ACiQ ACiQ-K09W-W-HP230B

Manuale d'usu di u sistema di riscaldamentu/aria condizionata mini split ACiQ 20 SEER2 Essentials 9000 BTU

Model: ACiQ-K09W-W-HP230B

1. Produttu Finituview

This manual provides essential information for the safe and efficient operation of your ACiQ 20 SEER2 Essentials 9000 BTU Mini Split AC/Heating System. This ductless heat pump system is designed to provide both cooling and heating for spaces approximately 250-400 sq. ft. in size, operating on 208/230V power.

Please read this manual thoroughly before installation, operation, or maintenance. Keep it for future reference.

ACiQ 20 SEER2 Essentials Mini Split System components: indoor unit, outdoor unit, remote control, and smartphone displaying the control app.

Imagine: Più diview of the ACiQ Mini Split System, showing the indoor unit, outdoor condenser, remote control, and a smartphone interface for WiFi control.

2. Informazioni di sicurezza

3. Ciò chì hè inclusu

Your ACiQ Mini Split System package includes the following components:

Diagram showing all included components of the ACiQ Mini Split System, numbered and labeled.

Image: A visual representation of all items included in the ACiQ Mini Split package, such as the indoor unit, outdoor unit, line set, remote, and various installation accessories.

  1. Indoor Unit (Air Handler)
  2. Unità Esterna (Condensatore)
  3. Control remoto
  4. 16ft Line Set (pre-charged for this length)
  5. Cappetta da Parete
  6. Drain Lines
  7. Cordi di alimentazione
  8. Ferramenta di muntatura (viti, tasselli)
  9. Batterie AAA (per u telecomandu)
  10. Manuale d'uso (stu documentu)
  11. Additional small parts like rubber feet, plastic wrap, plasticine, and a remote mount.

4. Guidelines Installazione

As stated in the safety information, installation of this ACiQ Mini Split System requires a qualified HVAC professional. The following points are general guidelines and not a substitute for professional expertise.

Nota impurtante: The unit comes pre-charged with refrigerant for up to a 25ft line set. If your line set is shorter, a professional will still need to vacuum the lines. If a longer line set is used, additional refrigerant may be required, which must be added by a certified technician.

5. Operating Instructions

5.1 Operazione di cuntrollu remoto

The remote control allows you to manage all functions of your ACiQ Mini Split System. Insert the provided AAA batteries before first use.

Diagram showing the remote control with icons for various features like I Feel Mode, Sleep Mode, Eco Mode, Mute Mode, Timers, and Turbo Mode.

Image: Remote control features, illustrating icons for I Feel Mode, Sleep Mode, Eco Mode, Mute Mode, Timers, and Turbo Mode.

5.2 WiFi Control (Smart Device App)

Your ACiQ Mini Split System is equipped with built-in WiFi, allowing control via a smart device (iOS or Android) from anywhere. The app is compatible with Amazon Alexa, Google Assistant, and IFTTT.

A person smiling while using a smartphone to control the ACiQ Mini Split system via the Smart Life app, demonstrating WiFi control.

Image: A user operating the ACiQ system remotely via a smartphone app, highlighting the WiFi control feature.

  1. Scaricate l'App: Download the "Smart Life" app from your device's app store (iOS or Android).
  2. Registrazione/Accessu: Create an account or log in to the Smart Life app.
  3. Aghjunghjite u dispositivu: Follow the in-app instructions to add your ACiQ Mini Split System. This typically involves putting the unit into pairing mode (refer to the full manual for specific steps) and connecting it to your home WiFi network.
  4. Cuntrolla: Once connected, you can control all functions of the unit, including mode, temperature, fan speed, and scheduling, from your smartphone or tablet.
  5. Integrazione Smart Home: Link the Smart Life app with Amazon Alexa, Google Assistant, or IFTTT for voice control and advanced automation.

6. Mantenimentu

Regular maintenance ensures optimal performance and longevity of your ACiQ Mini Split System. Always disconnect power to the unit before performing any maintenance.

7. Risoluzione di prublemi

Prima di cuntattà l'assistenza clienti, per piacè riferitevi à i seguenti prublemi è suluzioni cumuni.

PrublemuCausa PossibileSoluzione
L'unità ùn si accende.Nisuna alimentazione, batterie di u telecomandu scariche, interruttore automaticu scattatu.Verificate l'alimentazione elettrica, rimpiazzate e batterie di u telecomandu, resettate l'interruttore automaticu.
Raffreddamentu/riscaldamentu insufficiente.Dirty air filters, blocked outdoor unit, wrong mode selected, temperature setting incorrect, low refrigerant.Clean air filters, clear outdoor unit, select correct mode, adjust temperature, contact professional for refrigerant check.
Fuga d'acqua da l'unità interna.Blocked drain line, improper installation.Check and clear drain line, contact professional for inspection.
Rumore insolitu.Pezzi allentati, ostruzione di u ventilatore, prublema di u compressore.Turn off unit and inspect for obstructions. If noise persists, contact professional.
U cuntrollu remoto ùn funziona micca.Batterie scariche, ostruzione trà u telecomandu è l'unità, malfunzionamentu di u telecomandu.Rimpiazzate e batterie, eliminate l'ostruzioni, pruvate à resettà u telecomandu.

For issues not listed here or if solutions do not resolve the problem, please contact ACiQ customer support or a qualified HVAC technician.

8. Specificazioni

Diagram showing the dimensions of the indoor and outdoor units, along with key specifications like power supply, cooling/heating BTU, SEER2/EER, estimated coverage area, and indoor noise levels.

Image: Technical specifications and dimensions for the ACiQ Mini Split Indoor and Outdoor Units.

FeatureDetail
Numero di mudelluACiQ-K09W-W-HP230B / ACiQ-K09Z-HP230B
Capacità9,000 BTU (0.75 Tunnellata)
SEER2 Efficiency20.0
Alimentazione elettrica230V~ / 60Hz / 1Ph
Gamma operativa di raffreddamentu5°F to 122°F outdoor temperature
Gamma Operativa di Riscaldamentu-4°F to 86°F outdoor temperature
Zona di cupertura stimata250-400 sq ft
Dimensioni di l'unità interna (A x L x P)7.99" x 31.92" x 11.49"
Dimensioni di l'unità esterna (A x L x P)19.60" x 30.98" x 11.41"
Livellu di rumore internuSin'à 28 dBA
Tipu di refrigeranteR454B
Funzioni spicialiBuilt-in WiFi, Ultra-quiet operation, Full installation kit, Heats in -4°F temps

9. Garanzia è Support

ACiQ provides a comprehensive warranty for your peace of mind.

Warranty information graphic showing '6-Year Compressor & 4-Year Parts Warranty' and 'Best in Class Customer Service' with a shield icon.

Image: ACiQ warranty details, indicating 6-year compressor and 4-year parts coverage.

Per piacè cunservate a vostra prova d'acquistu per scopi di garanzia.

Documenti cunnessi - ACiQ-K09W-W-HP230B

Preview ACiQ Essentials Mini-Split Air Handler & Condenser Installation and Owner's Manual
Comprehensive installation and owner's manual for ACiQ Essentials Mini-Split Air Handler and Condenser systems, covering safety precautions, parts identification, remote control operation, installation procedures, test runs, maintenance, and troubleshooting for various models. The manual also includes critical information regarding the servicing of systems using flammable refrigerant R454B, emphasizing safety protocols and regulatory compliance. It is designed for professional installers and end-users to ensure safe and efficient operation of ACiQ mini-split heat pump systems.
Preview ACiQ Standard Single-Zone Mini Split Installation and Owner's Manual
Comprehensive guide for installing and operating ACiQ Standard Single-Zone Mini Split air conditioning systems. Covers safety precautions, unit specifications, installation procedures, maintenance, and troubleshooting.
Preview Manuale di serviziu di a cassetta di soffittu sottile ACiQ è di u condensatore Platinum
Manuale di serviziu per l'unità ACiQ Slim Ceiling Cassette è Platinum Condenser, chì detalla a sicurezza, l'installazione, a manutenzione è a risoluzione di i prublemi per i mudelli SCC è ACIQ-ZPL.
Preview Sistemi monozona ACiQ 9K-24K Standard Heat: Manuale d'installazione è di u pruprietariu
Manuale d'installazione è di pruprietà di i sistemi monozona di riscaldamentu standard ACiQ 9K-24K. Questa guida detalla l'installazione, u funziunamentu, a sicurezza è a manutenzione di i climatizzatori ACiQ, cumprese e specifiche di u mudellu è l'infurmazioni nantu à u refrigerante R454B.
Preview Manuale d'installazione di u condensatore à zona unica ACiQ Extreme Heat è di u trattatore d'aria à condotti nascosti
Manuale d'installazione per i sistemi di condensazione à zona unica ACiQ Extreme Heat è di gestione di l'aria à condotti nascosti (mudelli da ACIQ-09CD-HH-MC à ACIQ-60CD-HH-MC è da ACIQ-09ZPL-HP230C à ACIQ-60ZPL-HP230C). Include i passi di sicurezza, d'installazione è e specifiche.
Preview Manuale d'installazione è di u pruprietariu di u trattatore d'aria murale ACiQ è di u condensatore à zona unica per calore estremu
Stu manuale furnisce linee guida dettagliate per l'installazione, u funziunamentu è a sicurezza per i trattatori d'aria murali ACiQ è i condensatori à zona unica per calore estremu, chì coprenu i mudelli ACIQ-06W-HH-MD finu à ACIQ-24ZPL-HP230C.