1. Produttu Finituview
The CHBMSS TC4M-N4N is a compact and reliable digital temperature controller designed for precise temperature management in various applications. It offers features such as temperature calibration, high-temperature alarm, and selectable cooling or heating modes, ensuring stable and safe operation.

Figure 1: CHBMSS TC4M-N4N Temperature Controller Front Panel
Funzioni chjave:
- Compact and lightweight design for easy integration.
- High reliability for consistent performance.
- Temperature calibration function for accurate readings.
- Audible alarm for high-temperature conditions.
- Selectable cooling or heating control modes.
- Adjustable maximum and minimum temperature limits for safety.
2. Informazioni di sicurezza
Please read all instructions carefully before installation and operation. Failure to follow these instructions may result in equipment damage, personal injury, or improper operation.
- Assicuratevi chì l'alimentazione di l'alimentazione voltage matches the controller's specifications.
- Scollegate l'alimentazione prima di fà qualsiasi cablaggio o manutenzione.
- Install the device in a dry, well-ventilated area, away from direct sunlight, high temperatures, and corrosive gases.
- Ùn operate micca u controller cù e mani bagnate.
- This device is not intended for life-support applications where malfunction could result in injury or death.
3. Installazione è Wiring
3.1 Unpacking
Carefully remove the temperature controller from its packaging. Inspect the device for any signs of damage during transit. Report any damage to your supplier immediately.
3.2 Muntamentu
The controller is designed for panel mounting. Ensure adequate space for ventilation and wiring connections at the rear of the unit.
3.3 Schema di cablaggio
Refer to the wiring diagram provided on the side of the unit or in the included quick start guide for specific connection details. Ensure all connections are secure and correctly polarized.

Figure 2: CHBMSS TC4M-N4N Temperature Controller Side View cù Terminali
- Alimentazione elettrica: Cunnette u volu apprupriatutage to the designated power terminals.
- Input Sensor: Connect your temperature sensor (e.g., thermocouple, RTD) to the sensor input terminals. Observe polarity if applicable.
- Rele di output: Connect your heating or cooling device to the output relay terminals. Ensure the load current does not exceed the relay's rating.
4. Operazione
4.1 Power-Up iniziale
Once wired, apply power to the controller. The display will illuminate, showing the current process value (PV) and set value (SV).

Figure 3: CHBMSS TC4M-N4N Display Example
4.2 Setting the Temperature (SV)
- Press u MODE button briefly to enter the set value adjustment mode. The SV display will flash.
- Aduprà u Su (▲) è Giù (▼) i buttoni freccia per aghjustà a temperatura desiderata.
- Aduprà u Left (◀) arrow button to shift the cursor for faster adjustment of individual digits.
- Press u MODE button again to confirm the setting and exit adjustment mode.
4.3 Impostazioni di i parametri (Avanzate)
To access advanced parameters (e.g., control mode, alarm settings, calibration), press and hold the MODE button for several seconds until the parameter menu appears. Navigate using the arrow buttons and confirm with MODE.
- Modu di Raffreddamentu / Riscaldamentu: Select between cooling (output active when temperature is above SV) or heating (output active when temperature is below SV).
- Calibrazione di a temperatura: Adjust the sensor reading to match a known reference temperature.
- Impostazioni d'alarme: Configure alarm thresholds (AL1, AL2) and alarm types.
- Max/Min Temperature Limits: Set upper and lower bounds for the adjustable temperature range to prevent accidental over/under-setting.
5. Mantenimentu
The CHBMSS TC4M-N4N Temperature Controller requires minimal maintenance to ensure long-term reliable operation.
- Pulizia: Pulite periodicamente u display è casincù un pannu dolce è asciuttu. Ùn aduprate micca detergenti abrasivi o solventi.
- Ispezione: Regularly check wiring connections for tightness and signs of wear or corrosion.
- Ambiente: Assicuratevi chì l'ambiente operativu resti in i limiti di temperatura è umidità specificati.
6. Risoluzione di prublemi
If you encounter issues with your temperature controller, refer to the following common problems and solutions:
| Prublemu | Causa Possibile | Soluzione |
|---|---|---|
| A visualizazione hè in biancu | Nisuna alimentazione o cablaggio sbagliatu. | Verificate i cunnessione di l'alimentazione è assicuratevi di u vulume currettutage. |
| A lettura di a temperatura hè imprecisa | Sensor faulty, incorrect sensor type selected, or calibration needed. | Verify sensor connection, check sensor type setting, perform temperature calibration. |
| Output not activating | Wiring error, control mode incorrect, or temperature not reaching set point. | Check output wiring, verify cooling/heating mode, ensure SV is appropriately set. |
| Allarme sempre attivu | Alarm set point too close to PV, or sensor issue. | Adjust alarm thresholds, check sensor accuracy. |
If the problem persists after attempting these solutions, please contact CHBMSS customer support for further assistance.
7. Specifiche tecniche
| Parametru | Valore |
|---|---|
| Mudellu | TC4M-N4N |
| Marca | CHBMSS |
| Dimensioni di u pacchettu | 1.18 x 0.79 x 0.39 inch |
| Pesu di l'articulu | 1.1 liri (500 grammi) |
| Culore | Un culore |
| U numeru di pezzi | 1 |
| ASIN | B0DPYS4XK7 |
| U fabricatore | CHBMSS |
8. Garanzia è Support
For warranty information or technical support, please refer to the documentation included with your purchase or contact CHBMSS customer service directly. Please have your product model number (TC4M-N4N) and purchase details ready when contacting support.