JABLOTRON BM-02

JABLOTRON™ Nanny Monitor BM-02 Babyphone User Manual

Model: BM-02 | Brand: JABLOTRON

1. Introduzione

Thank you for choosing the JABLOTRON™ Nanny Monitor BM-02. This device is designed to monitor your baby's breathing movements and provide an early warning in case of irregularities. It is a certified medical device, offering peace of mind for parents. This manual provides essential information for the safe and effective use of your Nanny Monitor BM-02.

JABLOTRON Nanny Monitor BM-02 packaging showing the device and key features.

Figura 1: The product packaging for the JABLOTRON Nanny Monitor BM-02, highlighting its certification as a medical device, early warning capabilities, and ease of operation.

2. Impurtante Information Safety

3. Cuntenutu di u pacchettu

Verificate u cuntenutu di u pacchettu per assicurà chì tutti l'articuli sianu presenti è senza danni:

Contents of the JABLOTRON Nanny Monitor BM-02 package.

Figura 2: Un sopratuttu view of all items included in the JABLOTRON Nanny Monitor BM-02 package, including the main unit, sensor mat, power adapter, and documentation.

4. Setup Guide

Follow these steps to set up your Nanny Monitor BM-02:

  1. Sceglie u locu: Select a stable and flat surface for the crib or bed where the baby will sleep.
  2. Place Sensor Mat: Carefully place the sensor mat directly on the solid base of the crib, under the mattress. Ensure the mat is flat and centered where the baby will lie.
  3. JABLOTRON Nanny Monitor BM-02 sensor mat placed under a crib mattress.

    Figura 3: The sensor mat of the JABLOTRON Nanny Monitor BM-02 correctly positioned underneath a baby's crib mattress.

  4. Connect Main Unit: Connect the cable from the sensor mat to the main Nanny Monitor BM-02 unit. Ensure the connection is secure.
  5. Position Main Unit: Attach the main unit to the side of the crib using the integrated hanger, ensuring it is firmly secured and out of the baby's reach. Alternatively, place it on a stable surface near the crib.
  6. JABLOTRON Nanny Monitor BM-02 attached to a baby crib.

    Figura 4: The JABLOTRON Nanny Monitor BM-02 main unit securely attached to the side of a baby crib.

  7. Power On: Plug the power adapter into the main unit and then into a wall outlet. The device will perform a self-test, indicated by flashing lights.
  8. Testu iniziale: After powering on, place your hand on the mattress above the sensor mat and gently tap or press to simulate breathing movements. The green indicator light should illuminate, confirming detection.

5. Operating Instructions

The Nanny Monitor BM-02 is designed for simple operation. Once set up, it continuously monitors your baby's breathing movements.

Indicatori luminosi:

JABLOTRON Nanny Monitor BM-02 main unit and sensor mat.

Figura 5: The JABLOTRON Nanny Monitor BM-02 main monitoring unit, showing the indicator lights.

Risposta à l'Alarma:

If the red light and audible alarm activate:

  1. Immediately check on your baby.
  2. If the baby is unresponsive, follow your pediatrician's instructions for emergency situations.
  3. If the baby is fine, check the sensor mat placement and ensure no external vibrations are interfering with the monitor.

6. Mantenimentu

Pulizia:

Sustituzione di batterie:

The Nanny Monitor BM-02 uses alkaline batteries (if not solely powered by adapter). When the battery indicator illuminates or flashes, replace the batteries immediately to ensure continuous operation. Refer to the battery compartment for specific battery type and replacement instructions.

7. Risoluzione di prublemi

PrublemuCausa PossibileSoluzione
Alarm sounds frequently without apparent reason.
  • Sensor mat not flat or properly positioned.
  • Mattress too thick or too soft.
  • External vibrations (e.g., washing machine, fan).
  • Baby moved off the sensor mat area.
  • Ensure sensor mat is flat and centered under the baby's sleeping area.
  • Use a mattress with appropriate density (not too thick or soft).
  • Relocate the crib or remove sources of vibration.
  • Ensure baby is positioned over the sensor mat.
Green light not flashing, or orange light is on.
  • Sensor mat not connected properly.
  • Main unit not powered on.
  • Faulty sensor mat or main unit.
  • Verificate tutte e cunnessione di cable.
  • Assicuratevi chì l'adattatore di alimentazione sia ben inseritu è ​​chì l'unità sia accesa.
  • Contact customer support if the issue persists after checking connections.
Nisun putere.
  • L'adattatore di corrente ùn hè micca cunnessu.
  • A presa di corrente ùn funziona micca.
  • Low or dead batteries (if battery operated).
  • Check power adapter connection to unit and wall outlet.
  • Pruvate l'outlet cù un altru dispusitivu.
  • Sustituite e batterie se applicabile.

8. Specifiche tecniche

FeatureDetail
MarcaJABLOTRON
MudelluBM-02
MaterialeSensor Mat
Culore1 Sensor Mat (White)
Dispositivi compatiblesSmartphone (Note: This might refer to app compatibility if available, or general device interaction. Based on product description, it's a standalone monitor.)
Dimensioni di u produttu53,5L x 31,5l x 6,5H cm
Pesu di l'articulu1,75 chilògrammi
Tipu di sensorSensore di pressione
Descrizzione di batterieAlkaline

9. Garanzia è Support

For warranty information and technical support, please refer to the official JABLOTRON websitu o cuntattate direttamente u so serviziu clienti. Conservate a vostra prova d'acquistu per qualsiasi reclamu di garanzia.

JABLOTRON Official Websitu: www.jablotron.com (Please verify the exact support URL on the product packaging or official documentation).

Documenti cunnessi - BM-02

Preview Linee guida di marketing Jablotron per i partenarii cummerciale
Linee guida ufficiali per i partenarii cummerciali di Jablotron nantu à l'usu currettu di a marca Jablotron, loghi, culori è caratteri per mantene a coerenza di a marca è migliurà e cumunicazioni di marketing.
Preview Guida tecnica è d'installazione di u rilevatore di muvimentu PIR PET Bus JA-110P
Guida cumpleta per u rilevatore di muvimentu PIR JABLOTRON JA-110P PET Bus, chì copre l'installazione, e caratteristiche, e specifiche tecniche è l'immunità à l'animali.
Preview Modulu JABLOTRON JA-110N-DIN PG: Installazione è Specifiche Tecniche di l'Alimentazione di u Bus di Rail DIN
Uttene struzzioni d'installazione dettagliate, specifiche tecniche è informazioni di cunfurmità per u modulu JABLOTRON JA-110N-DIN PG, un cumpunente chjave per l'alimentazione di u bus è u cuntrollu di relè in i sistemi d'allarme JABLOTRON.
Preview JABLOTRON JA-110P PET Bus: Rilevatore di muvimentu PIR cù immunità à l'animali | Specifiche tecniche
Specifiche tecniche dettagliate è guida d'installazione per u rilevatore di muvimentu PIR Bus JABLOTRON JA-110P PET. Offre immunità à l'animali domestici, compatibilità cù u sistema BUS è cunfurmità cù EN 50131-3 per applicazioni di sicurezza in interni.
Preview Sirena interna di bus JABLOTRON JA-110A: Installazione è specifiche tecniche
Guida cumpleta à a sirena interna di bus JABLOTRON JA-110A, chì copre e procedure d'installazione, i paràmetri interni, e reazioni di u sistema è e specifiche tecniche dettagliate per i sistemi di sicurezza.
Preview Convertitore IP Jablotron JI-120T per telecamere RTSP: Guida d'installazione è cunfigurazione
Una guida cumpleta per l'installazione è a cunfigurazione di u convertitore IP Jablotron JI-120T per e camere RTSP, chì permette una integrazione perfetta cù u sistema cloud Jablotron per a videosorveglianza.