Introduzione di u produttu

This Multi-Soil MT-01 Soil Sensor can monitor soil at different depths in real-time. By measuring the dielectric constant of the soil, this Multi-Soil MT-01 sensor can directly and stably reflect the true moisture content of various soils, and is the internationally standard method of measuring soil moisture. Apply to water-saving in farming, checking the weather, monitoring the environment, growing flowers and vegetables in greenhouses, grassy fields, soil testing, plant cultivation, scientific experiments, and more.

Features:

Soil moisture content, electrical conductivity, and temperature all in one.
Multi-layer monitoring. Supports 4 layers of soil temperature & moisture & EC monitoring.
High-quality plastic shell. Anti-aging and resistant to corrosion from acid and alkali in the soil.
Tight waterproof treatment. It can be immersed in water for a long time without leakage.
Reliable performance. Measurement accuracy is high, less affected by soil salinity, and applicable to various soil types.
Multi-directional imitation misconnection protection. With the power line, ground line, and signal line, there is multi-directional anti-wrong connection protection.

Specificazione

Temperatura di u Terrenu
Gamma -30 ~ 70 ℃
Accuratezza ± 0.5 ℃
Risoluzione 0.1 ℃
Umidità di a terra
Gamma 0 ~ 70 %
Accuratezza ± 3 %
Risoluzione 0.1 %
Conduttività elettrica
Gamma 0 ~ 5000 μs/cm
Extensible customization range:
0 ~ 20000 μs/cm
Accuratezza ± 10 %
Risoluzione 10 μs / cm
Parametri Generali
Interfaccia RS-485
Protocolu MODBUS-RTU RS485
Puntu di misurazione 10cm (4 in)
20cm (8 in)
30cm (12 in)
40cm (16 in)
Area di misurazione Within 10cm outside the surface
Tempu di risposta <100 ms
Tempu di Start-up 10 seconds after powering on
Alimentazione elettrica 12V ~ 24V
Cunsumu attuale 12V / 40mA
24V / 20mA
Temperature di funziunamentu -10 ℃ ~ 55 ℃
Classificazione IP IP68
Lunghezza di u cable 10 metri
Pesu di u dispusitivu 1505 g

Hardware finituview

Wiring

Wiring

Wiring Connettore Aviazione Filu di Sensore Descrizzione
1 VCC+ DC12-24V
2 NC Micca cunnessione
3 RS485 A
4 RS485 B
5 GND Terra

Dimensioni

Dimensioni

Installazione

Set monitoring locations: 

Use an earth auger to drill holes at suitable locations, then remove impurities from the removed earth, rub it fine, and add water to make a slurry.
Set monitoring locations

Grouting installation:

Slowly pour the mud into the hole and turn the sensor down slowly in one direction. Until some of the mud is spilled and the 0 scale line is level with the ground surface.
Grouting installation

Avvisu: Installation should be done slowly, do not pull the sensor upwards to avoid air entering the hole and affecting the measurement.

Wait for mud to stabilize:

After completing the installation, it is necessary to wait for a period of time til the slurry has stabilised and returned to its normal state before starting monitoring.

Protocollo Modbus RS485

Protocolu Modbus

Modbus Protocol is widely used to establish master-slave communication between intelligent devices or sensors. A MODBUS message sent from a master to a slave contains the address of the slave, the function code (e.g. ‘read register’ or ‘write register’), the data, and a checksum (LRC or CRC).

Multi-Soil MT-01 sensor with RS485 interface supports Modbus protocol. The communication parameters to factory default values for: Baud rate 9600 bps, one start bit, 8 data bits, no parity, one stop bit.

Communication protocol is Modbus RTU protocol. Communication parameters can be changed by the setup program or MODBUS command, after the communication parameters are changed, the sensor is required to re-enter the sensor to be effective.

Following modbus function code are supported by sensor:

Modbus Function Code 0x03: used for reading holding register.
Modbus Function Code 0x04: used for reading input register.
Modbus Function Code 0x06: used for writing single holding register.
Modbus Function Code 0x10: used for writing multiple

Registri Modbus

Nome di u paràmetru Registru Indirizzu Tipu di Paràmetru Modbus Function number Gamma di Parametri è Descrizzione
Soil Temperature (10cm) 0x0000 / 0 INT16, leghje 3/4 -32768-32767 Divide by 10 to get the true value Unit: ℃
Soil Moisture (10cm) 0x0001 / 1 UINT16, leghje 3/4 0-1000 Correspond to0-100%
Soil EC (10cm) 0x0002 / 2 UINT16, leghje 3/4 0-500 Correspond to0-5000μs/cm
Terra
Temperature
(20 cm)
0x0003/3 INT16, leghje 3/4 -32768-32767
Divide by 10 to get the true value
Unit: C
Umidità di a terra
(20 cm)
0x0004/4 UINT16, leghje 3/4 0-1000
Correspond to 0-100%
Soil EC
(20 cm)
0x0005/5 UINT16, leghje 3/4 0-500
Correspond to 0-5000
μs/cm
Terra
Temperature
(30 cm)
9/9000 × 0 INT16, leghje 3/4 -32768-32767
Divide by 10 to get the true value
Unit: “C
Soil Moisture (30cm) 0x0007/7 UINT16, leghje 3/4 0-1000
Correspond to 0-100%
Soil EC (30cm) 0x0008 / 8 UINT16, leghje 3/4 0-500
Correspond to 0-5000
μs/cm
Soil Temperature (40cm) 0x0009/9 INT16. read 3/4 -32768-32767
Divide by 10 to get the true value
Unit: ‘C
Umidità di a terra
(40 cm)
0x000A/10 UINT16, leghje 3/4 0-1000
Correspond to 0-100%
Soil EC (40cm) 0x000B/11 UINT16, leghje 3/4 0-500 Correspond to 0-5000 μs/cm
Slave ADDRESS 0x0100 / 256 UINT16, Read/Write 3/6/16 0-255 Default is 49(Dec)

Lettura di Dati Sensor

Reads data (soil temperature, soil moisture, soil EC) from the sensor (address 49, decimal)

Master Send:

31 03 0000 000C 403F (CRC Checksum)

Sensor Response: 

31 03 18 00D3 (Soil Temperature-10cm) 0110 (Soil Moisture-10cm) 0028(Soil
EC-10 cm) 00D0 (Soil Temperature-20cm) 0121 (Soil Moisture-20cm) 0032(Soil
EC-20 cm) 00CD (Soil Temperature-30cm) 012E (Soil Moisture-30cm) 003C(Soil
EC-30 cm) 00CB (Soil Temperature-40cm) 0138 (Soil Moisture-40cm) 0041(Soil
EC-40 cm) 62D9 (CRC Checksum)

Data representation: 

Soil Temperature: INT16 format, divide by 10 to get real value in C
Umidità di a terra: UINT16 format, divide by 10 to get real value in %(m³/m³)
Soil EC: UINT16 format, multiply by 10 to get the true value in µs/cm

Per esample, the data above indicates that:

10 cm: Soil Temperature: 21.1℃, Soil Moisture: 27.2%(m³/m³), Soil Soil EC: 400 μs/cm;
20 cm: Soil Temperature: 20.8°C Soil Moisture: 28.9%(m³/m³) – Soil EC: 500 μs/cm;
30 cm: Soil Temperature: 20.5°C, Soil Moisture: 30.2% * ((m ^ 3) / (m ^ 3)) Soil EC: 600 μs/cm;
40 cm: Soil Temperature: 20.3°C, Soil Moisture: 31.2%(m³/m³), Soil EC: 650 μs/cm;

Modify Modbus Address

Set default Modbus address (49 in decimal) to 02:

Slave Adr Codice di Funzione Register Addr H Register Addr L Register Data H Register Data L CRC16
H
CRC16
L
31 06 01 00 00 02 0C 07

Repeat the sent command if the sensor successfully receives and modifies the address.

Avvisu: Make sure that only one slave is connected when using the broadcast address to modify the sensor address.

Versione di documentu

Versione Data Descrizzione Editore
V1.0 1/24/2025 Prima edizione LeoLiu

Assistenza Clienti

Logo © 2008-2025 Seeed Technology Co., Ltd. Tutti i diritti riservati. www.seeedstudio.com.cn
LogoLogo

Documenti / Risorse

SENSECAP MTEC-01B Sensore di Terrenu Multiprufundità [pdfManuale d'usu
MTEC-01B Sensore di Terrenu Multiprufundità, MTEC-01B, Sensore di Terrenu Multiprufundità, Sensore di Terrenu di Prufundità, Sensore di Terrenu

Referenze

Lascia un cumentu

U vostru indirizzu email ùn serà micca publicatu. I campi obbligatori sò marcati *