Tecmojo 18U Wall Mount Server Cabinet

Tecmojo 18U Wall Mount Server Cabinet & 8 Outlet Rack Mount Power Strip Instruction Manual

Model: 18U Wall Mount Server Cabinet

Brand: Tecmojo

1. Introduzione

This manual provides detailed instructions for the assembly, installation, operation, and maintenance of your Tecmojo 18U Wall Mount Server Cabinet and the accompanying 8 Outlet Rack Mount Power Strip. Please read this manual thoroughly before installation and use to ensure proper functionality and safety.

2. Informazioni di sicurezza

  • Always ensure the cabinet is securely mounted to a structurally sound wall capable of supporting the cabinet's weight plus the weight of all installed equipment.
  • Do not exceed the maximum weight capacity of 110 lbs (50 kg) for the cabinet.
  • Ensure all electrical connections are made by qualified personnel and comply with local electrical codes.
  • Do not block ventilation openings on the cabinet. Proper airflow is essential to prevent overheating.
  • Use appropriate personal protective equipment (PPE) during installation, such as gloves and eye protection.
  • Mantene i zitelli è l'animali domestici luntanu da a zona d'installazione.

3. Cuntenutu di u pacchettu

Verificate chì tutti i cumpunenti elencati quì sottu sò presenti prima di principià u montaggio:

  • Pannellu di fondu
  • Top Cover (with fans)
  • Porta di vetru di fronte
  • Front Frame (2 pieces)
  • Rack Rails (4 pieces)
  • Side Panels (2 pieces)
  • Copertina posteriore
  • Fixed Brackets (4 pieces)
  • Scaffale cantilever
  • L parentesi
  • Rotelle (4 pezzi)
  • 8 Outlet Rack Mount Power Strip
  • Assorted Screws, Nuts, and Keys

4. Specificazioni

4.1. 18U Wall Mount Server Cabinet

  • Unità di rack: 18U
  • Materiale: Heavy Duty Cold Rolled Steel
  • Capacità di pesu: Finu à 110 lbs (50 kg)
  • Dimensioni (L x P x A): 21.7" x 17.7" x 34.8" (550 mm x 450 mm x 883 mm)
  • Tipu di muntatura: Wall Mount (also supports floor standing with casters)
  • Porta di fronte: Reversible Locking Tempered Glass Door
  • Pannelli laterali: Lockable and Removable
  • Raffreddamentu: One built-in top fan (expandable with additional fan slot), flow-through ventilation
  • Gestione di Cable: Removable top and bottom panels for easy cable routing, knock-off holes
  • Conformità: Cunforme à EIA/ECA-310-E

4.2. 8 Outlet Rack Mount Power Strip

  • Numero di punti vendita: 8 NEMA5-15R
  • Connettore di input: 1 NEMA 5-15P
  • Valutazione attuale: 15A (12A UL Certified)
  • Voltage: 125 V AC
  • Prutezzione di Surge:
  • Indicatori LED: Ground (Green), Surge (Red)
  • Cordone d'alimentazione: Integrated 6ft power cord
  • Muntamentu: 1U Rack-mountable, fits standard 19" server racks
  • Cambia: Illuminated ON/OFF switch with protective cover
  • Pesu di u produttu: 4 lbs
  • Alloghju: Acciaio Laminatu à Freddu
  • Certificazione: Certificatu UL

5. Assemblea & Installazione

5.1. Server Cabinet Assembly (Floor Standing)

Follow these steps to assemble your server cabinet for floor-standing use. Refer to the provided assembly videos for visual guidance.

  1. Attach Front Frames to Bottom Panel: Secure the two front frame pieces to the vented side of the bottom panel using the provided screws.
  2. Secure Back Cover to Bottom Panel: Attach the back cover to the bottom panel using the appropriate screws.
  3. Pone a Copertura Superiore: Position the top cover onto the assembled frame and fasten it with the provided screws. Ensure all accessories are correctly spliced and secured.
  4. Installa Rack Rails: Install the four rack rails uniformly according to your desired equipment depth. Use the provided screws to fix them in place.
  5. Assembla i pannelli laterali: Attach the left and right side panels in sequence.
  6. Install Front Glass Door: Align the joints, move the bolt, and install the front glass door. Ensure it opens and closes smoothly.
  7. Installa Casters: Invert the rack, fix the bottom panel, and install the four casters using M6 bolts and nuts.

Video: Tecmojo Standard Wall Mount Cabinet Installation Guide. This video demonstrates the step-by-step assembly of the server cabinet, including attaching frames, panels, and installing casters.

Video: Tecmojo Elite 15/18U Wall Mount Server Cabinet Assembly. This video provides a visual guide for assembling the 15/18U cabinet, showing the installation of various components.

5.2. Server Cabinet Wall Mounted Installation

Se preferite u muru, seguite questi passi:

  1. Remove Casters: If casters were installed, remove them.
  2. Fix Wall Mount Bracket: Secure the wall mount bracket to your desired wall location using appropriate screws and anchors (not included, ensure they are suitable for your wall type and the cabinet's weight). A drilling template is included for easy installation.
  3. Hang and Secure Cabinet: Carefully hang the assembled cabinet onto the fixed wall mount bracket. Secure the cabinet to the bracket with additional screws.
Wall mounting hole drilling template and cabinet features

Image: Wall mounting hole drilling template and key features like removable side panels and knock-off holes for cable management.

5.3. Power Strip Installation

The 8 Outlet Rack Mount Power Strip is designed for seamless integration into standard 19" server racks.

  1. Identificà u locu di muntatura: Choose a 1U space within your server cabinet for the power strip.
  2. Secure Power Strip: Align the mounting brackets of the power strip with the rack rails and secure it using appropriate rack screws (typically 10-32 or 12-24, depending on your rack rails).
  3. Connect Power: Plug the integrated 6ft power cord into a suitable wall outlet.
8-Outlet Rack-Mount Power Strip with Surge Protection features

Imagine: Dettagliata view of the 8-Outlet Rack-Mount Power Strip, highlighting its 8 NEMA5-15 outlets and mounting brackets for standard racks.

6. Operazione

6.1. Server Cabinet Fans

The server cabinet includes one built-in top fan for ventilation. This fan helps to prevent overheating of your network equipment by increasing airflow. Additional fans can be installed in the available slots if needed.

6.2. Power Strip

  • Switch di Potenza: The power strip features an illuminated ON/OFF switch with a protective cover. Flip the switch to the 'ON' position to supply power to the outlets.
  • Indicatori LED: The green LED indicates a proper ground connection, while the red LED indicates active surge protection.

6.3. Thermostat (if applicable)

Some models of the Tecmojo Wall Mount Server Cabinet may include a thermostat for fan control. If your model includes this feature, you can set your preferred temperature. The fans will activate automatically when the internal temperature exceeds the set threshold, ensuring optimal cooling.

Video: Wall Mount Server Cabinet with Thermostat. This video demonstrates how to set the thermostat to your preferred temperature for automatic fan control.

7. Mantenimentu

  • Pulizia: Regularly clean the exterior of the cabinet with a soft, dry cloth. For the glass door, use a glass cleaner. Ensure no liquids enter the cabinet.
  • Ispezione di u ventilatore: Periodically check the top fans for dust accumulation. Clean the fan blades gently with a soft brush or compressed air to maintain efficient cooling.
  • Gestione di Cable: Ensure cables are neatly organized and not obstructing airflow or door closure.
  • Meccanismu di serratura: Lubricate the door and side panel lock mechanisms periodically to ensure smooth operation.

8. Risoluzione di prublemi

  • No Power to Power Strip:
    • Check if the power strip's ON/OFF switch is in the 'ON' position.
    • Verify the power cord is securely plugged into a working wall outlet.
    • Verificate l'interruttore automaticu per a presa di corrente murale.
  • Fans Not Operating:
    • Ensure the cabinet is receiving power.
    • If your model has a thermostat, check its settings to ensure the temperature threshold has been met.
    • Inspect fan wiring for any loose connections.
  • Equipment Overheating:
    • Ensure cabinet fans are operating correctly.
    • Check for any obstructions to airflow within the cabinet or at the ventilation openings.
    • Consider installing additional fans if the heat load is high.

9. Garanzia è Supportu

Tecmojo products are designed for reliability and performance. For specific warranty details, please refer to the warranty card included with your product or contact Tecmojo customer support. Our customer service team is available to assist with any questions or issues you may encounter.

Informazioni di cuntattu: Please refer to the product packaging or Tecmojo's official websitu per i dettagli di cuntattu di l'assistenza clienti più recenti.