SINOTIMER TM919TK

SINOTIMER TM919TK Astronomical Time Switch User Manual

Wide Voltage 85-265Vac Astronomical Time Switch for Automatic Calculation of Sunrise and Sunset

1. Introduzione

The SINOTIMER TM919TK is an advanced astronomical time switch designed for automatic control of electrical loads based on sunrise and sunset times. It eliminates the need for manual adjustments to account for seasonal changes, providing precise and energy-efficient operation. This device features a wide voltage input range (85-265Vac) and a robust 16A, 3200 Watts capacity, making it suitable for various applications. Its replaceable battery design ensures long-term reliability.

2. Informazioni di sicurezza

Leghjite è capite tutte l'istruzzioni di sicurezza prima di l'installazione è di l'usu. U mancatu rispettu di queste istruzzioni pò causà scosse elettriche, incendi o ferite gravi.

3. Produttu Finituview

The TM919TK Astronomical Time Switch features a clear LCD display and intuitive buttons for programming. Below are key components and their functions.

Fronte view of the SINOTIMER TM919TK Astronomical Time Switch

Figura 3.1: Fronte view of the TM919TK timer, showing the display, control buttons, and wiring terminals.

Latu view of the SINOTIMER TM919TK Astronomical Time Switch with clear protective cover

Figura 3.2: Side view of the TM919TK, illustrating its compact design and the clear protective cover over the buttons.

Latu view of the SINOTIMER TM919TK Astronomical Time Switch showing the battery compartment

Figura 3.3: Side view revealing the replaceable battery compartment, ensuring easy maintenance.

4. Specificazioni

FeatureDetail
MudelluTM919TK
Voltage85-265Vac, 50 / 60Hz
Corrente di Carica Max16 A
Potenza massima di carica3200 Watt
Latitude Setting RangeNorth/South 0 - 70° (Accurate to 1 degree)
Longitude Setting RangeEast/West -180° - 180° (Accurate to 1 degree)
Time Zone Range12 ~ -12 (Positive for Eastern, Negative for Western)
Calendari perpetu2017 à 2042
Settings di u prugramma8 ON/OFF programs (can be astronomical or fixed time)
Formatu di u tempucunversione di 12/24 ore
Dimensioni2.68 x 1.42 x 3.54 inch
Pesu di l'articulu4.2 once

5. Installazione

The TM919TK is designed for DIN rail mounting. Follow the wiring diagram carefully to ensure correct and safe installation.

5.1 Schema di cablaggio

Wiring diagram for SINOTIMER TM919TK Astronomical Time Switch

Figure 5.1: Wiring connections for the TM919TK. Connect the incoming Neutral (N) and Live (L) wires to the 'IN' terminals. Connect the load's Neutral (N) and Live (L) wires to the 'LOAD' terminals.

Impurtante: Always ensure the main power supply is turned off before attempting any wiring. Verify all connections are secure before restoring power.

6. Operating Instructions

This section details how to set up and program your TM919TK Astronomical Time Switch.

6.1 Initial Preparation and Basic Settings

Before programming, ensure the timer is powered on and reset. You will then set the current date, time, and your geographical coordinates (latitude and longitude).

Video 6.1: Demonstrates how to press the "RESET" button to turn on the timer and then set the latitude, longitude, date, and current time. This is the first step in preparing the timer for operation.

  1. Accensione è reset: Press the "RESET" button to activate the timer and clear any previous settings.
  2. Set Latitude/Longitude: Navigate through the settings to input your precise latitude and longitude. This is crucial for accurate sunrise/sunset calculations.
  3. Set Date and Current Time: Adjust the year, month, day, and current time to ensure the timer's internal clock is synchronized.

6.2 Astronomical Function Setting

The astronomical function allows the timer to automatically turn ON/OFF at local sunrise and sunset times, which are calculated based on your set latitude and longitude.

Video 6.2: Illustrates how to set the astronomical function. This includes entering the local sunrise/sunset time and adjusting for any desired advance or delay in the ON/OFF operation.

  1. Press the "P" button to enter the programming mode.
  2. Press the "globe" button (or equivalent) to access the astronomical settings.
  3. You can set the ON/OFF times relative to sunrise/sunset, including options to advance or delay the operation by a specific duration.

6.3 Time Mode Setting (Fixed Programs)

In addition to astronomical settings, you can program up to 8 fixed ON/OFF schedules for specific times of the day.

Video 6.3: Shows how to set fixed time programs. The display will first show the astronomical timer program, then allow setting or clearing of up to 8 ON/OFF programs.

  1. Press the "P" button to cycle through the program settings.
  2. For each program (1 ON, 1 OFF, 2 ON, 2 OFF, etc.), set the desired time and day(s) of the week.
  3. You can set or clear these programs as needed.

6.4 Canceling Programs

If you need to remove a previously set program, follow these steps:

Video 6.4: Demonstrates how to cancel both fixed time programs and astronomical programs. For fixed programs, press "P" then "MANUAL". For astronomical programs, press "P" then the "globe" button until the symbol disappears.

6.4.1 Canceling Fixed Time Programs

  1. Press "P" to enter the time setting mode.
  2. Navigate to the specific program you wish to cancel.
  3. Press the "MANUAL" button to cancel the program.

6.4.2 Canceling Astronomical Programs

  1. Press "P" to enter the time setting mode.
  2. Press the "globe" button (or equivalent) repeatedly until the astronomical symbol disappears from the display, indicating the program is canceled.

7. Mantenimentu

7.1 Pulizia

To clean the device, wipe it with a soft, dry cloth. Do not use abrasive cleaners or solvents, as these may damage the casing o visualizazione.

7.2 Sustituzione di batterie

The TM919TK features a replaceable battery to maintain time and settings during power outages. Sè u screnu diventa scuru o i paràmetri si perdenu spessu, a batteria pò avè bisognu di esse rimpiazzata.

  1. Disconnect Power: Ensure the main power supply to the timer is completely disconnected.
  2. Localizà u compartimentu di a batteria: Refer to Figure 3.3 for the location of the battery compartment on the side of the unit.
  3. Replace Battery: Carefully open the compartment and replace the old battery with a new one of the same type. Observe polarity.
  4. Scompartimentu sicuru: Chiude u compartimentu di a batteria in modu sicuru.
  5. Ripristina l'energia: Reconnect the main power supply and verify the timer functions correctly.

8. Risoluzione di prublemi

PrublemuCausa PossibileSoluzione
U display hè viotu o scuru.No power supply; internal battery low or dead.Check power connections. Replace internal battery (see Section 7.2).
Timer not switching ON/OFF at programmed times.Incorrect programming; manual override active; incorrect current time/date/location.Review programming steps (Section 6). Check if manual mode is active and switch to AUTO. Verify current time, date, latitude, and longitude settings.
Astronomical function is inaccurate.Incorrect latitude/longitude or time zone settings.Double-check and correct latitude, longitude, and time zone settings (Section 6.1).
Cannot enter programming mode.Device may be locked or in an unexpected state.Press the "RESET" button to restart the device. Try pressing "P" again.

9. Garanzia è Support

For warranty information or technical support, please contact SINOTIMER customer service through the retailer where the product was purchased or visit the official SINOTIMER website. Please have your product model number (TM919TK) and purchase details ready when contacting support.

Documenti cunnessi - TM919TK

Preview SINOTIMER TM-610 Interruttore orariu digitale per guida DIN - Manuale d'usu è specifiche
Specifiche dettagliate, schemi di cablaggio è istruzioni operative per l'interruttore orario digitale SINOTIMER TM-610, cuncepitu per u montaggio su guida DIN.
Preview Interruttore temporizzatore digitale LCD HD SINOTIMER Serie TM928 - Manuale d'uso è specifiche
Guida cumpleta à l'interruttori di timer digitale di a serie SINOTIMER TM928, chì copre e caratteristiche, e specifiche, a cunfigurazione è u cablaggio per mudelli cum'è TM919, TM920, TM928, TM928S, TM928R è TM929.
Preview SINOTIMER TM-630A/TM-630S Timer digitale: Caratteristiche è specifiche
Specifiche tecniche dettagliate è caratteristiche per i timer programmabili digitali SINOTIMER TM-630A è TM-630S, cumprese l'alimentazione, l'intervallu di timing, e dimensioni è u cablaggio.
Preview Manuale d'usu di l'interruttore temporizzatore programmabile 3 in 1 SINOTIMER Serie TM920
Manuale d'usu cumpletu per l'interruttore timer programmabile 3 in 1 SINOTIMER Serie TM920, cù funzioni di prugrammazione di 7 ghjorni, impulsi è contu à rovescia. Amparate cumu impostà a data, l'ora, i modi di cuntrollu è l'impostazioni di vacanze.
Preview Manuale d'istruzzioni di u timer elettronicu di 7 ghjorni Sinotimer TM-618
Manuale d'istruzzioni cumpletu per u cronometru elettronicu di 7 ghjorni Sinotimer TM-618, chì detalla e caratteristiche, a prugrammazione, u funziunamentu manuale è l'avvertimenti di sicurezza.
Preview Sinotimer TM-616 Timer programmabile settimanale - Specifiche è funziunamentu
Infurmazioni dettagliate nantu à u timer programmabile settimanale Sinotimer TM-616, cumprese specifiche, funzioni di i buttoni, dimensioni, schemi di cablaggio è gamma di prudutti. Dispone di prugrammazione di 7 ghjorni è capacità di commutazione di 30 A.