BEA 1PC BEA FALCON XL(2-3.5m)

BEA Falcon Industrial Door Sensor User Manual

Model: 1PC BEA FALCON XL(2-3.5m) | Brand: BEA

1. Introduzione

The BEA Falcon is a sophisticated unidirectional motion sensor engineered to optimize the performance of automatic industrial doors. This sensor is designed to detect various targets and can be configured to filter out people, allowing for vehicle-only detection. This capability helps reduce door closing cycles by ignoring cross-traffic, leading to energy savings and improved operational efficiency.

The Falcon XL model, specifically, is suitable for mounting heights between 2 meters and 3.5 meters, providing a typical detection area of 4 x 2 meters. Its robust design ensures immunity against vibrations and environmental interferences, making it ideal for demanding industrial environments.

BEA Falcon XL Industrial Door Sensor

Figura 1: Fronte view of the BEA Falcon XL Industrial Door Sensor. This image shows the compact, black housing of the sensor, designed for robust industrial applications.

2. Funzioni chjave

3. Cumpunenti di u produttu

The BEA Falcon sensor consists of several key components designed for easy installation and reliable operation. Refer to the diagram below for an overview of the main parts.

BEA Falcon XL Sensor Components Diagram

Figure 2: Diagram illustrating the main components of the BEA Falcon XL sensor.

  1. Push Buttons: For basic function adjustments.
  2. Front Face: The primary detection surface.
  3. Radar Antenna: Emits and receives microwave signals.
  4. Angle Indication: Visual indicator for tilt angle adjustment.
  5. Bracket: Mounting hardware for secure installation.
  6. Cable: For power and signal connection.

4. Setup è Installazione

The BEA Falcon XL sensor is designed for straightforward installation. Proper mounting and wiring are crucial for optimal performance and safety. It is recommended that installation be performed by qualified personnel.

4.1 Cunsiderazioni di muntatura

4.2 Cablaggio è Alimentazione

4.3 Configurazione iniziale

Basic functions can be adjusted using the integrated push buttons or a compatible remote control. Refer to the detailed product manual (not provided in this summary) for specific programming steps for features like people filtering and cross-traffic filtering.

BEA Falcon XL Detection Field Diagram

Figure 3: Illustration of the detection fields for the BEA Falcon sensor in an industrial door application. This diagram shows how the sensor can differentiate between pedestrian and vehicle traffic, optimizing door operation.

5. Operazione

Once properly installed and configured, the BEA Falcon XL sensor operates autonomously to detect motion within its defined field. The sensor's LED indicator provides visual feedback on its status.

5.1 Detection Mode

The sensor operates in motion detection mode. It identifies moving objects within its detection zone and triggers the door opening mechanism based on the configured parameters (e.g., presence of vehicles only).

5.2 Indicatori LED

5.3 Optimizing Performance

To ensure optimal performance, regularly verify that the detection field is clear of obstructions and that the sensor's lens is clean. The unidirectional detection and filtering capabilities contribute to efficient door operation and energy conservation.

6. Mantenimentu

The BEA Falcon XL sensor is designed for minimal maintenance due to its robust construction and IP65 rating. However, periodic checks are recommended to ensure continued optimal performance.

No user-serviceable parts are inside the sensor housing. Do not attempt to open or repair the unit yourself. Contact qualified service personnel for any repairs.

7. Risoluzione di prublemi

This section provides basic troubleshooting steps for common issues. For more complex problems, consult a qualified technician.

PrublemuCausa PossibileSoluzione
U sensore ùn rileva micca u muvimentu.No power; obstructed detection field; incorrect sensitivity settings; sensor malfunction.Check power supply and connections. Clear any obstructions. Adjust sensitivity settings. If problem persists, contact support.
Door opens for unwanted traffic (e.g., pedestrians).People filter not activated or incorrectly configured; cross-traffic filter not active.Verify and adjust the people filter and cross-traffic filter settings using push buttons or remote control.
L'indicatore LED ùn s'illumina micca.No power; faulty LED; internal issue.Check power supply. If power is present and LED remains off, the unit may require service.
Intermittent detection.Loose wiring; environmental interference; sensor position shifted.Inspect wiring connections. Ensure sensor is securely mounted and not vibrating. Check for new sources of interference.

8. Specifiche tecniche

ParametruValore
TecnulugiaRadar Doppler à microonde
Frequenza di u Trasmettitore24.150 GHz
Trasmettitore Radiated Power<20 dBm EIRP
Densità di putenza di trasmettitore<5 mW/cm²
Modu di rilevazioneMovimentu
Detection Zone (FALCON XL)4 x 2 m (typical at 30° and field size 9)
Min. Velocità di rilevazione5 cm/s
Corsu Voltage12 V to 24 V AC ±10% (50 - 60 Hz); 12 V to 24 V DC +30% / -10%
Cunsumu Max Power<2 W
Relay di uscitaFree of potential change-over contact
Max. Cuntattate Voltage30 V AC / 42 V DC
Max. Cuntattate u currente1A (resistivu)
Max. Cambiamentu di putenza30 W
Signal LEDRed: detection state, parameter indication; Green: value indication
Mounting Height (FALCON XL)2 m - 3.5 m
Gradu di prutezzioneIP65 (IEC/EN 60529)
Gamma di temperatura-30 °C à +60 °C
Dimensioni (L x H x L)127 mm x 102 mm x 96 mm
Angoli di inclinazione0° to 180° vertical
MaterialiABS and Polycarbonate
Pesu400 g
Lunghezza di u cable10 o 15 m

9. Informazioni di sicurezza

Always observe the following safety precautions during installation, operation, and maintenance of the BEA Falcon XL sensor:

10. Garanzia è Support

For warranty information, technical support, or service inquiries, please refer to the documentation provided with your purchase or contact your authorized BEA distributor. Keep your purchase receipt as proof of purchase.

Documenti cunnessi - 1PC BEA FALCON XL(2-3.5m)

Preview FALCON EX Motion Sensor with Explosion-Proof Housing - User Guide
Comprehensive user guide for the BEA FALCON EX motion sensor with explosion-proof housing, covering technical specifications, installation, operation, settings, and troubleshooting.
Preview Sensore d'apertura unidirezionale Eagle Artek per porte automatiche - Guida per l'utente è specifiche
Guida cumpleta per l'utente per u sensore d'apertura unidirezionale BEA Eagle Artek. Copre l'installazione, e specifiche tecniche, i paràmetri, a risoluzione di i prublemi è a conformità per i sistemi di porte automatiche. Modellu SW 0100 è superiore.
Preview BEA EAGLE ARTEK Unidirectional Opening Sensor User Guide
Comprehensive user guide for the BEA EAGLE ARTEK unidirectional opening sensor for automatic doors, covering technical specifications, installation, settings, and troubleshooting.
Preview FALCON EX Sensor de movimiento con carcasa a prueba de explosiones - Guía del Usuario
Guía del usuario detallada para el sensor de movimiento FALCON EX de BEA, Inc. Cubre descripción del producto, especificaciones técnicas, señales LED, uso del control remoto y botones, consejos de instalación, cableado, dimensiones del campo de detección, configuración, solución de problemas y cumplimiento.
Preview BEA IS40 / IS40 XL Motion and Presence Sensor User Manual
Comprehensive user manual for the BEA IS40 and IS40 XL motion and presence sensors, detailing technical specifications, installation, wiring, sensor angle adjustment, remote control operation, radar and air patterns, setup procedures, and troubleshooting for automatic industrial doors.
Preview BEA IXIO-DT1 Sensore di muvimentu è di presenza per porte scorrevoli automatiche - Manuale d'usu
Guida cumpleta per u sensore di muvimentu è presenza BEA IXIO-DT1, chì copre l'installazione, a cunfigurazione, e specifiche tecniche è a risoluzione di i prublemi per e porte scorrevoli automatiche.