoring is required. Ensure the probe is placed to accurately reflect the temperature of the monitored items.

4. Operating Instructions

4.1 Starting the Data Logger

To begin temperature recording:

Frigga M1E User-friendly Interface showing start and stop instructions

Image 4.1: Visual guide for starting and stopping the Frigga M1E data logger, illustrating the button presses and LED feedback.

4.2 Stopping the Data Logger

To stop temperature recording:

4.3 Work Status Indicators

The LCD screen provides various status indicators:

Frigga M1E Work Status Instruction display modes

Image 4.2: Display modes of the Frigga M1E data logger, including Sleep Mode, Start Delay, Recording Mode, Generating Report, and Stop Mode.

4.4 Retrieving Data Reports

After recording is complete, you can easily retrieve the data:

  1. Remove the USB cover.
  2. Plug the data logger into a standard USB port on any computer.
  3. The device will automatically generate a PDF and CSV report. These files will appear as a removable drive.
  4. Open the PDF report to view a summary, temperature graph, and detailed data table. The CSV file provides raw data for further analysis.
Frigga M1E Auto PDF Report Plug and Play feature

Image 4.3: Illustration of the Frigga M1E's plug-and-play functionality for generating PDF and CSV reports directly from the device when connected to a computer.

Video 4.1: This video demonstrates the physical components of the Frigga M1E data logger, how to initiate recording by pressing the START button, how to stop recording using the STOP button, and the process of plugging the device into a computer to automatically generate and access PDF and CSV data reports.

5. Features

The Frigga M1E data logger offers several features designed for reliable temperature monitoring:

Frigga M1E data logger highlighting its features

Image 5.1: Un sopraview of the Frigga M1E's capabilities, including data analysis, temperature calibration report, IP65 waterproof rating, LED alarm, temperature unit switch, event mark, and zero data loss.

Frigga M1E with CR2450 battery compared to CR2032, illustrating long battery life

Image 5.2: This image highlights the long-lasting battery life of the Frigga M1E, featuring a CR2450 battery.

6. Specificazioni

Frigga M1E Product Parameter details

Image 6.1: Detailed product parameters for the Frigga M1E, including measurement range, accuracy range, and memory capacity.

Frigga M1E Data Logger Specifications
ParametruDetail
Nome di mudelluM1E
Gamma di misurazione-40 °C à 80 °C (-40 °F à 176 °F)
Gamma di precisione±0.5℃ (-20℃ to +40℃); ±1℃ for other ranges
Capacità di memoria14400 letture
ReusabilityUsu unicu
Fonte d'energia1 Lithium Ion CR2450 battery (included)
Tecnulugia di cunnessioneUSB
Tipu di visualizazioneLCD
Funzioni spicialiAlarm, Fast Reading System, High Accuracy, External Probe
Materiale EsternuPlastica
Istruzzioni per a cura di u produttuPulisci Pulì
Pesu di l'articulu11.2 once
Lunghezza di l'articulu4 inch
Usu Indoor / OutdoorInternu

7. Mantenimentu

The Frigga M1E is a single-use device and requires minimal maintenance. Follow these guidelines:

8. Risoluzione di prublemi

If you encounter issues with your Frigga M1E data logger, consider the following:

For further assistance, please contact Frigga customer support.

9. Garanzia è Support

Frigga products are manufactured to high-quality standards. For specific warranty information, please refer to the documentation included with your purchase or visit the official Frigga website. For technical support, troubleshooting assistance, or any inquiries regarding your Frigga M1E data logger, please contact Frigga customer service through their official channels.

Pudete truvà più infurmazioni è dettagli di cuntattu nantu à u Frigga Brand Store on Amazon o di u fabricatore websitu.

Documenti cunnessi - M1E

Preview Frigga T7 Series User Manual - Real-Time Cold Chain Temperature Monitoring
Comprehensive user manual for the Frigga T7 Series temperature data logger. Covers device appearance, display functions, setup, monitoring, stopping, reporting, and important cautions for cold chain logistics.
Preview Manuale d'usu di u registratore di dati di temperatura è umidità FRIGGA V5
Manuale d'usu per u registratore di dati di temperatura è umidità FRIGGA V5, chì detalla e so caratteristiche, u funziunamentu, a cunfigurazione è e funzioni di reporting per a logistica di a catena di u fretu.
Preview Manuale d'usu di u Centru di Dati Frigga V 1.0.0
Manuale d'usu cumpletu per u software Frigga Data Center, chì guida l'utilizatori attraversu l'installazione, a gestione di i dati, a cunfigurazione di i dispositivi, i servizii cloud è e funzioni di cunfurmità per u monitoraghju di a catena di u fretu.
Preview Manuale d'usu di u registratore di dati di temperatura è umidità di a serie FRIGGA V5 Plus
Manuale d'usu cumpletu per u registratore di dati di temperatura è umidità di a serie FRIGGA V5 Plus. Amparate cumu cunfigurà, aduprà è recuperà dati da u vostru registratore per u monitoraghju di a catena di u fretu.
Preview Manuale d'usu di u sensore multisensore in tempu reale Frigga 4G è Wi-Fi 6
Manuale d'usu per u Multisensore in Tempu Reale Frigga 4G & Wi-Fi 6 (Modellu S0), chì detalla e so caratteristiche, u cuntenutu di a scatula, u pruduttuview, struzzioni di cunfigurazione, guida di l'indicatore LED, specifiche tecniche, piazzamentu di u dispusitivu, infurmazioni nantu à a batteria, passi di risoluzione di i prublemi è cunfurmità FCC.
Preview Frigga SV2 Series Smart Active Data Logger User Manual
User manual for the Frigga SV2 Series Smart Active Data Logger, detailing appearance, display functions, operation steps, usage scenarios, and FCC compliance.