ENTTEC 73539 DIN PIXIE
Informazione di u produttu
Specificazioni:
- Guida di Creazione di Protocolli Personalizzati
- Compatible with ENTTEC pixel controllers: DIN PIXIE, PIXELATOR MINI, PIXELATOR MINI MK2, OCTO MK2, OCTO MK3
- Firmware Version Requirements: V1.0 or above for some models, V2.0 or above for others, V4.0 or above for OCTO MK2
Istruzzioni per l'usu di u produttu
Introduzione:
ENTTEC Pixel controllers support over 20 default pixel protocols. The custom protocol feature allows users to create a custom protocol for pixel fixtures not covered by default protocols without the need for new firmware.
Requisiti di stallazione:
- Datasheet of the desired pixel fixture
- Computer to access the device settings page
- For ENTTEC Ethernet Controller: Device IP address (DHCP or static)
- For DIN PIXIE: EMU Software for configuration
Guide to Custom Protocol Creation:
- Verify datasheet for compatible pixel protocol
- Navigate to the Device’s User Interface to enablethe custom protocol feature
- Adjustthe pixel fixture’s data voltage timing viathe web interface based othe n datasheet
Step 1: Verify Datasheet for Compatible Protocol
- Check the data transmission method from the datasheet
- Identify data transmission method (e.g., D1-D2-D3…Dn or C1-C2-D1-D2…Dn)
- Choose a supported protocol with a similar data transmission method
FIRMWARE COMPATIBILE
A creazione di protokollu persunalizata hè presentata in i seguenti controller di pixel ENTTEC:
| SKU | Pruduttu | Versione Firmware |
| 73539 | DIN PIXIE | V2.0 o altru |
| 70067 | PIXELATOR MINI | V2.0 o altru |
| 70068 | PIXELATOR MINI MK2 | V1.0 o altru |
| 71521 | OCTO MK2 | V4.0 o altru |
| 71522 | OCTO MK3 | V1.0 o altru |
INTRODUZIONE
- ENTTEC Pixel controllers support more than 20 pixel protocols by default. In the event of missing protocol, this custom feature allows users to create a custom protocol for the desired pixel fixture anytime without having to submit a support request for new firmware.
- Sta funziunalità permette utilizatori à aghjustà u voltagU timing basatu annantu à i protokolli supportati se u metudu di trasmissione di dati currisponde à qualsiasi di i nostri protokolli supportati.
- Stu documentu furnisce struzzioni di installazione per creà un protocolu di pixel persunalizatu è verificate i criteri.
REQUISITI DI SETUP
I seguenti sò necessarii per creà un protokollu persunalizatu:
- Scheda dati: Obtain the datasheet of the desired pixel fixture to gather necessary information. Contact the dealer or manufacturer for this document.
- Dispositivu: Use a computer to access the device settings page.
- For the TEC Ethernet Controller: Obtain the device IP address, which can be either DHCP or static, based on your network settings. Discover the IP using the ENTTEC EMU app.
- For DIN PIXIE: Use the EMU Software for configuration.
GUIDA PER A CREAZIONE DI PROTOCOLLI PERSONALIZZATI
Sta funziunalità permette utilizatori à aghjustà u vol datitage timing to meet specific protocol needs. To create a custom protocol:
- Verificate a datasheet per u protocolu di pixel compatible.
- Navigate à l'Interfaccia d'Usuariu di u Dispositivu per attivà a funzione di protokollu persunalizata.
- Aghjustate i dati di u pixel fixture voltage timing via u web interfaccia cum'è a datasheet di u fabricatore.
Passu 1: Verificate a datasheet per u protocolu compatible
- Verificate u metudu di trasmissione di dati di u vostru protokollu desideratu da a datasheet.
- The data transmission method implies how the data is forwarded. Below are demonstrated the common data transmission methods:
- U metudu più cumuni trasmette dati senza bit supplementari (per esempiu, D1-D2-D3… Dn).
Example: Informazioni catturate da a datasheet di WB2812B
- Certi protokolli, cum'è TM1814, includenu dati supplementari in fronte (per esempiu, C1-C2-D1-D2... Dn).
Example: Informazioni catturate da a datasheet di TM1814
- U metudu più cumuni trasmette dati senza bit supplementari (per esempiu, D1-D2-D3… Dn).
- The data transmission method implies how the data is forwarded. Below are demonstrated the common data transmission methods:
- Nominate u protokollu currispundente supportatu da u dispusitivu (o sceglite da l'example) that shares the same data transmission method as your desired pixel protocol.
- Avanzate à u Passu 2 per più cunfigurazione.
Step 2: Navigate to the Device’s Settings page to enable the custom protocol feature
In this step, the OCTO/PIXELATOR MINI Series and Din PIXIE are guided accordingly due to their distinct interfaces.
For ENTTEC Ethernet Controllers (OCTO/PIXELATOR MINI Series)
- Access to the OCTO/PIXELATOR MINI web interfaccia
- Google Chrome hè suggeritu cum'è web browser to access the OCTO/PIXELATOR MINI’s web interfaccia.
- Free ENTTEC app, EMU can be used to discover OCTO/PIXELATOR MINI’s IP address. See the ENTTEC websitu www.enttec.com per scaricà l'app.
- After entering the IP address of OCTO/PIXELATOR MINI, the user will land on the Home page of OCTO/PIXELATOR MINI’s User Interface.

Example of the OCTO homepage in Figure 1 indicates IP address 10.10.3.31, which was assigned by the DHCP server. For the out-of-box OCTO/PIXELATOR MINI that is connected directly to a computer (no DHCP server), the default IP address is 192.168.0.10.
See OCTO/PIXELATOR MINI User Manual ‘Networking’ section for more information.
- Navigate to the Settings page – Output Setting.
Andà à l'output induve l'apparechju di pixel desideratu hè cunnessu. Sceglite un protokollu di pixel da a lista dropdown chì sparte u stessu metudu di trasmissione verificatu in u Passu 1.
- Enable Custom protocol (Continue to Step 3)
Attivà a scatula 'Custom' tick à accede à i dati voltage cunfigurazione di u timing. Spuntate per disattivà u protocolu persunalizatu.
Per DIN PIXIE
- Cunnette DIN PIXIE à un urdinatore cù USB Type-B.
- Lanciate u software EMU.
- Scan per u dispusitivu è cliccate nant'à u Conf di u scupertu DIN PIXIE.

- Enable Custom Protocol (Continue to Step 3)
Pick a pixel protocol from the dropdown list that shares the same transmission method verified in tp,1, and enable Custom.
Passu 3: Set vol customizatatage timing
- Abbinate u voltage timing nantu à a datasheet di u vostru protocolu desideratu. Protokollu Custom hà bisognu di 4 inputs per compie i dati voltage regolazione di u timing:
Voltage Timing Definition Bit 0 High Time (T0H) U voltagU tempu altu necessariu per u codice 0. Bit 1 High Time (T1H) U voltagU tempu altu necessariu per u codice 1. Overall Bit Time: U voltu tutaletage time for a single bit. Lower limit = T0H+T0L
Upper limit = T1H+T1L
Reset Time U voltu tutaletagE pocu tempu necessariu per resette a trasmissione di dati trà ogni batch di dati. 
- Datasheet - Dati voltage timing info Example
Da a scheda di dati WB2818B- Locate the ‘Sequence Time’ table in WB2818B’s datasheet for the voltage intervallu di timing.
- Riempi u voltage intervallu di timing in u campu persunalizatu in Settings Output.

IMPORTANTE
- ENTTEC recommends taking the median value of the range for the start.
- L'utilizatore duverà SAVE i paràmetri per chì u valore mudificatu sia effettu.
- Fine adjustment of value required, followed by actual output test to optimise custom protocol for pixel fixture control.
- ENTTEC recommends a trial run on the actual setup before finalising the custom protocol setup.
- Typical issues of incorrect setup include, including and not limited to, failure to light up and output flickering.
CONCLUSIONE
- Questa guida hà dimustratu cumu stabilisce un protokollu persunalizatu per i dispositi ENTTEC eligibili è hà furnitu cunniscenze tecniche per verificà a scheda di dati di i vostri apparecchi di pixel desiderati.
- Facendu questi passi, l'utilizatori ponu creà un protokollu di pixel persunalizatu chì ùn hè micca truvatu in a lista drop-down senza aspittà di supportu tecnicu o una nova versione di firmware. Sì avete dumande o difficultà à truvà l'infurmazioni ghjusta, ghjunghje à a nostra squadra di supportu amichevule in l'uffizii lucali.
FAQ
How do I access the device settings page on my computer?
You can access the device settings page by connecting your computer to the device's network and entering the IP address in a web navigatore.
Can I create a custom protocol without the datasheet?
It is recommended to have the datasheet to ensure accurate customization of the protocol based on the pixel fixture's specifications.
Documenti / Risorse
![]() |
ENTTEC 73539 DIN PIXIE [pdfManuale d'istruzzioni DIN PIXIE, PIXELATOR MINI, PIXELATOR MINI MK2, OCTO MK2, OCTO MK3, 73539 DIN PIXIE, 73539, DIN PIXIE, PIXIE |