ECOELER YWT102

ECOELER YWT102 Countdown Timer Switch User Manual

Model: YWT102

Introduzione

This manual provides comprehensive instructions for the installation, operation, and maintenance of your ECOELER YWT102 Countdown Timer Switch. This in-wall timer switch is designed to automatically turn off connected loads such as lights, ceiling fans, bathroom fans, and heaters after a preset time, contributing to energy savings and convenience. It features multiple preset countdown options and a manual override function.

ECOELER Countdown Timer Switch (Ivory, 2-Pack)

Image: The ECOELER Countdown Timer Switch in Ivory, shown as a 2-pack.

Funzioni di u produttu

  • 8 Pre-Set Options: Offers countdown settings of 1 minute, 5 minutes, 10 minutes, 15 minutes, 30 minutes, 60 minutes, 2 hours, or 4 hours.
  • Override manuale: Allows instant ON/OFF control, overriding any active countdown.
  • Risparmio energetico: Automatically turns off loads, preventing accidental energy waste. Ideal for lights, ceiling fans, bathroom fans, and heaters.
  • Operazione simplice: Features Countdown mode and Constant On mode. Select time with a button press; hold ON/OFF for 5 seconds to activate Constant On.
  • Indicatore LED: An always-on LED light makes the switch easy to locate in low-light conditions.
  • Applicazione larga: Suitable for bathrooms, closets, pantries, garages, laundry rooms, spas, and enclosed patios.
  • Sicuru è Affidabile: ETL listed, supporting LED/CFL, Incandescent (800W), Fluorescent (1200VA) light bulbs, and motors (1/2 HP).
ECOELER Countdown Timer Switch Product Features

Imagine: Dettagliata view of the ECOELER Countdown Timer Switch buttons and LED indicator labels, highlighting its features.

Cuntenutu di u pacchettu

Upon opening your ECOELER Countdown Timer Switch package, you should find the following items:

  • ECOELER YWT102 Countdown Timer Switch
  • Matching Wall Plate
  • Noci di filu
  • Manuale d'istruzzioni d'installazione
ECOELER Countdown Timer Switch Package Contents and Dimensions

Image: The ECOELER Countdown Timer Switch, wire nuts, and face plate, along with product dimensions.

Informazioni di sicurezza

ATTENZIONE: To prevent serious injury or death from electric shock, always turn OFF the power at the circuit breaker or fuse box before wiring. This device is intended for installation in accordance with the National Electric Code and local regulations. Use copper wires only. If you are unsure about any part of these instructions, consult a qualified electrician.

Specificazioni

SpecificazioneValore
MarcaECOELER
Numero di mudelluYWT102
CuloreIvory
Dimensioni di u produttu4.19 x 3.71 x 11.99 cm
Potenza/Wattage1800 watts
MaterialeCopper, Metal, Polycarbonate
Pesu di l'articulu136 g
Modu di funziunamentuOFF-OFF
Valutazione attuale15 Amps
Voltage120 Volts (AC)
Tipu di cuntattuNormalmente Open
Cambia tipuPulsante
TerminalCablaggio

Installazione

Follow these steps carefully to install your ECOELER Countdown Timer Switch. If you are not comfortable performing electrical work, please consult a qualified electrician.

Pre-installazione

  1. Spegne l'alimentazione: Locate your circuit breaker panel and turn off the power to the switch box where you will be installing the timer. Verify that the power is off using a voltagè testatore.
  2. Elimina l'interruttore esistente: Carefully remove the screws holding the existing wall plate and switch. Gently pull the switch out of the wall box.
  3. Identificà i fili: Identify the wires connected to your existing switch. Typically, you will find:
    • Hot Wire: Di solitu neru, porta a putenza da l'interruttore automaticu.
    • Filu di carica: Usually black or red, carries power to the light/fan.
    • Filu neutru: Di solitu biancu. A neutral wire is required for this timer switch.
    • Filu di terra: Usually green or bare copper.

Cunnessioni di cablaggio

Connect the wires from the wall box to the ECOELER Countdown Timer Switch as follows:

Wiring diagram for ECOELER Countdown Timer Switch

Image: Wiring diagram for the ECOELER Countdown Timer Switch, illustrating connections for Load (Red), Hot (Black), Ground (Green), and Neutral (White) wires. Note: Neutral Wire Must Be Required.

  1. Cunnette u Filu rossu from the timer to the Filu di carica from the wall box using a wire nut.
  2. Cunnette u Filu neru from the timer to the Filu caldu from the wall box using a wire nut.
  3. Cunnette u Filu biancu from the timer to the Filu neutru from the wall box using a wire nut.
  4. Cunnette u Filu verde from the timer to the Filu di terra from the wall box using a wire nut.

Post-Installazione

  1. Spinghje cù cura tutti i fili in a scatula murale.
  2. Secure the timer switch to the wall box with the provided screws.
  3. Attach the new wall plate over the timer switch.
  4. Ripristina l'energia: Return to your circuit breaker panel and turn the power back ON.

Istruzzioni di funziunamentu

The ECOELER Countdown Timer Switch offers two primary operating modes: Countdown Mode and Constant On Mode.

Modu Countdown

To activate a countdown:

  1. Press the desired time button (1 Min, 5 Min, 10 Min, 15 Min, 30 Min, 60 Min, 2 Hour, or 4 Hour).
  2. The corresponding LED indicator will illuminate, and the countdown will begin.
  3. The connected load (light, fan, etc.) will turn off automatically once the selected time expires.
  4. To cancel a countdown manually, press the large ON/OFF button at the bottom.

Constant On Mode (Manual Override)

To keep the connected load continuously ON, bypassing the timer function:

  1. Press and hold the large ON/OFF button at the bottom for more than 5 seconds.
  2. The load will remain ON until the ON/OFF button is pressed again to turn it off.
ECOELER Countdown Timer Switch LED Indicators in Dark

Image: The ECOELER Countdown Timer Switch with its LED indicator illuminated, making it visible in a dark environment.

Mantenimentu

The ECOELER Countdown Timer Switch requires minimal maintenance. To ensure optimal performance and longevity:

  • Keep the switch and wall plate clean by wiping with a soft, damp pannu. Evitate detergenti abrasivi o solventi.
  • Assicuratevi chì l'interruttore ùn sia micca espostu à umidità eccessiva o à temperature estreme.
  • Periodically check the connections for any signs of loosening, though this should only be done with the power turned off at the circuit breaker.

Risoluzione di prublemi

If you encounter issues with your ECOELER Countdown Timer Switch, consider the following:

  • L'interruttore ùn risponde micca: Ensure the power is ON at the circuit breaker. Check all wire connections for tightness.
  • Load Not Turning Off: Verify that the switch is not in Constant On mode (manual override). If it is, press the ON/OFF button to turn it off.
  • L'indicatore LED ùn s'allume micca: Check power supply and connections. If the switch is functioning otherwise, the LED might be faulty, but this is rare.
  • Operazione intermittente: Ensure all wire connections are secure. Loose connections can cause inconsistent performance.

Sè i prublemi persistenu dopu avè verificatu sti punti, cuntattate l'assistenza clienti.

Garanzia è Supportu

The ECOELER Countdown Timer Switch comes with a 1 anni di garanzia. For any questions, technical assistance, or warranty claims, please contact ECOELER customer support. You can reach us via email at SUPPORTS@ECOELER.COMAvemu u scopu di risponde à tutte e dumande in 24 ore.

Manufacturer: ECOELER ELECTRIC INC

Documenti cunnessi - YWT102

Preview Manuale d'installazione è d'usu di l'interruttore di luce cù sensore di muvimentu ECOELER YM2108T
Guida cumpleta per l'installazione, u cablaggio, l'aghjustamentu è a risoluzione di i prublemi di l'interruttore di luce cù sensore di muvimentu ECOELER YM2108T. E caratteristiche includenu a rilevazione PIR, u ritardu di tempu è l'impostazioni di u livellu di lux.