Sure-Lites APC7RG

Sure-Lites All-Pro APC7RG Combination LED Exit Sign and Emergency Light User Manual

Model: APC7RG

1. Introduzione

This manual provides detailed instructions for the installation, operation, and maintenance of the Sure-Lites All-Pro APC7RG Combination LED Exit Sign and Emergency Light. This unit is designed to meet code requirements for emergency egress lighting in commercial buildings, offering both an illuminated exit sign and emergency lighting with adjustable LED heads.

Eight Sure-Lites All-Pro APC7RG Combination LED Exit Signs and Emergency Lights

Image 1.1: Overview of the Sure-Lites All-Pro APC7RG Combination LED Exit Sign and Emergency Light units.

2. Informazioni di sicurezza

Please read and understand all instructions before installation and operation. Retain this manual for future reference.

  • Sicurezza elettrica: All wiring must be performed by a qualified electrician in accordance with national and local electrical codes. Ensure power is disconnected at the circuit breaker before installation or servicing.
  • Integrità di u produttu: Do not modify or alter the product. Use only manufacturer-specified replacement parts.
  • Locu: This unit is UL certified and damp location listed. Ensure the installation environment is suitable.
  • Batteria: The unit contains a nickel-cadmium battery. Dispose of batteries according to local regulations.

3. Cuntenutu di u pacchettu

Verificate chì tutti i cumpunenti sò presenti prima di principià l'installazione:

  • Sure-Lites All-Pro APC7RG Combination LED Exit Sign and Emergency Light Unit
  • Snap-fit canopy with captive mounting screws
  • Directional chevrons (snap-in/snap-out)
  • Installation hardware (screws, wire nuts)
  • Nickel Cadmium Battery (pre-installed or separate)

4. Setup è Installazione

The APC7RG is designed for easy installation with universal J-box mounting and snap-fit construction, allowing for installation in under 5 minutes.

4.1 Opzioni di muntatura

The unit offers universal surface mounting flexibility and can be configured for:

  • Montu à u tettu
  • Montatura murale
  • End mount

It supports configurable single or double faces.

Diagram showing easy installation features: snap-fit construction, ceiling/wall/back mount, 90 minutes run time, and 17 feet egress coverage.

Image 4.1: Key installation and performance features.

4.2 Cablu

  1. Assicuratevi chì l'alimentazione sia OFF à l'interruttore automaticu.
  2. Connect the unit's wiring to the building's AC power supply (120V) according to local electrical codes.
  3. Secure the unit to the universal J-box using the provided hardware and snap-fit canopy.

4.3 Field Selectable Features

The APC7RG exit face is illuminated with long-lasting LEDs that are field selectable for red or green letters. The unit is pre-set to red letters and can be easily changed to green letters during installation. Snap-in/snap-out directional chevrons (arrows) can also be configured to indicate the direction of egress.

Diagram showing components of the exit sign: selectable single or double faces, snap-in/snap-out directional chevrons, high impact UV resistant housing, nickel cadmium battery, field selectable red or green LEDs and inserts, and long life LEDs.

Imagine 4.2: Esplosa view highlighting field-selectable features and components.

Two images showing the exit sign in different commercial settings, one with red letters and one with green letters, demonstrating the selectable faces feature.

Imagine 4.3: Esempiuample of selectable red or green exit sign faces in commercial environments.

5. Operating Instructions

5.1 Operazione Normale

When AC power is supplied, the LED exit sign will illuminate, and the battery will charge. A power indicator light (usually green) located on the bottom of the exit sign will confirm AC power is present and the battery is charging.

5.2 Operazione d'urgenza

In the event of an AC power failure, the unit will automatically switch to battery backup mode. The exit sign and emergency lights will operate for a minimum of 90 minutes, providing up to 17 feet of emergency egress coverage.

5.3 Testu

A test switch is located on the bottom of the exit sign. Press and hold the test switch to simulate a power outage. The unit should switch to battery power, and the exit sign and emergency lights should illuminate. Release the switch to return to normal operation. Regular testing is recommended to ensure proper functionality.

6. Mantenimentu

  • Batteria: The nickel-cadmium battery is designed for no maintenance. However, it is recommended to perform monthly 30-second functional tests and annual 90-minute discharge tests to ensure the battery holds a charge and the unit operates correctly during an emergency.
  • Pulizia: Pulite l'esterno di l'unità cù un soffiu, damp tela. Ùn aduprate micca detergenti abrasivi o solventi.
  • Ispezione: Periodically inspect the unit for any physical damage or discoloration.

7. Risoluzione di prublemi

Vede a tavula quì sottu per i prublemi cumuni è e so suluzioni.

PrublemuCausa PossibileSoluzione
Exit sign or emergency lights do not illuminate during power outage.Battery not charged or faulty; unit not connected to AC power.Ensure AC power is connected and indicator light is on. Allow 24 hours for initial battery charge. If problem persists, battery may need replacement.
L'indicatore luminoso di putenza hè spenta.No AC power; faulty wiring; indicator light malfunction.Check circuit breaker. Verify wiring connections. Contact a qualified electrician if necessary.
Emergency lights do not stay on for 90 minutes during test.A capacità di a batteria ridutta.Perform a full 90-minute discharge test and recharge. If run time is still insufficient, the battery may need replacement.

8. Specificazioni

Key technical details for the Sure-Lites All-Pro APC7RG unit:

Diagram showing the dimensions of the Sure-Lites All-Pro APC7RG exit sign: 16.57 inches (421mm) length, 2.32 inches (59mm) width, 8.26 inches (210mm) height. Also indicates damp location rating, operating temperature range, selectable faces, UL certification, and T20 compliance.

Imagine 8.1: Dimensioni è certificazioni di u pruduttu.

FeatureDetail
MarcaSure-Lites
Nome di mudelluAPC7RG Case Pack
Part NumberAPC7RG
MaterialeHigh-impact, UV resistant thermoplastic (Polycarbonate)
CuloreWhite finish, Red/Green selectable light
Dimensioni di u produttu (L x W x H)16.57" x 2.32" x 8.26"
Tipu di fonte di luceLED
Numero di fonti di luce2 (emergency heads)
Wattage2.01 watts
Luminosità156 lumens
Voltage120 Volts
Fonte d'energiaCorded Electric
Tipu di batterieNickel Cadmium (NiCAD)
Average Battery Life (Emergency Run Time)minuti 90
Egress CoverageFinu à 17 piedi
Tipu di stallazioneFlush Mount (Universal J-box)
CertificazioniUL 924, NEC, NFPA101, NFPA70, CEC Title 20 compliant, Damp Locu Listed
Pesu di l'articulu21.4 libbre (per un pacchettu di 8)

9. Garanzia è Support

9.1 Garanzia infurmazione

The Sure-Lites All-Pro APC7RG unit comes with a 5-year limited warranty. The NiCad battery carries a seven-year pro-rated warranty. Please refer to the warranty documentation included with your purchase for full terms and conditions.

9.2 Assistenza Clienti

For technical assistance, replacement parts, or warranty claims, please contact Sure-Lites customer support. Contact information can typically be found on the manufacturer's websitu o nantu à l'imballu di u pruduttu.

Documenti cunnessi - APC7RG

Preview Driver LED d'emergenza Sure-Lites EBPLEDL6SF - Specifiche è dati di u produttu
Specifiche dettagliate, caratteristiche è dati d'installazione per u driver LED d'emergenza Sure-Lites EBPLEDL6SF di Cooper Lighting Solutions. Include u pruduttu sopraview, dati tecnichi, certificazioni è disegni dimensionali.
Preview Sure-Lites EBP1400NCX/NCF Emergency Ballast Installation Manual
Comprehensive installation, operation, and maintenance guide for Sure-Lites EBP1400NCX and EBP1400NCF emergency ballasts, detailing safety precautions, wiring diagrams, and lamp cumpatibulità.
Preview Sure-Lites ELX Series LED Exit Sign - Technical Specifications
Detailed technical specifications for the Sure-Lites ELX Series self-powered LED exit signs, including features, construction, code compliance, energy data, and mounting options.
Preview Sistema di Illuminazione d'Emergenza Cunnessu Sure-Lites FirstLink | Cooper Lighting Solutions
Esplora u sistema di illuminazione d'emergenza cunnessu Sure-Lites FirstLink di Cooper Lighting Solutions. Questa brochure detalla e caratteristiche di u sistema, l'hardware, u cuntrollu di l'app è i piani di serviziu cuncepiti per a sicurezza di l'edifici è a conformità à u codice.
Preview Sure-Lites EUX Series Universal Mount Edge-Lit LED Exit Sign Specifications
Detailed specifications for the Sure-Lites EUX Series Universal Mount Edge-Lit LED Exit Sign, including features, ordering information, dimensions, electrical and battery specifications, housing and lens details, and warranty.
Preview Sure-Lites All-Pro APX RG Series LED Exit Sign - Technical Specifications
Detailed specifications for the Sure-Lites All-Pro APX RG Series LED Exit Sign, featuring thermoplastic housing, selectable red or green faces, AC-only or battery backup options, and compliance with UL924 and California Title 20.